Skip to content

Accessible version

BVS

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 10 pages · 449 KB)

Battery Voltage Supervisor

  • Automated string and cell voltage, string current and ambient temperature and cell temperature measurements during capacity tests
Image: DV Power BVS battery voltage supervisor control unit alongside its handheld remote module.
  • Detection and notification of failing cells
  • Reliable and easy to operate
  • Detailed test analysis and reporting provided using DV-B Win software
  • Two models: BVS and BVS-4 (1 module per 4 cells)
  • Cell temperature measurement

Description

The Battery Voltage Supervisor is a battery monitoring system for real-time data gathering and viewing.

This system’s main role is monitoring battery voltage values during a battery discharge testing in order to meet IEC, IEEE and NERC requirements.

The Battery Voltage Supervisor is an integrated system consisting of:

  • Control Unit for BVS or BVS-4 (BVS-CU)
  • Cell Voltage Modules (CVM or CVM-4)
  • BVS-4 – One cell voltage module (CVM4) is connected to 4 cells and measures the voltage of each cell

BVS and BVS-4 systems act as an add-on to the Battery Load Unit (BLU) series of devices while performing a battery discharge test, providing detailed analysis of an individual cell’s condition. The system identifies a potential battery malfunction by monitoring the cell voltage parameters from an array of the cell voltage module.

  • String voltage module (SVM) (optional)
  • String current module (SCM) (optional)

The BVS-CU performs monitoring and measurements data acquisition from the Cell Voltage Modules and transfers this data to a PC. In addition, the BVS-CU provides power supply to all connected modules. Cell Voltage modules are used to measure cell parameters.

Depending on the type of cell voltage modules used, DV Power provides two models of Battery Voltage Supervisors:

  • BVS – One cell voltage module (CVM) measures one cell

In addition, the BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current measurements can be achieved by using optional string voltage module (SVM) and string current module (SCM).

The Cell Voltage Modules detect cells that fail a discharge test based on measured voltage values, so these cells can be safely removed from the battery string.

Data acquisition and extensive analysis capabilities of data collected from the modules is available in the DV–B Win application software suite, providing a user data viewing, tracking and generation of comprehensive reports.

Applications

The list of the instrument applications includes:

  • Real time cell condition assessment by monitoring and recording cell voltages from the set modules during a battery capacity (discharge) testing as well as charging procedure.
  • Real time ambient temperature monitoring with the BVS-CU unit
  • Cell temperature measurement
  • String voltage and current monitoring using additional string voltage module (SVM) and string current module (SCM)
  • Detailed data trending and analysis provided using DV-B Win software

Battery Voltage Supervisor BVS

In the BVS system implementation, every CVM module is installed directly on an individual cell. Each cell voltage module measures parameters of one cell. Measured parameters are:

  • Cell Voltage

Failure of one of the CVM modules will not affect communication between the rests of operating CVM modules and the BVS-CU. The connection diagram of the BVS to a battery string is presented in the figure below.

  • Intercell connection voltage
  • Cell temperature (optional)
Image: Connectivity diagram of BVS system components in combination with Battery Load Unit device

Battery Voltage Supervisor BVS-4

In the BVS-4 system implementation, every CVM-4 module is installed to monitor up to 4 cells. Measured parameters are:

  • Cell Voltage
  • Cell temperature (optional) – on one of the 4 cells

Failure of one of the CVM-4 modules will not affect communication between the rests of operating CVM-4 modules and the BVS-CU. The connection diagram of the BVS-4 to a battery string is presented in the figure below.

This simplifies the connection to the battery string, since a fewer number of connections is required.

Image: Connection diagram of BVS-4 system components in combination with Battery Load Unit device

Features and Benefits

Extensive cell analysis during discharge test

DV-B Win Software

Using the BVS/BVS-4 as a supplement to the Battery Load Unit (BLU) devices provides multiple advantages during a battery discharge testing.

The Cell Voltage Modules measure voltage values in real-time mode and forward recorded data to the Control Unit in user defined intervals selected through DV-B Win application software. All out-of-tolerance measurement values are announced by a LED signalization on individual modules, so the failing cells can be detected before endangering the entire battery system. This enables detecting and safely bypassing the failing cell during a discharge process.

All results transferred from the BVS/BVS-4 system can be viewed, analyzed and presented in selectable report forms by using the DV-B Win software application.

