Amperis battery regenerator Universal Battery Charger/Discharger/Analyzer
- Quick regenerations
- Expanded lifespan of batteries •The Most Energy Efficient technology available. •Universal charger for all types of batteries (multivoltage, multi-layer and multi-chemical)
The objective of the equipment is to increase the useful life of the battery avoiding the loss of capacity by eliminating the sulfation with success The Amperis Battery Regenerator combines the efficiency of the universal and programmable MMF charger, with the reliabity of the Amperis battery discharger. It works with batteries of any type and supports applications of any type (formation, conditioning, recovery, desulphation and regeneration). It has a very complete set of charging curves. In addition, the user can program new curves in a simple way.
Applications:
- Eliminate battery sulphation
- Battery formation and testing.
- Conditioning and analysis of batteries.
Optional equipment:
- Submersible probe for battery temperature.
- Enclosure type IP54 or NEMA 3R.
- Extended data-logger with miniUSB port or Bluetooth.
- Starter batteries, stationary batteries, traction batteries, Ni-Cad batteries
Technical specifications of the MMF charger:
| AC INPUT | AUTOMATIC SHUTDOWN | The charger is switched off (<3s) in case of disconnection of the battery during the charging | |
|---|---|---|---|
| TYPE | MMF Universal Battery Charger | AUTOMATIC SHUTDOWN | disconnection of the battery during the charging |
| TYPE | MMF Universal Battery Charger | AUTOMATIC SHUTDOWN | disconnection of the battery during the charging process. |
| STANDARD VOLTAGES | Single-phase 220-230-240 VAC ± 10% Three-phase 220-240, 400, 440, 480, 600 VAC ± 10% Frequency 50/60 Hz ± 5 Hz | ON BATTERY | An independent safety timer turns the charger off in case of malfunction of the control panel. |
| EFFICIENCY | Frequency 50/60 Hz ± 5 Hz >90% | MECHANICAL AND E | ENVIRONMENTAL CHARACTERISTICS |
| EFFICIENCY POWER FACTOR | >90% >90% | DIMENSIONS (W x H x D mm) | CABINET A: 500 x 900 x 440 (mm) CABINET B: 620x 1050 x 550 (mm) |
| DC OUTPUT | ENCLOSURE TYPE | Steel enclosure. | |
| STANDARD VOLTAGES | From single battery cell to 600 VDC. | COOLING | FORCED VENTILATION with active fan control. |
| CURRENT RATINGS | From 50A to 500A | AUDIBLE NOISE | < 65 dBA at 1 meter. IP21 (Standard) |
| CHARGING CURVE | Completely configurable by the user. PROTECTION | ENCLOSURE PROTECTION | IP21 (Standard) IP54 (Optional) |
| PROTECTION | AMBIENT TEMPERATURE | Operation: -10/+50 ºC | |
| WRONG BATTERY AND REVERSE POLARITY | The charger remains in stand-by mode and gives an error message. | AMBIENT TEMPERATURE | Operation: -10/+50 ºC Storage: -10/+70 ºC |
| AND REVERSE POLARITY ELECTRONIC OVERLOAD | error message. | ALTITUDE | < 2000 m (According to EN62040-3) |
| ELECTRONIC OVERLOAD PROTECTION | Complete protection in case of output short circuit or overload. | USER INTE USER INTERFACE | ERFACE AND CONNECTIVITY LCD Display + LEDs, keyboard and audible alarm. |
| PROTECTION | overload. WITHOUT AUXILIARY WIRES: When the battery is | USER INTERFACE | LCD Display + LEDs, keyboard and audible alarm. AInternal storage of 200 cycles (expandable to 600 |
