Skip to content

Accessible version

AMPERIS HPS-HV DC Fast Charging Stations

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 5 pages · 170 KB)

Up to 60 kW and 800 V DC per parallelable unit

Battery charging and maintenance equipment

Image: Grey floor-standing metal cabinet with a small display, red emergency stop button and front ventilation grille.

High-voltage DC fast charging stations

DC fast charging for lithium-ion and any other battery chemistry, indoors or outdoors.

Product overview

Image: Indoor cabinet version

Fast charging without borders

The HPS-HV family of DC fast charging stations is optimised for lithium-ion batteries and supports batteries of any type, chemistry, voltage and size. Third-generation IGBT-Hybrid power conversion combines performance, energy efficiency and robustness, with standard powers from 10 to 60 kW, outputs of 12-650 V DC (250-800 V DC in the H models) and a parallelable design that grows with the fleet.

Efficiency that pays for itself

Maximum efficiency exceeds 97 % with a power factor above 0.99, input current distortion below 15 % and output ripple under 8 % peak-to-peak; standby consumption stays below 10 W. The smart LCD interface manages charging priorities, timing, energy limiting and peak shaving.

Main features

  • Multi-vehicle operation with automatic battery/EV recognition.
  • Preprogrammed standard charging curves for quick set-up.
  • Integrated datalogger for troubleshooting and optimisation.
  • Automatic compensation of the DC cable voltage drop.
  • CANBUS interface for BMS with multiple protocols and data rates.
  • Indoor and outdoor versions; worldwide supply voltages and certifications.

Applications and options

Applications

  • Fleets of industrial, commercial and passenger electric vehicles.
  • Forklifts and airport ground support equipment (optional GSE version).
  • Cold rooms and mining equipment (optional CME version).
  • Fast and opportunity charging in 24/7 operations.

Options

The stations accept a stacklight for charger and battery status, an auto-watering system, an air pump for electrolyte recirculation, a charging stand with cable management and integration with wireless battery identification modules.

HPS-HV — TECHNICAL SPECIFICATIONS

COMMON SPECIFICATIONS

AC input voltage3×400/415/440 V AC (others on request)
Output voltage range (standard)12-650 V DC
Output voltage range (extended)250-800 V DC
Safety, EMC and environmental standardsIEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS

STANDARD MODELS (12-650 V DC)

ModelHPS.M12HPS.M20HPS.M24HPS.M30HPS.M36HPS.M50HPS.M60H
Output power12 kW20 kW24 kW30 kW36 kW50 kW60 kW
Max DC current150 A150 A150 A150 A150 A150 A150 A
AC input current @ 400 V AC20 A32 A40 A50 A60 A83 A100 A

EUROPE, ASIA, OCEANIA AND SOUTH AMERICA (EXTENDED DC RANGE)

ModelHPS.H50HPS.H60
Output power50 kW60 kW
Max DC current100 A100 A
AC input current @ 400 V AC83 A100 A

Models for Europe, Asia, Oceania and South America (3×400/415/440 V AC). Other AC input voltages, including North American versions, available on request. Parallelable design.

HPS-HV — TECHNICAL SPECIFICATIONS

DIMENSIONS — INDOOR VERSION (UP TO 36 kW)

Width 717 mm
Depth 559 mm
Height 1210 mm

DIMENSIONS — OUTDOOR VERSION (UP TO 60 kW)

DimensionTMTQ
Width887 mm870 mm
Depth716 mm689 mm
Height1318 mm1611 mm

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote