The APQM-707, a class S
analyzer that is configured,

00:00:06.180 --> 00:00:08.480
read and reported on its own touchscreen.

00:00:08.520 --> 00:00:12.920
How it is connected, what it checks,
and what it does beyond recording.

00:00:16.240 --> 00:00:21.180
A trip, a flickering light, or a hot
cable needs an answer on the spot.

00:00:21.220 --> 00:00:24.780
The APQM-707 is built for that.

00:00:24.820 --> 00:00:28.280
Connect it, look at the waveforms
and harmonics on the screen,

00:00:28.320 --> 00:00:32.240
record if needed, and leave with
the report, without a laptop.

00:00:37.900 --> 00:00:44.900
S to IEC 61000-4-30. 5 voltage
inputs up to 760 volts,

00:00:44.940 --> 00:00:48.360
and 4 current inputs
with clamps up to 6 kA.

00:00:48.400 --> 00:00:53.900
A 7-inch touchscreen, and a memory card
that holds more than 10 years of recording.

00:01:00.700 --> 00:01:04.760
All sockets are on the top edge,
4 current inputs on the left,

00:01:04.800 --> 00:01:10.620
and the voltage inputs L1, L2,
L3, N, and PE on the right.

00:01:10.660 --> 00:01:14.960
Two buttons only, one to switch
on, and one to start recording.

00:01:15.000 --> 00:01:19.600
Everything else is on the touchscreen,
with a stylus for gloved hands.

00:01:24.480 --> 00:01:29.100
The live mode shows waveforms,
a running RMS plot,

00:01:29.140 --> 00:01:32.760
tables, the phaser diagram,
and the harmonic bars.

00:01:33.080 --> 00:01:35.420
Configurations are
created on the instrument,

00:01:35.460 --> 00:01:42.480
from a standard profile such as EN 50160 or
from scratch, and saved for the next job.

00:01:48.080 --> 00:01:49.600
measurement takes five steps.

00:01:49.640 --> 00:01:53.400
Connect the network. Choose
or create the configuration.

00:01:53.440 --> 00:01:55.020
Check the connection icon.

00:01:55.060 --> 00:01:55.980
Press start.

00:01:56.020 --> 00:02:01.040
And when the recording ends, analyze it
and generate the report on the instrument.

00:02:08.850 --> 00:02:12.490
a four-wire network, connect
N and the three phases.

00:02:12.530 --> 00:02:17.230
PE goes to the protective conductor if
the neutral to earth voltage is wanted.

00:02:17.270 --> 00:02:20.370
Then the three clamps,
arrows towards the load,

00:02:20.410 --> 00:02:23.650
and a fourth on the neutral
for the total apparent power.

00:02:27.750 --> 00:02:32.430
a three-wire network, the voltages of
this analyzer are referenced to PE.

00:02:32.470 --> 00:02:38.210
So PE goes to earth, and L1,
L2, and L3 go to their phases.

00:02:38.250 --> 00:02:40.290
The N input is left free.

00:02:40.330 --> 00:02:42.250
Then one clamp per phase.

00:02:45.430 --> 00:02:47.850
icon on the top bars
sums up the connection.

00:02:47.890 --> 00:02:51.950
Tap it, and a window lists
voltages, currents, voltage,

00:02:51.990 --> 00:02:55.290
and current angles and frequency,
each with its own mark.

00:02:55.330 --> 00:02:59.750
A reversed clamp or a swapped phase
shows up before the recording starts.

00:03:06.350 --> 00:03:09.730
analyzer also measures the
efficiency of an inverter.

00:03:10.030 --> 00:03:13.710
For a single-phase output, the
DC plus goes to the N input

00:03:13.750 --> 00:03:19.490
and DC minus to L3. The AC
side goes between L1 and PE.

00:03:19.530 --> 00:03:24.130
A DC clamp on the IN channel
measures the input current,

00:03:24.170 --> 00:03:27.190
and a second clamp on L1 the output.

00:03:31.280 --> 00:03:35.760
For motors and transformers, the
inrush mode waits for the current to

00:03:35.800 --> 00:03:40.740
cross a threshold, set by default at one
and a half times the nominal current,

00:03:40.780 --> 00:03:44.380
then records five to sixty seconds
with one second of pre-trigger.

00:03:44.420 --> 00:03:50.460
It gives the maximum half-cycle RMS and the
Joule integral to choose the protection.

00:03:54.140 --> 00:03:56.460
Recordings are analyzed on the instrument.

00:03:56.500 --> 00:04:01.000
Time plots of up to four parameters,
the event list with waveforms,

00:04:01.040 --> 00:04:06.500
harmonic graphs, and a report on
compliance with EN 50160. The energy cost

00:04:06.540 --> 00:04:10.920
calculator and the energy losses
calculator turn the data into money.

00:04:10.960 --> 00:04:14.420
Reports go to a USB stick as PDF,

00:04:20.490 --> 00:04:23.750
measuring Category 4 at 600 volts.

00:04:23.790 --> 00:04:29.710
An IP51 case with a folding lid, a
lithium-ion battery for at least four hours,

00:04:29.750 --> 00:04:34.810
about six in typical use,
charged in two, and 1.75 kilos.

00:04:40.640 --> 00:04:43.840
Troubleshooting in industrial
and commercial networks,

00:04:43.880 --> 00:04:46.380
energy audits with cost calculation,

00:04:46.480 --> 00:04:50.160
commissioning of photovoltaic
installations and their inverters,

00:04:50.200 --> 00:04:54.500
and day-to-day work for maintenance
teams and power quality consultants.

00:04:58.200 --> 00:05:01.300
Power Quality Analysis from Amperis.