| ANTI-ARCING | WITHOUT AUXILIARY WIRES: When the battery is connected, no arcing is generated at the connectors. If the battery is disconnected while it’s being charged, arcing is possible, (it’s necessary to turn off the charger before to disconnect the battery). | CONNECTIVITY | AInternal storage of 200 cycles (expandable to 600 with miniUSB, optional) BLUETOOTH Wireless extension. |
| ANTI-ARCING | before to disconnect the battery). WITH AUXILIARY WIRES (RECOMMENDED): Full | STANDARDS | |
| WITH AUXILIARY WIRES (RECOMMENDED): Full Anti-arcing protection in case of battery | QUALITY | ISO 9001:2015 | |
| Anti-arcing protection in case of battery disconnection, even while the charge is in progress. | MARKING | CE | |
| POWER-ON SELF-TEST | Self-test at each power-up (<10s). In the event of an error, an error message is displayed. | EMC | IEC EN 61000-6-2, IEC EN 61000-6-4 |
| BLACK-OUT FOR BATTERY DISCONNECTION | Smart management of AC input blackouts, resetting to the exact point by completing the charging cycle. Data saved in the history log. |
AMPERIS PRODUCTS S.Lagricultura, 34, Contacto 27003 Agricultura,34 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, España info@amperis.com | www.amperis.com
| Technical TYPE | specifications of the discharger: POWER SUPPLY Automatic battery discharger |
|---|---|
| TYPE | Automatic battery discharger |
| NOMINAL TENSION RANGE | 85-135 ó 180-250VAC single-phase |
| MAXIMUM POWER | 250W, 50/60 Hz |
| MECH DIMENSIONS (A x L x P mm) | HANICAL CHARACTERISTICS 325x560x550 |
| ENCLOSURE TYPE | 2 mm steel enclosure. With 4 wheels for easy transportation RAL 7032 |
| REFRIGERATION | Forced ventilation. |
| CO | ONTROL AND MEASURE |
| USER INTERFACE | Digital display with: battery voltage (V), battery current (A), discharged capacity (Ah), programmed test stop voltaje and programmed discharge time. |
| CONTROLS | Three buttons (SET, +, -) for programming and control. Two potentiometers for current regulation. |
| MAXIMUM DISCHARGE TIME | 48h |
| PC INTERFACE | RS-232, USB (upon request), PC TrendCom software for data capture, analysis and printing. |
| SAFETY | IEC EN 50178, IEC EN 62040-1 |
|---|---|
| TEST RUN | IEC EN 62040-3 |
| NORTH AMERICAN STANDARDS | UL 1564 “Industrial Battery Chargers” CSA 22.2 107.2-01 “Battery Chargers” cCSAus Listed |
NOTE: Reported Efficiency and Power Factor values are AVERAGE values, measured over the entire charging cycle. Peak Efficiency and Power Factor are higher.
Screenshot of the battery discharger software.
The following table shows all available models of the MMF battery charger:
In this table the models of the discharger are reflected according to the voltage of the battery:
| MODEL | VOLTAGE | CURRENT |
|---|---|---|
| A-00 | 0-48V | 0-50A |
| A-50 | 2-48V | 0-50A |
| A-100 | 2-48V | 0-1OOA |
| A-150 | 2-48V | 0-150A |
| A-200 | 2-48V | 0-200A |
| A-300 | 2-48V | 0-300A |
| B-00 | 0-80V | 0-50A |
| B-50 | 2-80V | 0-50A |
| B-100 | 2-80V | 0-1OOA |
| B-150 | 2-80V | 0-150A |
| C-00 | 0-96V | 0-50A |
| C-50 | 2-96V | 0-50A |
| C-100 | 2-96V | 0-1OOA |
| C-150 | 2-96V | 0-150A |
| C-200 | 2-96V | 0-200A |
| D-00 | 0-200V | 0-80A |
| D-80 | 50-200V | 0-80A |
| E-00 | 0-400V | 0-50A |
| E-50 | 50-400V | 0-50A |
| MODELOS | ESTANDAR |
|---|---|
| TENSIÓN DE LA BATERÍA | CORRIENTE DE DESCARGA MÁXIMA |
| 12-48V | 100A |
| 12-48V | 200A |
| 12-96V | 200A |
| 24-135V | 150A |
| 48-220V | 75A |
For other configurations, contact the Amperis offices.