# Amperis Products S.L. > Test and diagnostic equipment for substations: thermal cameras, micro-ohmmeters, power analyzers, and transformer and circuit breaker testing. CIF B27352830. ## This site in other languages - [Español](https://amperis.com/) - [Français](https://amperis.com/fr/) - [Português](https://amperis.com/pt/) - [Italiano](https://amperis.com/it/) - [Deutsch](https://amperis.com/de/) ## Data for agents and programs - [catalogo.json](https://amperis.com/en/catalogo.json): full catalogue in JSON (name, URL, description, category, datasheet and translations of each product) - [llms-full.txt](https://amperis.com/en/llms-full.txt): full text of every product page in a single file - [mcp.amperis.com](https://mcp.amperis.com/mcp): MCP server of the catalogue: search and lookup tools for AI assistants ## Main pages - [Company](https://amperis.com/en/about/) - [Resources](https://amperis.com/en/resources/) - [Contact](https://amperis.com/en/contact/) ## Product categories - [BAC: industrial battery charger](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/battery-charger-bac/): BAC battery charger for backup systems in substations and industry: stable, reliable charging of stationary battery banks. - [Battery chargers and rectifiers](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/): Industrial chargers and rectifiers for substation battery banks: stable float charging, 110/125 V DC systems and alarms, sized per IEEE 485. - [Battery maintenance, charging & testing](https://amperis.com/en/products/battery-maintenance-and-charging/): Amperis battery maintenance and charging for substations: chargers, dischargers, capacity and impedance testers; IEEE 450/1188 and IEC 60896. - [Circuit breaker test equipment & analysers](https://amperis.com/en/products/switch-testing/switch-testing/): Amperis circuit-breaker analysers for substations: timing, travel, static and dynamic contact resistance and coil current; IEC 62271, IEEE C37.09. - [Corona Effect Cameras](https://amperis.com/en/products/cameras/corona-effect-cameras/): Corona cameras that reveal UV discharge on insulators, overhead lines and substations in full daylight. Vendor of high-voltage inspection equipment. - [Dielectric test sets for insulating PPE](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/): Amperis dielectric test sets for insulating PPE: withstand testing of gloves, sleeves, blankets, mats and sticks; IEC 60903, 60984, 61112, 61111. - [Nexus Series: power quality meters](https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/): Nexus Series power quality and energy meters for substations: high-accuracy energy metering, disturbance analysis and IEC 61850. - [SF6 leak detectors for switchgear & GIS](https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/): Amperis SF6 leak detectors for substations: sniffer and optical gas imaging for GIS and breakers, supporting EU F-gas leak-check duties (2024/573). - [Transformer winding ohmmeters](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/): Micro-ohm winding resistance meters for transformers: IEC 60076-1 testing, OLTC continuity per IEC 60214-1 and automatic core demagnetisation. - [2.5 kV insulation testers for motors & cables](https://amperis.com/en/products/insulation-resistance-meters/25kv/): Amperis insulation resistance testers up to 2.5 kV for substations and industry: motor windings, cables, switchgear, PI and DAR diagnostics. - [Battery dischargers for capacity testing](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/): Constant-current battery dischargers for capacity tests to IEEE 450, 1188 and 1106: portable BLU units up to containerised high-power systems. - [Infrared cameras for electrical inspection](https://amperis.com/en/products/cameras/infrared-camaras/): Radiometric infrared cameras for substations and industry: hot-spot detection under load, ISO 18434-1 thermography and NETA MTS severity criteria. - [Microhmmeters](https://amperis.com/en/products/switch-testing/microhmmeters/): Microhmmeters for contact and joint resistance at test currents up to hundreds of amps. Vendor of DC resistance test equipment to IEEE and NETA. - [SF6 gas analysers: purity, moisture, SO2](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/): Amperis SF6 gas analysers for substations measure purity, moisture and SO2 by-products with measure-and-return, per IEC 60376 and IEC 60480. - [Shark Series: energy and power meters](https://amperis.com/en/products/electric-panel-multimeters/serie-shark/): Shark Series energy meters and network analyzers for electrical monitoring and submetering in substations and industry. - [Transformer ratio meters (TTR)](https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/): Amperis transformer ratio meters (TTR) for substations: turns ratio, polarity, phase and tap-changer checks; IEC 60076-1 (±0.5%), IEC 61869. - [Transformers Testing](https://amperis.com/en/products/transformers-testing/): Transformer testing: turns ratio, winding resistance, oil quality and tan delta. Vendor of transformer diagnostics to IEC 60076 and IEEE C57. - [5 kV insulation testers for MV cables & motors](https://amperis.com/en/products/insulation-resistance-meters/5kv/): Amperis insulation resistance testers up to 5 kV for substations: MV cables, motors, transformers, dielectric discharge and step-voltage tests. - [APQM Series: power quality analyzers](https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/): APQM Series power quality analyzers measuring harmonics, flicker and voltage events to EN 50160 in networks and substations. - [Battery testers: internal resistance & voltage](https://amperis.com/en/products/battery-maintenance-and-charging/battery-testers/): Amperis battery testers for substations: internal resistance, impedance, conductance and cell voltage on VLA and VRLA strings; IEEE 1188 and IEEE 450. - [Coil testers for breakers & contactors](https://amperis.com/en/products/switch-testing/coil-testing/): Amperis coil testers for substations: trip and close coil current signature, resistance and minimum pickup voltage; IEC 62271-1 and IEC 62271-100. - [SF6 gas recovery & handling equipment](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/): Amperis SF6 recovery and handling units for substations evacuate, filter, store and refill gas without emissions; IEC 62271-4 and the EU F-gas Regulation. - [Testing and checking of switches](https://amperis.com/en/products/switch-testing/): Circuit-breaker testing: timing, contact resistance, coil analysis and SF6 gas quality. Vendor of switchgear test equipment to IEC 62271 standards. - [10 kV insulation testers for HV substations](https://amperis.com/en/products/insulation-resistance-meters/10kv/): Amperis insulation resistance testers up to 10 kV for substations: generator stators, HV cables, transformers, GIS and high noise immunity; IEEE 43. - [Infrared & corona effect cameras](https://amperis.com/en/products/cameras/): Amperis infrared and corona-effect cameras for substations: detect hot spots and HV surface discharge for predictive maintenance; ISO 18434-1. - [SF6 gas analysis, leak detection & handling](https://amperis.com/en/products/switch-testing/sf6/): Amperis SF6 equipment for substations: gas analysers, leak detectors and recovery units for GIS and breakers, per IEC 60376/60480 and EU F-gas. - [15 kV insulation testers for HV & EHV assets](https://amperis.com/en/products/insulation-resistance-meters/15kv/): Amperis insulation resistance testers up to 15 kV for substations: large generators, EHV cables, GIS and HV apparatus above 34.5 kV, per ANSI/NETA. - [Partial Discharge Detection](https://amperis.com/en/products/partial-discharge-detector/): Partial discharge detection for cables, switchgear and transformers. Vendor of PD measurement and continuous monitoring equipment to IEC 60270. - [Protection relay test equipment](https://amperis.com/en/products/relay-testing/): Relay test sets for substations: three-phase secondary injection, pickup and timing tests to IEC 60255, IEEE C37.90 and NETA ATS tolerances. - [Insulation resistance meters 1 to 15 kV](https://amperis.com/en/products/insulation-resistance-meters/): Megohmmeters from 1 to 15 kV for cables, transformers and motors: PI and DAR per IEEE 43, IEC 61557-2 and NETA ATS. Guidance by test voltage. - [1 kV insulation testers for LV installations](https://amperis.com/en/products/insulation-resistance-meters/1kv/): Amperis insulation resistance testers up to 1 kV for substations and LV networks: building wiring, panels, control, telecom and PV strings; IEC 61557-2. - [Multifunction installation testers](https://amperis.com/en/products/multifunction-meters-electrical-installations/): Amperis multifunction installation testers: continuity, insulation, loop, RCD and earth in one tool; IEC 61557 and IEC 60364-6 verification. - [Tellurometers: earth resistance & resistivity](https://amperis.com/en/products/tellurometers/): Amperis tellurometers for substations and installations: earth resistance and soil resistivity by fall-of-potential and Wenner; IEC 61557-5, IEEE 81. - [Power network analysers & power quality](https://amperis.com/en/products/electric-panel-multimeters/): Amperis power network analysers for substations and buildings: power, energy, harmonics and disturbances; IEC 61000-4-30, EN 50160, IEC 62586. - [Micro-ohmmeters & loop impedance meters](https://amperis.com/en/products/ohmmeters/): Amperis micro-ohmmeters and loop impedance meters for substations: contact, joint and winding resistance; IEC 62271-1, IEC 60076-1, IEC 61557-3. - [Gas-leak imaging & specialised measurement](https://amperis.com/en/products/other-measurements/): Amperis specialised instruments for substations: optical gas-leak imaging, gas-flow and VOC detection for safety and emissions; thermography ISO 18434-1. - [Electrical Test & Measurement Equipment](https://amperis.com/en/products/): Vendor of electrical test and measurement equipment for substations: insulation, transformer, circuit-breaker, SF6, power quality and battery testing. ## Products - [Thermal Imager DL-801/2-M](https://amperis.com/en/products/cameras/infrared-camaras/thermal-imager-dl-801-2-m/): DL-801/2-M: handheld 640x480 or 1024x768 thermal camera, 0.03 °C NETD, super pixel up to 2048x1536, up to 2000 °C, GPS and laser ranging. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/thermal-imager-dl-801-2-m/DL-801-2-M_ENG.pdf - [ Amperis Battery Regenerator ](https://amperis.com/en/products/battery-maintenance-and-charging/amperis-battery-regenerator/): Amperis Battery Regenerator: MMF universal charger up to 600 V DC plus automatic discharger to remove sulphation and measure the capacity recovered. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/amperis-battery-regenerator/Brochure-Amperis-Battery-Regenerator-EN.pdf - [Acoustic Camera](https://amperis.com/en/products/cameras/corona-effect-cameras/acoustic-camera/): Acoustic camera: ultrasonic camera with 112 MEMS microphones, 2 to 100 kHz, 0.5 to 200 m, to locate partial discharge, gas leaks and abnormal noise. — datasheet: https://amperis.com/18136-Ultrasonic-V3-English.pdf - [AE736A: SF6 gas servicing cart](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-servicing-cart-ae736a/): AE736A: custom-built SF₆ servicing cart that recovers below 0.5 mbar while compressing up to 50 bar, pulls vacuum < 0.0001 mbar and filters to 0.5 µm. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-servicing-cart-ae736a/Catalogo-AMPERIS-AE736A-EN.pdf - [AGRU-4: SF6 recovery equipment](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-agru4x/): AGRU-4: recovers and liquefies SF₆ from equipment up to 69 kV with a 34 bar oil-less compressor, 2 m³/h and a 22.7 kg tank; 99.9 % with vacuum option. — datasheet: https://amperis.com/AGRU-4_ENG.pdf - [AHZAQ: dielectric PPE insulation test system](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/ahzaq/): AHZAQ: 10 kVA / 100 kV dielectric PPE test system with an 8-position bath and leakage readings up to 25.0 mA per position; ASTM D120, F496 and IEC 60903. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/ahzaq/Catalogo-AHZAQ-EN.pdf - [AK-10: three-phase relay test set](https://amperis.com/en/products/relay-testing/3-phase-relay-testing-ak-10/): AK-10: three-phase relay test set with up to 13 channels (6 current, 7 voltage), 1×120 A, Windows CE, GPS synchronisation and eight models. — datasheet: https://amperis.com/en/products/relay-testing/3-phase-relay-testing-ak-10/Brochure-AK-10-3-Phase-Relay-Testing.pdf - [AMIC-10: insulation resistance meter](https://amperis.com/en/products/insulation-resistance-meters/1kv/amic-10/): AMIC-10: pocket insulation tester at 50, 100, 250, 500 and 1000 V, up to 10 GΩ with ±(3% m.v. + 8 digits), continuity >200 mA and IP67 housing. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/1kv/amic-10/AMIC-10_eng.pdf - [AMIC-10K1: insulation tester up to 10 kV](https://amperis.com/en/products/insulation-resistance-meters/10kv/amic-10k1/): AMIC-10K1: 10 kV insulation tester up to 40 TΩ, ±(3% m.v. + 10 digits), PI, DAR, SV, DD and correction to 20/40 °C per ANSI/NETA. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/10kv/amic-10k1/Brochure-AMIC-10k1-10s1.pdf - [AMIC-15K1: insulation tester up to 15 kV](https://amperis.com/en/products/insulation-resistance-meters/15kv/amic-15k1/): AMIC-15K1: 15 kV insulation analyser up to 40 TΩ, ±(3% m.v. + 10 digits), ramp test from 100 V/min to 12 kV/min, partial discharge and SV. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/15kv/amic-15k1/Catalogo-AMIC-15K1-EN.pdf - [AMIC-2505: insulation resistance tester](https://amperis.com/en/products/insulation-resistance-meters/25kv/amic-2505/): AMIC-2505: insulation tester at 500, 1000 and 2500 V up to 2 TΩ with ±(3% m.v. + 20 digits), PI and DAR at 15/60/600 s, guard terminal, IP54. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/25kv/amic-2505/Brochure-AMIC-2505.pdf - [AMIC-5005: insulation tester up to 5 kV](https://amperis.com/en/products/insulation-resistance-meters/5kv/amic-5005/): AMIC-5005: insulation tester from 50 V to 5 kV, 50 kΩ to 15 TΩ with ±(3% m.v. + 10 digits), PI, DAR, SV and DD, 10 to 60 s digital filters. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/5kv/amic-5005/Brochure-AMIC-5005.pdf - [AMPI-520 Multifunction Electrical Installation Meter](https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi520/): AMPI-520: IEC 61557 multifunction tester with 0.13 to 1999 Ω loop at ±(5 % m.v. + 3 digits), AC, A and B RCDs from 10 to 1000 mA and insulation up to 3 GΩ. — datasheet: https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi520/Brochure-AMPI-520.pdf - [AMRU-10: earth resistance tester](https://amperis.com/en/products/tellurometers/amru-10/): AMRU-10: IP67 3-pole and 2-pole earth tester, 0.53 to 9999 Ω per EN 61557-5 with ±(3 % m.v. + 3 digits), 25 or 50 V and over 20 mA, AA cells, 660 g. — datasheet: https://amperis.com/en/products/tellurometers/amru-10/Catalogo-AMRU-10-EN.pdf - [APQM-700: power quality analyzer](https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm700/): APQM-700: class S power quality analyser (IEC 61000-4-30) for EN 50160 surveys; 760 V, 6 kA, harmonics to the 50th, IP65 from -20 to +55 °C, 6 h battery. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm700/Catalogo-APQM-700-EN.pdf - [BAC 25A-50L XXX](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/battery-charger-bac/bac-25a-50l/): BAC 25A-50L: 10 kg portable battery charger, up to 300 V DC and 25 A (BAC25A) or 60 V DC and 50 A (BAC50L), IU and UU modes for lead-acid, Ni-Cd and Li-ion. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/battery-charger-bac/bac-25a-50l/Catalogo-BAC-EN.pdf - [Battery charger Amperis MMF](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/mmf/): MMF: programmable universal battery charger, from a single cell to 600 V DC and 50 to 500 A, for formation, conditioning, testing and desulphation. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/mmf/Brochure-Charger-MMF-EN.pdf - [Battery discharge container system](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/battery-discharge-container-system/): BDCS battery discharge container system: two packs discharged at once by 2 BLU700C units of 42.0 kW each, with PLC control and thermal cameras. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/battery-discharge-container-system/Catalogo-CONTENEDOR-DESCARGA-EN.pdf - [BLU Battery Disharger](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/bluseries/): BLU-C: portable dischargers for battery capacity tests up to 800 V DC, 300 A and 42.0 kW, at constant I, P, R or U per IEEE 450 and IEC 60896. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/bluseries/Catalogo-BLU-EN.pdf - [BLU-D Series: battery charging/discharge](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/batter-charging-unit-blud/): BLU-D Series: dischargers for battery capacity tests up to 1350 V DC, 100 A and 40 kW, at constant I, P, R or U, with full discharge down to 0 V. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/batter-charging-unit-blud/Catalogo-BLU-D-EN.pdf - [CAT: circuit breaker analyzers](https://amperis.com/en/products/switch-testing/switch-testing/circuit-breaker-analyzer-cat/): CAT Standard Series: MV and HV circuit breaker analyzers with 0.1 ms resolution, 3 or 6 main contacts, ±35 A coil channels and an IP67 case of 5.5-7 kg. — datasheet: https://amperis.com/en/products/switch-testing/switch-testing/circuit-breaker-analyzer-cat/CAT-ESTANDAR_ENG.pdf - [CoroCAM 6HD](https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-6d/): CoroCAM 6HD: solar-blind UV corona camera at 2.05×10⁻¹⁸ W/cm² (3 pC at 20 m), 1920×1080 visible channel with 10x optical zoom, 1.9 kg, IP54, UAV-ready. — datasheet: https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-6d/Brochure-coroCAM-6D-EN.pdf - [CoroCAM UVS: corona inspection camera](https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-uvs/): CoroCAM UVS: 740 g UAV corona camera with solar-blind UV at 5 × 10E-18 W/cm2 (3.6 pC at 20 m), Full HD visible camera and optional thermal module. — datasheet: https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-uvs/COROCAM-UVS_ENG.pdf - [D-TEK: SF6 leak detector](https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/d-tek-sf6-leak-detector/): D-TEK: infrared SF₆ leak detector with ppm cloud hunting and pinpoint mode; sensor life up to 2,000 h, 8-10 h battery and 500 g. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/d-tek-sf6-leak-detector/DTEK-SF6-Leak-detector.pdf - [HPS Series: HV DC fast charging stations](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/hps-series-high-voltage-dc-fast-charging-stations/): HPS-HV: DC fast charging stations, 12 to 60 kW per parallelable unit, 12-650 V DC or 250-800 V DC, efficiency >97 % and CANBUS link to the BMS. — datasheet: https://amperis.com/ENG-HPS-HV-Brochure-1.pdf - [IBAR Series: battery tester](https://amperis.com/en/products/battery-maintenance-and-charging/battery-testers/ibar-battery-tester/): IBAR: battery internal resistance tester from 0 to 5 Ω with 1 µΩ resolution, voltage up to ±60 V and PASS/WARNING/FAIL verdict in about 2 s, in 0.5 kg. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-testers/ibar-battery-tester/Catalogo-IBAR-EN.pdf - [IMT-40: insulating mats testing stand](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/imt-40-stand/): IMT-40: dielectric testing stand for insulating mats up to 1200 × 1200 mm at 40 kV AC, to IEC 61111 and ASTM D1048; 120 kg without electrodes. - [IR DLD-T: temperature thermal camera](https://amperis.com/en/products/cameras/infrared-camaras/temperature-measurement-camera/): IR DLD-T: fixed 640 × 480 or 384 × 288 thermal camera for continuous monitoring, up to 10 points and 10 areas, Modbus RTU/TCP, ONVIF, POE and IP66. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/temperature-measurement-camera/DLD-T_ENG.pdf - [IR-DLD-TS: dual-spectrum thermal camera](https://amperis.com/en/products/cameras/infrared-camaras/thermal-camera-dual-spectrum/): IR-DLD-TS: dual-spectrum fixed camera, thermal up to 640 × 512 plus 1920 × 1080 visible with fusion, 30 m night vision, Modbus, ONVIF and IP66. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/thermal-camera-dual-spectrum/DLD-TS_ENG.pdf - [IRDL700 Thermographic Camera](https://amperis.com/en/products/cameras/infrared-camaras/irdl700/): IRDL700: handheld 384x288 thermal camera, 0.88 mrad and 0.06 °C or better, -20 °C to +500 °C (1200 or 2000 °C option), laser, 640x480 LCD, IP54. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/irdl700/Brochure-IRDL700-Series-EN.pdf - [Loss tangent meter in dielectric oil TAND220A](https://amperis.com/en/products/transformers-testing/tangent-meter-dielectric-oil/): TAND220A: conductivity (0.01-20,000 pS/m), permittivity and tanδ down to 10⁻⁶ meter for insulating oil to IEC 61620, with ±30 V square-wave excitation. — datasheet: https://amperis.com/en/products/transformers-testing/tangent-meter-dielectric-oil/Brochure-TAND220A-Conductivity-Meter-EN.pdf - [MSP-100: dielectric PPE tester](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-100-tester/): MSP-100: dielectric tester for gloves, boots, blankets and insulated tools up to 100 kV AC and hot sticks up to 2.5 m; ASTM D120, F496 and IEC 60903. - [MSP-100R: dielectric rods tester](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-100r-tester/): MSP-100R: hot stick tester that tests four insulating rods at once at 100 kV every 300 mm, up to 3 m; EN 60832:2010, ASTM F711 and IEEE 978. - [MSP-100S: dielectric PPE tester](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-100s-tester/): MSP-100S: dielectric tester for gloves, boots, blankets and tools up to 100 kV AC, 2.5 m hot sticks and indicators up to 110 kV; SzS-20 drying cabinet. - [MSP-100SF: PPE testing laboratory](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-100sf-testing-laboratory/): MSP-100SF: test laboratory for gloves, boots, blankets, hot sticks and indicators up to 100 kV AC, with SzS-20 dryer for 20 gloves; ASTM D120, F496, IEC 60903. - [MSP-100SFT Mobile on-site Laboratory](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-100sft-mobile-laboratory/): MSP-100SFT: trailer-mounted laboratory for on-site testing of gloves, boots, blankets, hot sticks up to 4 m and indicators; ASTM D120, F496 and IEC 60903. - [MSP-40: dielectric glove and boot tester](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-40-tester/): MSP-40: dielectric tester for class 00 to 4 gloves and class 0 to 4 sleeves and boots up to 40 kV AC, per ASTM D120, F496 and IEC 60903. - [MSP-40: high-voltage testing stand](https://amperis.com/en/products/insulation-resistance-meters/dielectric-tests/msp-40-stand/): MSP-40 high-voltage stand: dielectric testing of class 00 to 4 gloves, boots, blankets and insulated tools up to 40 kV AC; ASTM D120 and IEC 60903. - [NEXUS 1252 Powerline Analyzer](https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1252/): Nexus 1252: 0.06% revenue meter (ANSI C12.20 class 0.2) and disturbance recorder at 512 samples per cycle, with DNP 3.0 and Modbus communication. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1252/Brochure-Nexus-1252.pdf - [OT-90: oil breakdown voltage tester](https://amperis.com/en/products/transformers-testing/oil-bdv-tester-ot-90/): OT-90: oil breakdown voltage tests from 10 to 90 kV to IEC 60156, at 2 kV/s with 3 % accuracy; automatic mean and standard deviation. — datasheet: https://amperis.com/en/products/transformers-testing/oil-bdv-tester-ot-90/Catalogo-AMPERIS-OT-90-EN.pdf - [Partial discharge detector APD-ANNUNCIATOR](https://amperis.com/en/products/partial-discharge-detector/apd-annunciator/): APD-ANNUNCIATOR: continuous partial discharge monitoring of MV switchgear, 3 acoustic and 3 high-frequency channels, alarms via SCADA, web, SMS or e-mail. — datasheet: https://amperis.com/en/products/partial-discharge-detector/apd-annunciator/Brochure-APD-ANNUNCIATOR-EN.pdf - [PD Profiler: partial discharge monitor](https://amperis.com/en/products/partial-discharge-detector/pd-profiler/): PD Profiler: 8 to 20-channel partial discharge monitor with PrPD, acoustic, HF (3-80 MHz) and UHF (100-500 MHz) bands, Modbus IP and MQTT, no shutdown. — datasheet: https://amperis.com/en/products/partial-discharge-detector/pd-profiler/Catalogo-PD-Profiler-EN.pdf - [PDRM-10A Ohmmeter](https://amperis.com/en/products/ohmmeters/pdrm-10a/): PDRM-10A: four-wire Kelvin micro-ohmmeter from 0.01 µΩ to 200 Ω with ±0.1% ±2 digits, automatic 5 mA, 250 mA or 10 A DC test current and 0.86 kg. — datasheet: https://amperis.com/en/products/ohmmeters/pdrm-10a/Catalogo-AMPERIS-PDRM-10A-EN.pdf - [Powerline Analyzer SHARK 100](https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-100/): Shark 100 panel power meter: class 0.2 ANSI C12.20 / 0.2S IEC 62053-22, over 400 samples per cycle, DNP3 and THD via V-Switch keys. Request a quote. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-100/Brochure-Shark-100.pdf - [Rapidox 1100Z: oxygen analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/rapidox-sf6/): Rapidox 1100Z: zirconia oxygen analyser from 1 ppm to 30 % O₂, ±1 % of the actual concentration, 90 % response in 4 s and a 0-1.2 L/min pump. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/rapidox-sf6/Rapidox-1100Z-English.pdf - [Reliable hot and dusty gas flow measurement](https://amperis.com/en/products/other-measurements/reliable-gas-flow-measurement/): McON Air: correlation flow measurement for hot, dusty gases up to 1000 °C and 2500 g/m³, ±2% accuracy, 25:1 turn-down, no drift, calibration or purging. — datasheet: https://amperis.com/en/products/other-measurements/reliable-gas-flow-measurement/Catalogo-AMPERIS-MCON-AIR-EN.pdf - [RMO-G Series: contact micro-ohmmeters](https://amperis.com/en/products/switch-testing/microhmmeters/rmo-g/): RMO-G: 100 to 800 A DC micro-ohmmeters with Both Sides Grounded (BSG) testing, ±(0.1 % + 0.1 %) typical accuracy, 0.1 µΩ to 6 Ω and IP67 case. — datasheet: https://amperis.com/en/products/switch-testing/microhmmeters/rmo-g/Catalogo-RMO-G-EN.pdf - [SAT40A II Series: coil analyzers](https://amperis.com/en/products/switch-testing/coil-testing/coil-analyzers/): SAT40A II: power source for breaker coils (10-300 V DC, up to 15 A) and motors (40 A) that measures coil resistance and minimum trip voltage. — datasheet: https://amperis.com/en/products/switch-testing/coil-testing/coil-analyzers/Catalogo-SAT40A-EN.pdf - [SF Series Infrared Module: SF641, SF643 and SF740](https://amperis.com/en/products/cameras/infrared-camaras/mini-infrared-mod/): SF series infrared modules SF641, SF643 and SF740: VOx 640×512, athermalised lenses, analogue, LVCMOS and MIPI outputs, 120 Hz option, 5 V DC. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/mini-infrared-mod/SF-SERIES_ENG.pdf - [TC706: SF₆ leak location on GIS and circuit breakers](https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/gas-detection-tc706/): TC706: locates SF₆ leaks on live GIS, switchgear and circuit breakers from a distance, with no outage; cooled 320 × 256 QWIP detector, 3 kg, IP54. — datasheet: https://amperis.com/TC706_ENG.pdf - [TC721: gas leak detection thermal imager](https://amperis.com/en/products/other-measurements/gas-leak-thermal-camera-tc721/): TC721: cooled 320 × 256 OGI camera at 3.2-3.5 µm that shows CH₄ and VOC leaks from up to 80 m; NETD ≤ 0.015 °C and Ex ic hazardous-area rating. — datasheet: https://amperis.com/TC721_ENG.pdf - [TRT Standard Series: turns ratio meter](https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/standar-series/): TRT Standard Series (TRT03, TRT33, TRT63): turns ratio tester 0.8–50,000 up to 250 V AC, ±0.03% typical accuracy and on-load tap changer control. — datasheet: https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/standar-series/Catalogo-TRT-ESTANDAR-EN.pdf - [TWA Standard Series: winding resistance](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/twa-standar-series/): TWA Standard Series: winding resistance of all six windings in one connection, 0.1 µΩ–10 kΩ, ±(0.1% rdg + 0.1% FS), up to 40 A DC, DVtest and demagnetization. — datasheet: https://amperis.com/en/products/transformers-testing/winding-ohmmeters/twa-standar-series/Catalogo-TWA-ESTANDAR-EN.pdf - [TWR-H: turns ratio and winding resistance](https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/winding-resistance-tester/): TWR-H: handheld turns ratio (0.8–20 000, ±0.1%) and winding resistance (1 µΩ–3 kΩ) tester with demagnetization, battery-powered and only 1.4 kg. — datasheet: https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/winding-resistance-tester/Catalogo-TWR-H-EN.pdf - [VIPO-85: vacuum interrupter tester 85 kV](https://amperis.com/en/products/switch-testing/vipo-85/): VIPO-85: vacuum interrupter tester and DC hipot up to 85 kV in 1 kV steps, PASS/FAIL at 100, 200 or 300 µA per ANSI/IEEE, printer and IP67 case. — datasheet: https://amperis.com/VIPO-85_ENG.pdf - [VOC gas thermal imager](https://amperis.com/en/products/other-measurements/voc-gas-thermal-imager/): VOC-300: gas imaging camera with a cooled 320 × 256 MCT detector at 3.2-3.4 µm and NETD ≤ 10 mK to see VOC leaks; measures −20 to 410 °C, 3.2 kg. — datasheet: https://amperis.com/voc-gas-thermal-imager.pdf - [XD Series: battery discharger and cycler](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/cycler-batteries-xd/): XD battery discharger and analyzer: constant-current capacity tests up to 20 kW and 200 A on lead-acid, lithium and sodium-ion batteries. — datasheet: https://amperis.com/ENG-Descargador-Analizador-Ciclador-Baterias-Universal-Serie-XD-en.pdf - [XMV Series: multi-voltage battery charger](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/multi-voltage-battery-charger/): XMV: programmable multi-voltage charger, 2-150 V DC (2-180 V DC E range), 3 to 40 kW and up to 600 A, for lead-acid and lithium batteries, PF >0.98. — datasheet: https://amperis.com/XMV-ENG.pdf - [AHZJQ-X1: transformer oil breakdown voltage tester](https://amperis.com/en/products/transformers-testing/ahzjq-x1/): AHZJQ-X1 automatic insulating oil BDV tester up to 80 kV: IEC 60156 and custom sequences, 0.5-5 kV/s, touch screen, printer, USB, 100 results. — datasheet: https://amperis.com/en/products/transformers-testing/ahzjq-x1/AHZJQ-X1_ENG.pdf - [AK-30: three-phase relay test set](https://amperis.com/en/products/relay-testing/3-phase-relay-testing-ak-30/): AK-30 and AK-31: 10- and 13-channel relay test sets, up to 6×32 A and 1×100 A, 0.07 % accuracy and GPS; the AK-31 adds IEC 61850 fibre ports. — datasheet: https://amperis.com/en/products/relay-testing/3-phase-relay-testing-ak-30/Brochure-AK30-AK31-Three-Phase-Relay-Test-Set.pdf - [AMIC-30: megohmmeter insulation tester](https://amperis.com/en/products/insulation-resistance-meters/1kv/amic-30/): AMIC-30: megohmmeter from 50 to 1000 V in 10 V steps, up to 100 GΩ with ±(3% m.v. + 8 digits), DAR and PI, continuity >200 mA and IP67. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/1kv/amic-30/Brochure-AMIC-30.pdf - [AMIC-5010: insulation resistance tester](https://amperis.com/en/products/insulation-resistance-meters/5kv/amic-5010/): AMIC-5010: 5 kV insulation tester, 50 kΩ to 15 TΩ with ±(3% m.v. + 10 digits), PI, DAR, SV and DD, 200 mA continuity, works next to live HV. — datasheet: https://amperis.com/en/products/insulation-resistance-meters/5kv/amic-5010/Brochure-AMIC-5010.pdf - [AMPERIS ACBX Battery Simulator](https://amperis.com/en/products/battery-maintenance-and-charging/acbx/): ACBX battery simulator for testing 12 to 80 V chargers up to 200 A without a battery, with the real charging curve in 1 minute; it also discharges batteries. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/acbx/Brochre-ACBX-Battery-Simulator-Amperis-EN.pdf - [Amperis Battery Discharger BDC](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/battery-discharger-amperis/): Amperis Battery Discharger BDC: constant-current capacity testing from 48 to 600 V and up to 200 A, with automatic stop and the full curve recorded. — datasheet: https://amperis.com/BDC_ENG.pdf - [AMPI-525: multifunction installation tester](https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi525/): AMPI-525: multifunction tester with 50 to 2500 V insulation testing up to 9.99 GΩ per IEC 61557-2, 0.13 to 1999 Ω loop, AC, A and B RCDs and 3-pole earth. — datasheet: https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi525/Brochure-AMPI-525.pdf - [APQM-702/703: power quality analyzers](https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm702-703/): APQM-702/703: class A power quality analysers (IEC 61000-4-30) with GPS and GSM, ±0.1% Unom up to 1000 V; the APQM-703 records ±8000 V transients. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm702-703/datasheet_PQM-702_703_EN_v4.00.pdf - [Battery Charger / Rectifier MMF-ASR](https://amperis.com/en/products/battery-maintenance-and-charging/battery-chargers-and-rectifiers/mmf-asr/): MMF-ASR: IGBT battery charger/rectifier from 24 to 220/240 V DC and 10 to 500 A for lead-acid, VRLA and Ni-Cd batteries and critical DC loads. - [Battery Tester CA 6630](https://amperis.com/en/products/battery-maintenance-and-charging/battery-testers/battery-tester-ca6630/): CA 6630: 4-wire battery tester from 40 mΩ to 40 Ω (resolution from 10 µΩ) plus open-circuit voltage up to 40 V, with comparator and 999-reading memory. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-testers/battery-tester-ca6630/Brochure-CA-6630-EN.pdf - [CAT Advanced Series: breaker analyzers](https://amperis.com/en/products/switch-testing/switch-testing/advanced/): CAT Advanced Series: HV circuit breaker analyzers with 12 contacts, 6 coils, 40 kHz sampling and a 200 or 500 A micro-ohmmeter for dynamic resistance. — datasheet: https://amperis.com/en/products/switch-testing/switch-testing/advanced/Catalogo-CAT-AVANZADA-EN.pdf - [CoroCAM 7HD](https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-7/): CoroCAM 7HD: solar-blind corona camera with sensitivity certified to IEC 60270:2000 at 1.0 pC at 15 m, 30x optical zoom, IP55 and 2.2 kg. — datasheet: https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-7/Brochure-CoroCAM-7HD-English.pdf - [Dielectric strength meter Dielectrotest](https://amperis.com/en/products/transformers-testing/dielectrotest/): Dielectrotest: automatic oil breakdown voltage tester up to 100 kV, ±1 kV accuracy, 0.1-10 kV/s voltage rise and switch-off in less than 1 ms. — datasheet: https://amperis.com/en/products/transformers-testing/dielectrotest/Brochure-Dielectrotest-English.pdf - [Dynamic Ratings B100 Electronic Temperature Monitor (ETM)](https://amperis.com/en/products/transformers-testing/b100/): B100: transformer temperature monitor that replaces up to 5 gauges, calculates the hot spot of 3 windings and adds optional H₂ and moisture-in-oil sensing. — datasheet: https://amperis.com/B100_ENG.pdf - [Dynamic Ratings C50 Bushing Monitor](https://amperis.com/en/products/transformers-testing/c50/): C50: transformer bushing monitor (online capacitance and power factor) that also monitors the OLTC, cooling, third-party DGA and voltage control. — datasheet: https://amperis.com/C50_ENG.pdf - [Dynamic Ratings E3 Transformer Monitor](https://amperis.com/en/products/transformers-testing/e3/): E3: modular power transformer monitor covering bushings, OLTC, DGA, fibre optics, dynamic rating and cooling and voltage control; up to 12 modules. — datasheet: https://amperis.com/E3_ENG.pdf - [Dynamic Ratings RMM Rotating Machine Monitor](https://amperis.com/en/products/partial-discharge-detector/rmm/): RMM: continuous partial discharge monitor for MV and HV motors and generators; 15 channels per module, 70 dB (3 mV-10 V), 1-20 MHz and 2 years of data. — datasheet: https://amperis.com/RMM_ENG.pdf - [ET91 2.4 MHz selective level meter](https://amperis.com/en/products/other-measurements/selective-level-meter-et91/): ET91: selective level meter, generator, bridge and spectrum analyzer from 100 Hz to 2400 kHz for PLC and FDM; ±0.3 dB, -120 to +10 dB, 8 h battery. — datasheet: https://amperis.com/ET91_ENG.pdf - [GRIDSCAN5000 hydrogen sensor](https://amperis.com/en/products/transformers-testing/hydrogen-sensor-gridscan5000/): GRIDSCAN5000: solid-state hydrogen sensor for transformers, 25-5,000 ppm in oil, ±20 % or ±25 ppm, self-calibrating, Modbus and DNP3. — datasheet: https://amperis.com/GRIDSCAN5000_ENG.pdf - [Hydrogen Area Monitor](https://amperis.com/en/products/battery-maintenance-and-charging/hydrogen-area-monitor/): HY-GUARD hydrogen monitor for battery rooms: hydrogen-specific solid-state sensor, 0.4-5 %, ±0.3 %, 1 % and 2 % relays, Modbus and 4-20 mA. — datasheet: https://amperis.com/MONITOR-H2_ENG.pdf - [Insulating Oil Dielectric Loss & Resistivity Tester](https://amperis.com/en/products/transformers-testing/hzjd-2z/): HZJD-2Z: measures tanδ from 0.00001 to 100 (±1 % + 0.0001), relative permittivity and DC resistivity up to 20 TΩ·m of insulating oils to IEC 60247. — datasheet: https://amperis.com/en/products/transformers-testing/hzjd-2z/Catalogo-HZJD-2Z-EN.pdf - [IRDL708 Series: thermal imaging cameras](https://amperis.com/en/products/cameras/infrared-camaras/irdl708-series/): IRDL708 Series: portable 640 × 480 thermal camera, NETD ≤ 0.02 °C, 0.65 mrad, −40 °C to +650 °C (2000 °C option), 5 MP visible fusion and IP54. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/irdl708-series/Brochure-IRDL708-Series.pdf - [Ohmmeter PDRM-1A](https://amperis.com/en/products/ohmmeters/pdrm-1a/): PDRM-1A: four-point Kelvin micro-ohmmeter from 1 µΩ to 200 Ω, 0.1% of reading ±2 counts accuracy, automatic test current up to 1 A DC and 0.86 kg. — datasheet: https://amperis.com/en/products/ohmmeters/pdrm-1a/PDRM-1A_EN.pdf - [PADD Lightning Rod Flaw Detector](https://amperis.com/en/products/partial-discharge-detector/add/): PADD: contact detector of defective arresters on energised overhead lines up to 69 kV, with 6 levels in 2 zones, audible alert and Auto-Test. — datasheet: https://amperis.com/en/products/partial-discharge-detector/add/Brochure-PADD.pdf - [Powerline analyser SHARK 100-S](https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-100-s/): Shark 100-S: 0.2 % class ANSI C12.20 energy submeter with IEEE 802.11b WiFi, RJ45 Ethernet and Modbus TCP, RS485, KYZ pulse and THD with the V4 key. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-100-s/Brochure-Shark-100-S.pdf - [Powerline Analyzer NEXUS 1272](https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1272/): Nexus 1272: 0.06% revenue meter (IEC 62053-22 class 0.2S, ANSI C12.20 class 0.2) with waveform recording at up to 512 samples per cycle. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1272/Brochure-1272-EN.pdf - [Rapidox 2100: oxygen analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/oxygen-analyzer-rapidox-2100/): Rapidox 2100: oxygen analyser with a remote zirconia sensor up to 25 m away and gas up to 650 °C; 10E-20 ppm to 30 % O₂, ±1 % or 0.5 ppm, 90 % in 4 s. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/oxygen-analyzer-rapidox-2100/Rapidox-2100-English.pdf - [RMO-A: circuit-breaker micro-ohmmeter](https://amperis.com/en/products/switch-testing/microhmmeters/rmo-a/): RMO-A: 100 to 600 A DC micro-ohmmeter for circuit breaker contact resistance, 0.1 µΩ to 6 Ω, ±(0.1 % + 0.1 %) typical accuracy, 7-8 kg. — datasheet: https://amperis.com/en/products/switch-testing/microhmmeters/rmo-a/Catalogo-RMO-A-EN.pdf - [SF6 leak detector](https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/sf6-leak-detector/): D-TEK Stratus: infrared SF₆ leak detector with ppm cloud hunting and pinpointing; EN 14624:2020, sensor life up to 2,000 h and 8-10 h battery. