WEBVTT

00:00:00.502 --> 00:00:04.219
How a 100 microphones turn a
sound into a place on a picture,

00:00:04.259 --> 00:00:07.915
and how to run a leak survey
and a discharge survey with it.

00:00:11.629 --> 00:00:13.491
A leak in a compressed air line,

00:00:13.531 --> 00:00:16.939
and a discharge on an insulator,
have something in common:

00:00:16.979 --> 00:00:19.436
both of them are making a sound right now.

00:00:19.476 --> 00:00:22.646
You cannot hear either of
them, and even if you could,

00:00:22.686 --> 00:00:24.786
the plant around them is far louder.

00:00:29.353 --> 00:00:33.420
The way round it is where you
listen. Plant noise is loud but low:

00:00:33.460 --> 00:00:35.597
it collapses above a few kilohertz.

00:00:35.637 --> 00:00:37.837
A gas escaping through a small hole,

00:00:37.877 --> 00:00:41.446
and an electrical arc, both
keep radiating far above that.

00:00:41.486 --> 00:00:44.620
Put the listening window
up in the ultrasonic band,

00:00:44.660 --> 00:00:48.913
and the noise is gone while the
thing you are hunting is still there.

00:00:54.485 --> 00:00:58.899
And the way it is located is simple
arithmetic done a great many times.

00:00:58.939 --> 00:01:03.165
A 112 microphones hear the same
sound at slightly different moments.

00:01:03.205 --> 00:01:07.368
Shift each one by the delay that
would come from a given direction,

00:01:07.408 --> 00:01:11.320
add them up, and only the sound
from that direction reinforces.

00:01:11.360 --> 00:01:15.837
Do that for every direction in the
field of view, and you have an image.

00:01:21.286 --> 00:01:23.823
For leaks, it does not
stop at finding them.

00:01:23.863 --> 00:01:27.981
It estimates how much is escaping,
and what that costs you over a year.

00:01:30.903 --> 00:01:33.683
For electrical work it
does something else.

00:01:33.723 --> 00:01:37.488
It builds a phase-resolved
discharge pattern in real time,

00:01:37.528 --> 00:01:42.276
and classifies what it is seeing into
corona, surface, floating or noise.

00:01:45.881 --> 00:01:50.523
And it was made to be carried round a plant
all day rather than set up on a tripod.

00:01:54.578 --> 00:01:57.401
The sensitivity is what
makes the range possible.

00:01:57.441 --> 00:02:01.724
Down at about one decibel of sound
pressure across the middle of the band,

00:02:01.764 --> 00:02:06.047
which is why a leak of half a litre a
minute is visible from across a bay.

00:02:10.039 --> 00:02:12.029
Everything you find leaves with you.

00:02:12.069 --> 00:02:14.003
Images, video and the sound itself,

00:02:14.043 --> 00:02:17.105
tagged with where you were
standing when you took them.

00:02:21.654 --> 00:02:23.934
And the numbers, for the specification.

00:02:26.435 --> 00:02:28.590
Start with what is in your hands.

00:02:28.630 --> 00:02:31.183
The whole front face is the instrument:

00:02:31.223 --> 00:02:34.442
a 112 microphones in a
disc, an optical camera in

00:02:34.482 --> 00:02:37.900
the middle of them, a distance
sensor and two lamps.

00:02:37.940 --> 00:02:40.693
Everything else is a screen and a battery.

00:02:45.007 --> 00:02:48.337
Three ports, and each one is
there for a different job.

00:02:48.377 --> 00:02:52.443
The audio output is the one people
forget, and it is worth knowing:

00:02:52.483 --> 00:02:54.404
it lets you hear the ultrasound,

00:02:54.444 --> 00:02:57.774
shifted down into the range
your ears actually work in.

00:03:01.695 --> 00:03:06.033
Before touching a setting, it helps
to know what the instrument is doing.

00:03:06.073 --> 00:03:10.531
The microphones all hear the same sound,
but at slightly different moments.