Data can be transferred to a PC through USB or Bluetooth communication.

Both, the BVS/BVS-4 and the BLU device provided results can be viewed on the same report form.

A quick pass/fail test for a cell internal resistance values may be performed based on a user defined thresholds, adding additional insight in an individual cell’s status.

Up to 4 ambient temperature measurement channels are provided on the BVS-CU for measuring ambient temperature on multiple locations. Additional two modules can used in case string voltage and current measurements are required. Using these two optional modules enables the system to work in conjunction with any load bank on the market and perform completely automated capacity test.

ModelBVS (CVM)BVS-4 (CVM-4)
Measured parametersCell voltage Intercell voltage String current (with SCM) String voltage (with SVM) Ambient temperature Cell temperature (optional)Cell voltage + Intercell voltage String current (with SCM) String voltage (with SVM) Ambient temperature Cell temperature (optional) – 1 temperature measurement channel per module
Number of cells per module14
Measurement rangeCell voltage: 30 V Intercell voltage: 50 mVVoltage: 30 V per channel (1 CVM-4 has 4 voltage measurement channels)
Sample rate1 sec max (depends on number of CVM)1 sec max (depends on number of CVM-4)

DV-B Win Main Features

  • Full control of the BVS/BVS-4 from a PC or a BLU-C unit
  • Both discharge results from BLU device and cell voltage values from the Cell Voltage Modules can be previewed in one DV-B Win file
  • Acquisition and detailed analysis of measured data
  • String voltage, Cell voltage and internal resistance trending
  • Test report for BLU and BVS/BVS-4 are available in several formats (Excel spreadsheet, pdf, word or RTF)
  • User selected sampling time of CVM/CVM-4
Image: Battery monitoring software screen listing cell voltages and temperatures, with a bar chart of voltage for each cell in the string.

DV-B Win features: String View (BLU) & Cell View (BVS/BVS-4) functions

Technical Data

Mains Power Supply

  • Input voltage: 90 – 264 V AC, 50/60 Hz
  • Input power: 110 VA
  • CVM/CVM-4 supply voltage: 66 V DC

Measurement

  • Maximum relative humidity: 95 % for temperatures up to 31 °C/88 F, decreasing linearly to 40 % relative humidity at 55 °C/131 F

Dimensions and Weight

  • Dimensions (L x W x D):

BVS-CU: 206 mm x 180 mm x 64 mm

ParametersMeasuring rangeResolution
Cell Voltage± 30 V DC1 mV μ
String Voltage± 600 V1 mV μ
String Current± 1 V0,1 μV μ
Intercell connection Voltage (CVM)*± 50 mV DCμ 1 μV
  • Typical accuracy:

±50 mV DC (only for CVM): ± (1% rdg + 1% F.S)* ±1 V DC (for SCM): ± (0,1% rdg + 0,1% F.S)

  • ±30 V DC (for CVM and CVM-4): ± (0, 1% rdg + 0,1% F.S)
  • ± 600 V DC (for SVM): ± (0, 1% rdg + 0,1% F.S)
  • Temperature:

8.11 In x 7.08 in 2.51 in CVM: 66 mm x 28 mm x 139 mm

2.6 In x 1.1 in x 5.5 in CVM-4: 66 mm x 28 mm x 139 mm 2.6 In x 1.1 in x 5.5 in SVM: 66 mm x 28 mm x 139 mm 2.6 In x 1.1 in x 5.5 in SCM: 66 mm x 28 mm x 139 mm 2.6 In x 1.1 in x 5.5 in

Weight: BVS-CU: 0, 78 kg / 1.7 lbs. CVM: 0, 14 kg / 0.3 lbs. CVM-4: 0, 14 kg / 0.3 lbs. SVM: 0, 18 kg / 0.4 lbs. SCM: 0, 18 kg / 0.4 lbs.

  • 20 °C - +80 °C / -4 °F - +176 °F

Warranty

BVS-CU and CVM/CVM-4 communication

  • RS485 serial communication
  •  3 years

Applicable Standards

  •  Pollution degree: 2

Communication with PC

  • USB
  • Bluetooth
  •  Insulation category: I
  •  Safety: EN 61010-1, LVD 2014/35/EU
  • IEC 61010-1 (International standard)
  • UL 61010-1

Memory

  • Internal SD Card: 2 GB SD

CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment 1

Electromagnetic Compatibility (EMC)

Environment conditions

  • Temperature:
  • CE conformity: EMC standard EN 61326-1:2013 EMC directive 2014/30/EU
  • 40 °C to +85 °C /-40 °F to +185 °F

All specifications herein are valid at cell temperature of + 25 °C and recommended accessories. Specifications are subject to change without notice.

*Applies only to BVS

Ordering Info:

InstrumentArticle No
Battery Voltage Supervisor Control UnitBVS-CUNN-000
Battery Voltage Supervisor BVS-4 Control UnitBVS4-CUNN-00
Included accessoriesArticle No
Mains power cable, DV-B Win software including USB cable,
Recommended accessoriesArticle No
Cell Voltage modules CVM * (for BVS)BVS-CVMCN-00
Cell Voltage module CVM-4* (for BVS-4)BVS-CVM4N-00
Voltage sense cables 2 x 0,25 m 1mm2 with banana plugs + alligator clips (for BVS)**S-025-01BPAC
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with banana plugs + dolphin clips (for BVS-4) **S230-00NN-DC
Communication cable for CVM-C connection 1 x 0,25 m (for BVS)C1-0025-RJRJ
Communication cable for CVM connection 1 x 0,75 m (for BVS-4)C1-0075-RJRJ
Communication cable for CVM connection 1 x 2 mC1-2000-RJRJ
Temperature sensor for ambient temperature measurement 1,5 mTP-2015-NTC1
Cable bagCABLE-BAG-00
Plastic transport case for BVS Control Unit and CVMPLST-CAS-BV1
Optional accessoriesArticle No
String Voltage moduleBVS-SVM00-00
String Current moduleBVS-SCM00-00
Voltage sense cables 2 x 0,25 m 1mm2 with banana plugs + dolphin clips (for BVS)S-025-01BPDC
Voltage sense cables 2 x 0,5 m 1mm2 with banana plugs + alligator clips (for BVS)S-005-01BPAC
Voltage sense cables 2 x 0,5 m 1mm2 with banana plugs + dolphin clips (for BVS)S-005-01BPDC
Voltage sense cables 2 x 0,5 m 1mm2 with banana plugs + alligator clips (for BVS)S-005-01BPAC
Voltage sense cables 2 x 0,25 m 1mm2 with banana plugs (for BVS)S-025-01BPBP
Voltage sense cables 2 x 0,5 m 1mm2 with banana plugs (for BVS)S-005-01BPBP
Voltage sense cable set 2 x 1 m, 2 x 0,75 m and 1 x 0,5 m for CVM-4 with banana plugs + alligator clips (for BVS-4)S221-00NN-AC
Voltage sense cable set 2 x 1 m, 2 x 0,75 m and 1 x 0,5 m for CVM-4 with banana plugs + dolphin clips (for BVS-4)S221-00NN-DC
Voltage sense cable set 2 x 1 m, 2 x 0,75 m and 1 x 0,5 m for CVM-4 with temperature sensor and banana plugs + dolphin clips (for BVS-4)S221-00TS-DC
Voltage sense cable set 2 x 1 m, 2 x 0,75 m and 1 x 0,5 m for CVM-4 with temperature sensor and banana plugs + alligator clips (for BVS-4)S221-00TS-AC
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with banana plugs + alligator clips (for BVS-4)S230-00NN-AC
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with temperature sensor and banana plugs + alligator clips (for BVS-4)S230-00TS-AC
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with temperature sensor and banana plugs + dolphin clips (for BVS-4)S230-00TS-DC
Communication cable for CVM connection 1 x 1 mC1-1000-RJRJ
Communication cable for CVM connection 1 x 0,25 mC1-0025-RJRJ
Communication cable for CVM connection 1 x 0,5 mC1-0005-RJRJ
Sense cables 2 x 5 m with banana plugs + dolphin clipS2-05-00BPDC
Current clamp 30/300 A with internal battery supply and extension 5 mCACL-0300-08
Plastic transport case for CVMPLST-CAS-BV2
Cable plastic case - small sizeCABLE-CAS-01
Cable plastic case - medium size –CABLE-CAS-02
Cable plastic case – large sizeCABLE-CAS-03
Alligator clip (red)ALIG-CLP-R00
Alligator clip (black)ALIG-CLP-B00
Dolphin clip (red)DOLP-CLP-R00
Dolphin clip (black)DOLP-CLP-B00
Rechargeable NiMH battery 8,4 V 300 mAh for current clampsRCGB-30084-0
Battery charger 2 x 9 V for NiMH/NiCd batteriesBATCH-2X9V-0
  • * Number of CVM/CVM-4 may vary depending on application
  • ** Different cable lengths available upon request
  • ***Different types of temperature sensors available upon request