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-leak-detectors/sf6-leak-detector/SF6-GAS-LEAK-DETECTOR_EN.pdf - [SF6 recovery system AGRU-8 series](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-recovery-system-agru-8/): AGRU-8: recovers SF₆ from equipment up to 256 kV at 51 kg/h with a 69 bar oil-less compressor; < 1 mbar residual and 160 kg on board (300 kg with tank). — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-recovery-system-agru-8/AGRU-8_eng.pdf - [Telurometer AMRU 120](https://amperis.com/en/products/tellurometers/amru-120/): AMRU-120: 3- and 4-wire, clamp and double-clamp earth tester, 0.30 Ω to 19.9 kΩ per IEC 61557-5 with over 200 mA, Wenner soil resistivity and continuity. — datasheet: https://amperis.com/en/products/tellurometers/amru-120/AMRU-120_eng.pdf - [TRT Advanced Series: turns ratio meter](https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/advanced-series/): TRT Advanced Series (TRT100 to TRT500): turns ratio tester up to 500 V AC, ±0.03% typical accuracy, touch screen and 32 GB of memory. — datasheet: https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/advanced-series/Catalogo-TRT-AVANZADA-EN.pdf - [TWA Advanced Series: winding resistance](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/twa-advanced-series/): TWA Advanced Series: six windings from 0.1 µΩ to 10 kΩ at ±(0.1% rdg + 0.1% FS), up to 40 A DC, three-phase DVtest at 0.1 ms, vibration and automatic test. — datasheet: https://amperis.com/en/products/transformers-testing/winding-ohmmeters/twa-advanced-series/Catalogo-TWA-AVANZADA-EN.pdf - [TWR250B turns ratio and winding resistance analyzer](https://amperis.com/en/products/transformers-testing/transformer-ratio-meters/turns-ratio-winding-resistance-analyzer-twr250b/): TWR250B: true three-phase turns ratio analyzer (±0.03 %) and winding resistance tester up to 25 A DC, with demagnetization and OLTC control. — datasheet: https://amperis.com/TWR250B_ENG.pdf - [AK-6: three-phase relay test set](https://amperis.com/en/products/relay-testing/equipo-prueba-reles-trifasicos-ak-6/): AK-6: all-in-one three-phase relay test set with Windows CE; 3×35 A, 1×105 A and 4×300 V, 0.07 % accuracy and five test modules without a PC. — datasheet: https://amperis.com/en/products/relay-testing/equipo-prueba-reles-trifasicos-ak-6/Brochure-AK-68-3-Phase-Relay-Testing.pdf - [AMPI-530: multifunction installation tester](https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi530/): AMPI-530: IEC 61557 multifunction tester, 0.13 to 1999.9 Ω loop (0.001 Ω res.), AC, A and B RCDs, insulation up to 9.99 GΩ, clamp earth testing and recorder. — datasheet: https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi530/Brochure-AMPI-530.pdf - [AMZC-304: loop impedance meter](https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc304/): AMZC-304: loop impedance meter from 0.13 to 1999 Ω per EN 61557 with 0.01 Ω resolution, no-trip RCD mode, Bluetooth and an IP67 housing. — datasheet: https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc304/AMZC-304_eng.pdf - [APD-LT Partial Discharge Meter](https://amperis.com/en/products/partial-discharge-detector/apd-lt/): APD-LT: hotstick partial discharge meter for overhead lines, contactless capacitive sensor, 60 dB, ± 2 dB, 30-47 MHz and a BLE remote display at 30 m. — datasheet: https://amperis.com/en/products/partial-discharge-detector/apd-lt/Brochure-APD-LT-EN.pdf - [APQM-707 wave quality analyzer](https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm707/): APQM-707: portable class S power quality analyser (IEC 61000-4-30) with a 7-inch touchscreen, 760 V, 6 kA, harmonics to the 50th and EN 50160 reports. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm707/Catalogo-APQM-707-EN.pdf - [BVS Series: battery monitoring system](https://amperis.com/en/products/battery-maintenance-and-charging/bvs/): BVS: cell-by-cell monitoring in capacity tests, cell voltage ±30 V (1 mV, ±0.1 %), inter-cell ±50 mV (1 µV) and string ±600 V, with LED alerts on each module. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/bvs/Catalogo-BVS-EN.pdf - [CA Resistance Bank](https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/ca-resistance-bank/): Amperis AC load bank for testing UPS and AC power supplies: power factor from 0.8 to 1.0, 5 to 120 kW per element and local or remote control. — datasheet: https://amperis.com/en/products/battery-maintenance-and-charging/battery-dischargers/ca-resistance-bank/Brochure-AC-Load-Bank.pdf - [CAB: handheld breaker and timer analyser](https://amperis.com/en/products/switch-testing/switch-testing/handheld-circuit-breaker-analyzer-cab/): CAB (CAT-P and CAT-H): 1.4-1.6 kg handheld circuit breaker analyzer; timing with 0.05 ms resolution and 0.05% accuracy, ±35 A coils, 8 h battery. — datasheet: https://amperis.com/en/products/switch-testing/switch-testing/handheld-circuit-breaker-analyzer-cab/CAB_ENG.pdf - [CoroCAM 8HD](https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-8/): CoroCAM 8HD: solar-blind UV corona camera (3 pC at 20 m) plus 640×512 radiometric thermal camera from -40 to 160 °C, with 30x optical zoom in the visible. — datasheet: https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-8/Brochure-coroCAM-8-EN.pdf - [Distribution transformer tester ADOC-3](https://amperis.com/en/products/transformers-testing/distribution-transformer-tester-adoc-3/): ADOC-3: go/no-go tester that detects short-circuits and open circuits in distribution transformers from 1 kVA to 3 MVA in about 60 s. — datasheet: https://amperis.com/en/products/transformers-testing/distribution-transformer-tester-adoc-3/Brochure-ADOC-3-Tester-English.pdf - [Nexus 1450 Power Quality Meter](https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1450/): Nexus 1450: class A power quality meter (IEC 61000-4-30) and 0.06 % class 0.2S revenue meter, with a transducer base that replaces the 125x series. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1450/Brochure-Nexus-1450-EN.pdf - [Powerline Analyzer SHARK 200](https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-200/): Shark 200 class 0.2S panel meter: 4 MB data logging, harmonics up to the 40th, waveform capture and Ethernet with Modbus TCP, DNP3 or IEC 61850. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-shark/shark-200/Brochure-Shark-200.pdf - [Rapidox 2100-FGA: gas analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/forming-gas-analyser-rapidox-2100-fga/): Rapidox 2100-FGA: forming gas analyser measuring O₂ from 10E-30 ppm to 30 % with ±1 % or 0.5 ppm, calculating the H₂O dewpoint, response under 4 s. — datasheet: https://amperis.com/RAPIDOX-2100-FGA_ENG.pdf - [RMO-H: lightest micro-ohmmeter](https://amperis.com/en/products/switch-testing/microhmmeters/rmo-h/): RMO-H: 0.95 kg handheld micro-ohmmeter with 1 to 300 A DC regulated from a Li-Po battery, 0.1 µΩ to 3000 mΩ, ±(0.1 % + 0.1 %) typical, Bluetooth. — datasheet: https://amperis.com/en/products/switch-testing/microhmmeters/rmo-h/Catalogo-RMO-H-EN.pdf - [RMO-TT Series: winding resistance meter](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rom-tt-series/): RMO-TT: winding resistance up to 100 A DC, ±(0.1% rdg + 0.1% FS), 0.1 ms tap changer DVtest, vibration with a ±50 g accelerometer and four Pt100 channels. — datasheet: https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rom-tt-series/Catalogo-RMO-TT-EN.pdf - [SF6 gas transfer unit AGTU](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-transfer-unit-agtu/): AGTU: recovers, consolidates and transfers SF₆ up to 69 kV with a 34 bar oil-less compressor, 2 m³/h and 0.1 µm filtration in a 34 kg steel unit. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-transfer-unit-agtu/AGTU_eng.pdf - [TC4/TC8 Series: thermal cameras](https://amperis.com/en/products/cameras/infrared-camaras/predictive-maintenance-infrared-cameras-tc4-8-series/): TC4/TC8: handheld 160 × 120 or 384 × 288 thermal cameras, NETD ≤ 0.06 °C, up to 2000 °C (TC8), 3 MP fusion, 2 m drop resistant, IP54, 0.98 kg. — datasheet: https://amperis.com/en/products/cameras/infrared-camaras/predictive-maintenance-infrared-cameras-tc4-8-series/Brochure-TC4-TC8-Series-EN.pdf - [Telurometer AMRU-200](https://amperis.com/en/products/tellurometers/amru-200/): AMRU-200: 2-, 3- and 4-wire, clamp, double-clamp and impulse (0-200 Ω) earth tester, 0.10 Ω to 19.9 kΩ per IEC 61557-5 with 0.001 Ω resolution. — datasheet: https://amperis.com/en/products/tellurometers/amru-200/AMRU-200_eng.pdf - [AE865C: mini oil degasifier](https://amperis.com/en/products/transformers-testing/mini-degasifier-ae865c/): AE865C: portable mini degasifier that leaves oil with under 10 ppm of water and 0.25 % of gas at 230 l/h, with a vacuum below 0.025 mbar. — datasheet: https://amperis.com/en/products/transformers-testing/mini-degasifier-ae865c/Brochure-Mini-Oil-Degasifier-AE865C-EN.pdf - [AHZJB-1200: 6-phase relay protection test set](https://amperis.com/en/products/relay-testing/6-phase-relay-test-set-ahzjb-1200/): AHZJB-1200: relay protection test set with 6 voltages and six 30 A currents (180 A in parallel), class 0.2, built-in computer and display. — datasheet: https://amperis.com/en/products/relay-testing/6-phase-relay-test-set-ahzjb-1200/AHZJB-1200_ENG.pdf - [AMPI-530-IT: multifunction IT tester](https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi530-it/): AMPI-530-IT: IEC 61557 multifunction meter for TN, TT and IT networks; RCDs from 10 to 1000 mA, loop from 0.13 Ω, insulation at 1000 V, IP54. — datasheet: https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi530-it/Catalogo-MPI-530-IT-EN.pdf - [AMZC-305: loop impedance meter](https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc305/): AMZC-305: loop impedance from 0.13 to 1999 Ω (IEC 61557) in 110/190 to 400/690 V networks, up to 750 V phase to phase, no-trip RCD mode and USB. — datasheet: https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc305/AMZC-305_eng.pdf - [APQM-711 wave quality analyzer](https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm710-711/): APQM-711: class A power quality analyser (IEC 61000-4-30) with ±8000 V transients at 10 MHz, GPS, Wi-Fi and a 4G LTE modem for remote operation. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-apqm/apqm710-711/Catalogo-APQM-711-EN.pdf - [CoroCAM 8 UAV: corona inspection camera](https://amperis.com/en/products/cameras/corona-effect-cameras/corocam-8uav/): CoroCAM 8UAV: drone corona camera with solar-blind UV at 2.05 × 10E-18 W/cm2, 640 × 512 LWIR < 50 mK and 28× zoom visible camera, in 1.6 kg. — datasheet: https://amperis.com/COROCAM-8UAV_ENG.pdf - [Dynamic Ratings BPM Breaker Performance Monitor](https://amperis.com/en/products/switch-testing/switch-testing/bpm/): BPM: online HV circuit breaker monitor with Smart Capture on every operation, cumulative I²T, trip coil and SF₆ gas monitoring; DNP3, Modbus and IEC 61850. — datasheet: https://amperis.com/BPM_ENG.pdf - [Nexus 1500 wave quality analyzer](https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1500/): Nexus 1500+: class A analyser (IEC 61000-4-30) and 0.06 % class 0.2S revenue meter with 50 MHz transients, harmonics to the 511th and synchrophasors. — datasheet: https://amperis.com/en/products/electric-panel-multimeters/serie-nexus/nexus-1500/Brochure-Nexus-1500.pdf - [Partial discharge detector PXDP-II](https://amperis.com/en/products/partial-discharge-detector/pxdp2/): PXDP-II: portable partial discharge detector with 5 pC sensitivity, 60 dB, 300 kHz-70 MHz, TEV, HFCT and acoustic sensors and 7.5 h of autonomy. — datasheet: https://amperis.com/en/products/partial-discharge-detector/pxdp2/Catalogo-PXDP-II-EN.pdf - [Rapidox 3100Z: multigas analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-3100z/): Rapidox 3100Z: multigas analyser for up to 3 simultaneous gases, zirconia O₂ from 10E-20 ppm to 30 % at ±1 %, type K input to 1250 °C and 4 alarms. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-3100z/Rapidox-3100-EN.pdf - [RMO-TD Series: winding resistance meter](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rmo-td-series/): RMO-TD: winding resistance up to 60 A DC and 55 V, ±(0.1% rdg + 0.1% FS), 0.1 ms DVtest of the on-load tap changer, OLTC control and demagnetization. — datasheet: https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rmo-td-series/Catalogo-RMO-TD-EN.pdf - [SF6 gas recovery unit AGRU-7](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-recovery-unit-agru7/): AGRU-7: recovers SF₆ from breakers up to 132 kV with a 2 m³/h, 34 bar oil-less compressor; 104 kg on board and 99.9 % (< 1 mbar) in the XDS version. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/sf6-gas-recovery-unit-agru7/AGRU-7_ENG.pdf - [Switch Analyser SA10](https://amperis.com/en/products/switch-testing/switch-testing/sa10/): SA10A: circuit breaker analyser with 12 main and 6 auxiliary channels, travel and a 200 A micro-ohmmeter (0-1000 µΩ, ±2 µΩ) in a 12 kg case. — datasheet: https://amperis.com/en/products/switch-testing/switch-testing/sa10/Brochure-SA10-Switch-Analyzer.pdf - [TC706: SF6 gas-detection camera](https://amperis.com/en/products/cameras/infrared-camaras/gas-detection-tc706/): TC706: OGI camera with a cooled 320 × 256 QWIP detector at 9.8-11.2 µm that shows SF₆ as a live plume; NETD ≤ 0.025 °C, 60 Hz frame rate. — datasheet: https://amperis.com/TC706_ENG.pdf - [Telurometer AMRU-200 GPS](https://amperis.com/en/products/tellurometers/amru-200-gps/): AMRU-200 GPS: earth tester with GPS (3 m CEP), 2-, 3- and 4-pole earth resistance from 0.10 Ω, 4/10, 8/20 and 10/350 μs pulse, double clamp and Wenner. — datasheet: https://amperis.com/en/products/tellurometers/amru-200-gps/Telurometer-AMRU-200-GPS-EN.pdf - [AEHV: vacuum oil purifier](https://amperis.com/en/products/transformers-testing/vacuum-oil-purifiers-aehv/): AEHV: vacuum oil purifier taking water from 50 to under 5 ppm and air from 12 % to 0.25 % in one pass; nine models from 200 to 12 000 l/h. — datasheet: https://amperis.com/en/products/transformers-testing/vacuum-oil-purifiers-aehv/Brochure-Vacuum-Oil-Purifiers-AEHV-EN.pdf - [AHZJB-I: three-phase relay protection test set](https://amperis.com/en/products/relay-testing/3-phase-relay-test-set-ahzjb-i/): AHZJB-I: three-phase relay protection test set with 4 voltages and three 40 A currents (120 A in parallel), stand-alone or PC operation; 22 kg. — datasheet: https://amperis.com/en/products/relay-testing/3-phase-relay-test-set-ahzjb-i/AHZJB-I_ENG.pdf - [AMPI-540: multifunction installation meter](https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi540/): AMPI-540: IEC 61557 multifunction meter with a three-phase class S power quality recorder (EN 61000-4-30), 7" touchscreen and Li-Ion battery. — datasheet: https://amperis.com/en/products/multifunction-meters-electrical-installations/mpi540/Catalogo-AMPI-540-EN.pdf - [AMZC-306: loop impedance meter](https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc-306/): AMZC-306: loop impedance from 0.13 to 1999 Ω (IEC 61557) in 110/190 to 400/690 V networks, short-circuit current up to 69.0 kA and no-trip RCD mode. — datasheet: https://amperis.com/en/products/ohmmeters/loop-impedance-meter-amzc-306/AMZC-306_eng.pdf - [Gas Filling Regulation Unit ARFU-2 SF6](https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/gas-filling-regulation-sf6-arfu2/): ARFU-2: 31 kg cart that evacuates switchgear and breakers with a 17 m³/h pump (< 0.03 mbar) and regulates SF₆ filling from standard cylinders. — datasheet: https://amperis.com/en/products/switch-testing/sf6/sf6-gas-servicing-equipment/gas-filling-regulation-sf6-arfu2/ARFU-2_eng.pdf - [Rapidox 5100: multigas analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-5100/): Rapidox 5100: portable multigas analyser for up to 6 gases (CH₄, CO₂, O₂, H₂S…) with calorific value, 2-4 min measurement, IP66 case and 8 h+ battery. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-5100/Brochure-Rapidox-5100-MultiGas-EN.pdf - [RMO-TW Series: winding resistance meter](https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rmo-tw-series/): RMO-TW: 10 to 50 A DC winding ohmmeter at 55 V weighing 8 kg, three channels, ±(0.1% rdg + 0.1% FS), tap changer verification and demagnetization. — datasheet: https://amperis.com/en/products/transformers-testing/winding-ohmmeters/rmo-tw-series/Catalogo-RMO-TW-EN.pdf - [Ultrasonic inspection system PULD 40](https://amperis.com/en/products/partial-discharge-detector/puld-40/): PULD-40: 40 kHz ultrasonic detector (38-48 kHz, 96 dB) for corona, arcing and leaks, with laser-sighted parabolic sensor for 15 m, 528 g and 4 h battery. — datasheet: https://amperis.com/en/products/partial-discharge-detector/puld-40/Brochure-PULD-40.pdf - [High Current Short Circuit Loop Impedance Meter AMZC-310S](https://amperis.com/en/products/ohmmeters/amzc-310s/): AMZC-310S: high-current loop meter (up to 280 A, four-wire) from 7.2 to 1999 mΩ with 0.1 mΩ resolution, short-circuit current and touch voltage. — datasheet: https://amperis.com/en/products/ohmmeters/amzc-310s/AMZC-310S_eng.pdf - [Rapidox 6100: portable gas analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/portable-gas-analyser-rapidox-6100/): Rapidox 6100 Portable: 8.5 kg SF₆ analyser measuring purity (±0.5 %), dew point, SO₂, HF, H₂S and CO at once, with IEC and CIGRE test presets. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/portable-gas-analyser-rapidox-6100/Brochure-Rapidox-6100-Portable-Gas-EN.pdf - [Rapidox 6100 Pump Back: SF6 analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/pump-back-gas-analyser/): Rapidox 6100 Pump Back: automatic SF₆ analyser that returns the gas with a 10 bar compressor; inlet up to 35 bar, ±0.5 % purity and up to 8 gases. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/pump-back-gas-analyser/Brochure-Rapidox-6100-Pump-Back-Gas-EN.pdf - [Rapidox 7100: multigas analyser](https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-7100/): Rapidox 7100: 19-inch rack or benchtop multigas analyser, up to 7 gases, calorific value, 0-10 V, 4-20 mA and Modbus RTU/Ethernet outputs. — datasheet: https://amperis.com/en/products/switch-testing/sf6/gas-analysers/multigas-analyser-rapidox-7100/Brochure-Rapidox-7100-MultiGas-EN.pdf ## Resources - [Insulation resistance calculator: temperature correction, PI and DAR](https://amperis.com/en/resources/tools/insulation-resistance-calculator/) - [Transformer winding resistance calculator: correction to 75 °C and phase imbalance](https://amperis.com/en/resources/tools/winding-resistance-calculator/) - [Stationary battery calculator: sizing, autonomy and capacity test](https://amperis.com/en/resources/tools/battery-sizing-calculator/) - [Dissolved gas analysis calculator: Duval triangles and pentagons, IEC 60599:2022 and IEEE](https://amperis.com/en/resources/tools/dga-calculator-duval-triangle/) - [Moisture in transformer oil calculator: ppm, relative saturation, IEC 60422:2024 and IEEE C57.106-2015](https://amperis.com/en/resources/tools/moisture-in-transformer-oil-calculator/) - [SF6 calculator: mass, moisture, leaks, recovery and gas quality](https://amperis.com/en/resources/tools/sf6-gas-mass-and-moisture-calculator/) - [Bushing tan δ and capacitance calculator](https://amperis.com/en/resources/tools/bushing-tan-delta-calculator/) - [Earthing calculator: soil resistivity, grid, step and touch voltage](https://amperis.com/en/resources/tools/earthing-resistance-calculator/) - [Transformer loading calculator per IEEE C57.91-1995: hot spot, overload, and loss of life](https://amperis.com/en/resources/tools/transformer-loading-hot-spot-calculator/) - [Power quality calculator: THD, K-factor, unbalance and reactive power](https://amperis.com/en/resources/tools/power-quality-calculator/) - [Cable size calculator: mm² and AWG, protection, short circuit and medium voltage](https://amperis.com/en/resources/tools/cable-size-calculator/) - [Physical unit converter: 111 quantities and nearly 1,200 units, from SI to traditional](https://amperis.com/en/resources/tools/unit-converter/) - [IEC 61620:1998 calculator: tan δ and conductivity of insulating liquids](https://amperis.com/en/resources/tools/insulating-liquid-tan-delta-conductivity-calculator/) - [Coordinate converter: decimal degrees, DMS and UTM (WGS84, ETRS89 and ED50)](https://amperis.com/en/resources/tools/coordinate-converter/) - [World time zone map: the official time in every country right now](https://amperis.com/en/resources/tools/world-time-zone-map/) - [Battery life forecast: state of health (SOH) and remaining life calculator](https://amperis.com/en/resources/tools/battery-state-of-health-soh-calculator/) - [High-voltage circuit-breaker diagnostics: timing, contact resistance, coils and SF6](https://amperis.com/en/resources/tools/high-voltage-circuit-breaker-diagnostics/) - [Power transformer test calculator to IEC 60076-1:2011](https://amperis.com/en/resources/tools/power-transformer-test-calculator-iec-60076-1/) - [Electric motor calculator to IEC 60034-1:2022](https://amperis.com/en/resources/tools/electric-motor-calculator-iec-60034-1/) - [MCP server: the Amperis catalogue in your AI assistant](https://amperis.com/en/resources/mcp-server/) - [How to migrate a Nexus 1250 with I/O modules to a Nexus 1450](https://amperis.com/en/resources/articles/migrating-a-nexus-1250-with-io-modules-to-a-nexus-1450/) - [Battery ES Tech Europe 2026: Amperis and the full battery life cycle](https://amperis.com/en/resources/news/battery-es-tech-europe-2026/) - [Video: AHZAQ – Product](https://amperis.com/en/resources/videos/ahzaq-product/) - [Video: AHZAQ – Technical guide](https://amperis.com/en/resources/videos/ahzaq-technical/) - [Video: AMIC-10](https://amperis.com/en/resources/videos/amic-10/) - [Video: AMIC-10K1](https://amperis.com/en/resources/videos/amic-10k1/) - [Video: AMIC-15K1](https://amperis.com/en/resources/videos/amic-15k1/) - [Video: AMIC-2505](https://amperis.com/en/resources/videos/amic-2505/) - [Video: AMIC-30](https://amperis.com/en/resources/videos/amic-30/) - [Video: AMIC-5005](https://amperis.com/en/resources/videos/amic-5005/) - [Video: AMPI-520](https://amperis.com/en/resources/videos/ampi-520/) - [Video: AMPI-525](https://amperis.com/en/resources/videos/ampi-525/) - [Video: AMPI-530-IT](https://amperis.com/en/resources/videos/mpi-530-it/) - [Video: AMPI-540](https://amperis.com/en/resources/videos/mpi-540/) - [Video: AMRU-10](https://amperis.com/en/resources/videos/amru-10/) - [Video: AMRU-200](https://amperis.com/en/resources/videos/amru-200/) - [Video: AMRU-200 GPS](https://amperis.com/en/resources/videos/amru-200-gps/) - [Video: AMZC-304](https://amperis.com/en/resources/videos/amzc-304/) - [Video: AMZC-305](https://amperis.com/en/resources/videos/amzc-305/) - [Video: AMZC-310S](https://amperis.com/en/resources/videos/amzc-310s/) - [Video: APD-ANNUNCIATOR – Product](https://amperis.com/en/resources/videos/apd-annunciator-product/) - [Video: APD-ANNUNCIATOR – Technical guide](https://amperis.com/en/resources/videos/apd-annunciator-technical/) - [Video: APQM-700](https://amperis.com/en/resources/videos/apqm-700/) - [Video: APQM-702/703](https://amperis.com/en/resources/videos/apqm-702-703/) - [Video: APQM-707](https://amperis.com/en/resources/videos/apqm-707/) - [Video: BLU-D](https://amperis.com/en/resources/videos/blu-d/) - [Video: CAB](https://amperis.com/en/resources/videos/cab/) - [Video: CoroCAM UVS](https://amperis.com/en/resources/videos/corocam-uvs/) - [Video: D-TEK](https://amperis.com/en/resources/videos/d-tek/) - [Video: HPS-HV](https://amperis.com/en/resources/videos/hps/) - [Video: HZJD-2Z](https://amperis.com/en/resources/videos/hzjd-2z/) - [Video: IR DLD-T](https://amperis.com/en/resources/videos/dld-t/) - [Video: IR-DLD-TS – Product](https://amperis.com/en/resources/videos/dld-ts-product/) - [Video: IR-DLD-TS – Technical guide](https://amperis.com/en/resources/videos/dld-ts-technical/) - [Video: IR-SF641](https://amperis.com/en/resources/videos/ir-sf641/) - [Video: Rapidox 1100Z](https://amperis.com/en/resources/videos/rapidox-1100z/) - [Video: RMM – Product](https://amperis.com/en/resources/videos/rmm-product/) - [Video: RMM – Technical guide](https://amperis.com/en/resources/videos/rmm-technical/) - [Video: RMO-G](https://amperis.com/en/resources/videos/rmo-g/) - [Video: RMO-H](https://amperis.com/en/resources/videos/rmo-h/)