00:03:10.571 --> 00:03:14.489
Delay each one by the amount that
a given direction would produce,

00:03:14.529 --> 00:03:17.727
add them together, and only
that direction reinforces.

00:03:17.767 --> 00:03:20.606
Repeat for every direction
in the field of view.

00:03:26.895 --> 00:03:30.064
The main screen has 7 areas
and you will use 4 of them.

00:03:30.104 --> 00:03:34.441
Down the left is the quick settings
strip, across the top the level and the

00:03:34.481 --> 00:03:38.992
distance, and down the right the frequency
analysis with the two band handles.

00:03:44.177 --> 00:03:47.364
The first choice is how many
sources you want to see,

00:03:47.404 --> 00:03:49.678
and it changes what the screen is for.

00:03:49.718 --> 00:03:52.114
One source for hunting, 3 for comparing,

00:03:52.154 --> 00:03:55.646
and the full heat map for
surveying a whole panel at once.

00:04:00.483 --> 00:04:05.022
The second choice is the one that
decides whether the survey works at all:

00:04:05.062 --> 00:04:08.426
the frequency band. Audible
and ultrasonic are presets.

00:04:08.466 --> 00:04:12.943
User lets you drag the two handles
yourself, and the technique is simple:

00:04:12.983 --> 00:04:18.017
raise the lower handle until the plant
disappears from the screen, and no further.

00:04:22.874 --> 00:04:25.154
Then two settings that people confuse.

00:04:25.194 --> 00:04:28.145
Image range changes the
span of the colour scale.

00:04:28.185 --> 00:04:30.770
Display threshold
decides how quiet a sound

00:04:30.810 --> 00:04:33.517
has to be before the
camera stops drawing it.

00:04:33.557 --> 00:04:36.508
Raise the threshold and
the picture gets cleaner,

00:04:36.548 --> 00:04:40.110
but you will also stop seeing
the faint thing you came for.

00:04:46.817 --> 00:04:51.001
For leak work, the instrument needs to
know what your leak actually costs,

00:04:51.041 --> 00:04:53.456
and that means telling
it about your plant.

00:04:53.496 --> 00:04:57.394
For compressed air it wants the
compressor and the electricity price.

00:04:57.435 --> 00:05:00.477
For a bought gas, it simply
wants the price per litre.

00:05:06.805 --> 00:05:08.569
And then the measurement itself,

00:05:08.609 --> 00:05:11.502
which has one rule that
matters more than any other:

00:05:11.542 --> 00:05:13.870
put the leak in the middle of the picture.

00:05:13.910 --> 00:05:16.803
The estimate is calculated
from the distance and the

00:05:16.843 --> 00:05:19.904
level at that point, and
off-centre it is simply wrong.

00:05:23.042 --> 00:05:27.812
Partial discharge work has its own rule,
and it is just as easy to get wrong:

00:05:27.852 --> 00:05:29.685
set the mains frequency first.

00:05:29.725 --> 00:05:33.371
The whole pattern is built
against the phase of the supply,

00:05:33.411 --> 00:05:37.618
so on a 50 hertz network a camera
left at 60 will classify nonsense.

00:05:44.040 --> 00:05:48.431
Files, and the habit worth forming
before you start rather than after.

00:05:48.471 --> 00:05:51.532
Create the folder for the
job first, and name it.

00:05:51.572 --> 00:05:55.013
21 gigabytes is a lot of
survey to sort out afterwards.

00:06:01.028 --> 00:06:03.660
And the app, which is
what turns a folder of

00:06:03.700 --> 00:06:06.331
pictures into a report
with locations on it.

00:06:08.191 --> 00:06:10.389
Finally, the little it asks of you.

00:06:10.429 --> 00:06:14.161
One of these is worth doing at
the start of every campaign:

00:06:14.201 --> 00:06:19.467
the microphone self-test. A 112 microphones
is a lot of things to go quietly wrong.

00:06:24.807 --> 00:06:26.925
Acoustic imaging, from Amperis.