Order Examples (BVS):

BVS for 24 cells supervision:

Instrument with Included AccessoriesQuantityArticle No
Battery Voltage Supervisor Control UnitBVS-CUNN-000
- Mains power cable1 set
- USB with DV-B Win PC software1 set
- USB cable
Recommended Accessories
Cell Voltage module CVM24 pcsBVS-CVMCN-00
Voltage sense cables 2 x 0,25 m 1mm2 with banana plugs + alligator clips24 setS230-00NN-DC
Communication cable for CVM-C connection 1 x 0,25 m23 pcsC1-0025-RJRJ
Communication cable for CVM connection 1 x 2 m1 pcC1-2000-RJRJ
Temperature sensor with cable 1,5 m for temperature measurement1 pcTP-2015-NTC1
Cable bag1 pcCABLE-BAG-00
Plastic transport case for BVS Control Unit and CVM1 pcPLST-CAS-BV1

BVS for 120 cells supervision:

Instrument with Included AccessoriesQuantityArticle No
Battery Voltage Supervisor Control UnitBVS-CUNN-000
- Mains power cable1 set
- USB with DV-B Win PC software1 set
- USB cable
Recommended Accessories
Cell Voltage module CVM120 pcsBVS-CVMCN-00
Voltage sense cables 2 x 0,25 m 1mm2 with banana plugs + alligator clips120 setS230-00NN-DC
Communication cable for CVM-C connection 1 x 0,25 m119 pcsC1-0025-RJRJ
Communication cable for CVM connection 1 x 2 m1 pcC1-2000-RJRJ
Temperature sensor with cable 1,5 m for temperature measurement1 pcTP-2015-NTC1
Cable bag1 pcCABLE-BAG-00
Plastic transport case for BVS Control Unit and CVM1 pcPLST-CAS-BV1
Plastic transport case for CVM2 pcPLST-CAS-BV2

Order Examples (BVS-4):

BVS-4 for 24 cells supervision:

Instrument with Included AccessoriesQuantityArticle No
Battery Voltage Supervisor BVS-4 Control UnitBVS4-CUNN-00
- Mains power cable1 set
- USB with DV-B Win PC software1 set
- USB cable
Recommended Accessories
Cell Voltage module CVM-46 pcsBVS-CVM4N-00
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with banana plugs +dolphin clips6 setS230-00NN-DC
Communication cable for CVM connection 1 x 0,75 m5 pcsC1-0075-RJRJ
Communication cable for CVM connection 1 x 2 m1 pcC1-2000-RJRJ
Temperature sensor with cable 1,5 m for temperature measurement1 pcTP-2015-NTC0
Cable bag1 pcCABLE-BAG-00
Plastic transport case for BVS Control Unit and CVM1 pcPLST-CAS-BV1

BVS-4 for 120 cells supervision:

Instrument with Included AccessoriesQuantityArticle No
Battery Voltage Supervisor BVS-4 Control UnitBVS4-CUNN-00
- Mains power cable1 set
- USB with DV-B Win PC software1 set
- USB cable
Recommended Accessories
Cell Voltage module CVM-430 pcsBVS-CVM4N-00
Voltage sense cable set 2 x 0,75 m and 3 x 0,5 m for CVM-4 with banana plugs +dolphin clips30 setS230-00NN-DC
Communication cable for CVM connection 1 x 0,75 m29 pcsC1-0075-RJRJ
Communication cable for CVM connection 1 x 2 m1 pcC1-2000-RJRJ
Temperature sensor with cable 1,5 m for temperature measurement1 pcTP-2015-NTC0
Cable bag2 pcCABLE-BAG-00
Plastic transport case for BVS Control Unit and CVM1 pcPLST-CAS-BV1

IBEKO Power AB Stockholmsvägen 18 181 50 Lidingö, Sweden

Contact Phone: +46 70 0925 000 E-mail: sales@dv-power.com

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote