Insulation Resistance Meter
HIGHEST ACCURACY & LOWEST COST
AMIC-10
Insulation resistance measurement: 50, 100, 250, 500 or 1000 V. 10GΩ.
Low voltage resistance measurement. AC/DC voltage measurement 0...600V.
Capacitance measurements.
AMPERIS PRODUCTS S.Lagricultura, 34, Contact 27003 Agricultura,34 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, Spain info@amperis.com | www.amperis.com
Main characteristics are the following:
Insulation resistance measurement:
- Measurement voltage: 50, 100, 250, 500 or 1000 V
- Continuous indication of insulation resistance or leakage current
- Automatic discharge of capacitance of tested object after the insulation resistance measurement
- Acoustic signaling of five-second periods to facilitate obtaining time characteristics
- Indication of actual test voltage during the measurement
- Protection against measuring live objects
- Three-lead measurement
Continuity measurement of protective and equipotential conductors according to EN 61557-4 with the >200mA current.
Low-voltage circuit continuity and resistance measurement:
- Circuit resistance measurement (<1999Ω) with <15mA current
- Quick sound signal if circuit resistance is below 30. Capacitance measurement during the RISO measurement Measurement of alternating and direct voltages in the 0...600V range Power supply: 4 AA or rechargeable batteries, monitoring of power supply voltage.
Continuity measurement of protective and equipotential conductors with the 200mA current Measuring range according to EN 61557-4: 0,10...1999Ω
| Range | Resolution | Accuracy |
|---|---|---|
| 0,00...19,99Ω | 0,01Ω | ±(2% m.v. + 3 digits) |
| 20,0...199,9Ω | 0,1Ω | ±(2% m.v. + 3 digits) |
| 200...1999Ω | 1Ω | ±(4% m.v. + 3 digits) |
| Voltage on open terminals: <8V Output current at R <2Ω: ISC >200mA. Compensation of test leads’ resistance. Unidirectional current flow. |
| Low-voltage and resistance measurement | |
|---|---|
| Range Resolution | Accuracy |
| 00,0...199,9Ω 0,1Ω | ±(3% m.v. + 3 digits) |
| 200...1999Ω 1Ω | ±(3% m.v. + 3 digits) |
| Voltage on open terminals: <8V. Current for closed terminals5mA < ISC << 15mA . Sound signal and green LED on when measured resistance < 30Ω ± 50%. Compensation of test leads’ resistance. |
Capacitance measurements
| Range | Resolution Accuracy |
|---|---|
| 1...999nF 1,00...9,99μF | 1nF ±(5% m.v. +5 digits) 0,01μF |
| Capacitance value displayed during the RIS | SO measurement. |
| IS For test voltages below 100V and measure | SO ed resistance below 10MΩ, unspecified capacitance measurement error. “m.v.” = “measured value”. |
Insulation resistance measurement:
Measuring range according to EN 61557-2 for UN =50V: 50kΩ...250,0MΩ
| Range Resolution | Accuracy |
|---|---|
| 0,0...999,9kΩ 0,1kΩ | |
| 1,000...9,999MΩ 0,001MΩ | ±(3%.m.v. + 8 digits) |
| 10,0...99,99MΩ 0,01MΩ | ±(3%.m.v. + 8 digits) |
| 100,0...250,0MΩ 0,1MΩ | |
| 100,0...250,0MΩ 0,1MΩ Measuring range according to EN 61557-2 for UN =100V: 100kΩ...500,0MΩ | |
| Range Resolution | Accuracy |
| 0,0...999,9kΩ 0,1kΩ | |
| 1,000...9,999MΩ 0,001MΩ | ±(3%.m.v. + 8 digits) |
| 10,0...99,99MΩ 0,01MΩ | ±(3%.m.v. + 8 digits) |
| 100,0...500,0MΩ 0,1MΩ | |
| Measuring range according to EN 61557-2 for UN =250V: 250kΩ...2000,0MΩ | |
| Range Resolution | Accuracy |
| 0,0...999,9kΩ 0,1kΩ | |
| 1,000...9,999MΩ 0,001MΩ | |
| 10,0...99,99MΩ 0,01MΩ | ±(3%.m.v. + 8 digits) |
| 100,0..999,9MΩ 0,1MΩ | |
| 1000,0..2000,0MΩ 1MΩ | |
| 1000,0..2000,0MΩ 1MΩ Measuring range according to EN 61557-2 for UN =500V: 500kΩ...5000,0MΩ | |
| Range Resolution | Accuracy |
| 0,0...999,9kΩ 0,1kΩ | |
| 1,000...9,999MΩ 0,001MΩ | ±(3%.m.v. + 8 digits) |
| 10,0...99,99MΩ 0,01MΩ | ±(3%.m.v. + 8 digits) |
| 100,0..999,9MΩ 0,1MΩ | |
| 1000,0..5000,0MΩ 1MΩ | ±(4%.m.v. + 6 digits) |
| Measuring range according to EN 61557-2 for UN =1000V: 1000kΩ...10,0GΩ | |
| Range Resolution | Accuracy |
| 0,0...999,9kΩ 0,1kΩ | |
| 1,000...9,999MΩ 0,001MΩ | ±(3%.m.v. + 8 digits) |
| 10,0...99,99MΩ 0,01MΩ | ±(3%.m.v. + 8 digits) |
| 100,0..999,9MΩ 0,1MΩ | |
| 1000,0..5000,0MΩ 1MΩ | ±(4%.m.v. + 6 digits) |
| 5,0..10,0GΩ 0,01GΩ | ±(4%.m.v. + 6 digits) |
| Measurement of AC/DC voltage | |
| Range Resolution | Accuracy |
| 0,0...299,9V 0,1V | ±(2%m.v. + 6 digits) |
| 300...600V 1V | ±(2%m.v. + 2 digits) |
| Frequency range: 45...65Hz. |
AMPERIS PRODUCTS S.Lagricultura, 34, 27003 Agricultura,34 lugo [spain]27003, Lugo, Spain
AMIC-10 Specifications Electric security: Type of insulationDouble, acc. to EN 61010-1 and IEC 61557 Measurement categoryCAT IV 600V acc. to EN 61010-1 Protection class acc. to EN 60529IP67 Other technical data: Power suply4 alkaline batteries or battery package Ni-MH Weight1kg Dimensions220 x 100 x 60 mm
Standard accesories:
“Crocodile” clip K01; black Test lead with banana plug; 1,2m; red Test lead with banana plug; 1,2m; blue Pin probe with banana connector; black Pin probe with banana connector; red Carrying case M6 Hanging straps Handle to suspend the meter Certificate calibration Battery set
Optional accesories:
Test lead with banana plug 5m; red Test lead with banana plug 5m; blue Shielded test lead with banana plug; 5m; black Test lead with banana plug 1,2m; blue “Crocodile” clip K02; red “Crocodile” clip K01; black “Crocodile” clip K02; blue Pin probe with banana connector; blue Adapter WS-04 with UNI-Schuko
AMPERIS PRODUCTS S.Lagricultura, 34, Contact 27003 Agricultura,34 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, Spain info@amperis.com | www.amperis.com