AMPERIS XMV Universal Battery Charger and Conditioner

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 8 pages · 185 KB)

Desulphation, testing and formation from single cells to 96 V packs

Battery charging and maintenance equipment

Image: Two battery chargers: a large black cabinet unit with control panel and a smaller wheeled unit with cooling fins.

Universal battery charger and conditioner

Programmable multi-voltage charging for the whole life cycle of lead-acid and lithium batteries.

Product overview

Image: Portable and stationary versions

One charger for the whole workshop

The XMV is a programmable multi-voltage charger and conditioner for service centres, laboratories and battery regeneration workshops. It manages the entire battery life cycle — first formation charge, validation tests and desulphation of degraded units — on any chemistry: vented, AGM and gel lead-acid or LFP, NMC and LTO lithium, from single 2 V cells to packs of 96/120 V nominal.

Recovery with laboratory precision

Field-tested desulphation algorithms break down internal resistance and restore lost capacity in sulphated batteries, while a regulated, filtered output with minimal ripple suits lithium cell balancing and BMS recalibration. Full digital control adapts the curve to the battery response, and integrated diagnostics detect short-circuited cells before treatment.

Main features

  • Output of 0-150 V DC with 3 to 36 kW and up to 600 A.
  • Single-phase (110-230 V) or three-phase (400-600 V) supply.
  • Automatic cycling of charge-rest or charge-discharge with an XD unit.
  • Portable versions on wheels or stationary for charging rooms.
  • Power factor above 0.98 and standby consumption below 10 W.
  • Protection against overload, overtemperature and reverse polarity.

Applications and configurations

Applications

  • Recovery and desulphation of lead-acid batteries.
  • Balancing and testing of lithium packs during test cycles.
  • Formation charges and validation tests in laboratories.
  • Battery Cycler configuration paired with the XD discharger (XD-Combo).

Built for the workshop

The cabinet withstands acid vapours and workshop temperatures, with the control panel oriented towards the operator in the portable versions; stationary units up to 36 kW handle large-capacity packs in charging rooms and intensive test laboratories.

USA AND CANADA

ModelXMV.12.USXMV.12.NAXMV.15.NAXMV.20.NAXMV.24.NAXMV.36.NA
Maximum output power12 kW12 kW15 kW20 kW24 kW36 kW
DC output voltage range2-150 V DC2-150 V DC2-150 V DC2-150 V DC2-150 V DC2-150 V DC
Max DC current @ 70/130/150 V DC200/120/100 A200/120/100 A250/150/120 A320/190/150 A400/230/200 A600/360/280 A
ConnectorSingleSingleSingleSingle or dualSingle or dualSingle or dual
AC input voltages3×208/240/480 V AC3×480/600 V AC3×480/600 V AC3×480/600 V AC3×480/600 V AC3×480/600 V AC
AC input current39 A @ 208 V AC / 17 A @ 480 V AC17 A @ 480 V AC / 14 A @ 600 V AC20 A @ 480 V AC / 17 A @ 600 V AC27 A @ 480 V AC / 22 A @ 600 V AC34 A @ 480 V AC / 27 A @ 600 V AC50 A @ 480 V AC / 40 A @ 600 V AC
Power factor>0.98>0.98>0.98>0.99>0.99>0.99
Idle power<10 W<10 W<10 W<10 W<10 W<10 W
Cabinet typeTLTLTLTPTPTP

Safety: UL 1564 4th Edition 2015 “Industrial Battery Chargers”; CSA C22.2 No. 107.2-01 R2016 “Battery Chargers”. Standards: NRTL certification QPS, file LR1649.

EUROPE, ASIA, OCEANIA AND SOUTH AMERICA

ModelXMV.12.EUXMV.15.EUXMV.20.EUXMV.24.EUXMV.30.EUXMV.36.EU
Maximum output power12 kW15 kW20 kW20 kW30 kW40 kW
DC output voltage range2-150 V DC2-150 V DC2-150 V DC2-150 V DC2-150 V DC2-150 V DC
Max DC current @ 70/130/150 V DC200/120/100 A250/150/120 A320/190/150 A400/230/200 A500/300/240 A600/360/280 A
ConnectorSingleSingleSingleSingleSingle or dualSingle or dual
AC input voltages3×400 V AC3×400 V AC3×400 V AC3×400 V AC3×400 V AC3×400 V AC
AC input current20 A25 A32 A41 A48 A63 A
Power factor>0.98>0.98>0.99>0.99>0.99>0.99
Idle power<10 W<10 W<10 W<10 W<10 W<10 W
Cabinet typeTLTLTPTPTPTP

Safety, EMC and environmental: IEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS.

EUROPE, ASIA, OCEANIA AND SOUTH AMERICA (EXTENDED DC RANGE)

ModelXMV.E.20.EUXMV.E.24.EUXMV.E.30.EUXMV.E.36.EU
Maximum output power20 kW20 kW30 kW40 kW
DC output voltage range2-180 V DC2-180 V DC2-180 V DC2-180 V DC
Max DC current @ 70/130/150/180 V DC220/190/150/80220/220/200/100220/220/220/125220/220/220/150
ConnectorSingleSingleSingle or dualSingle or dual
AC input voltages3×400 V AC3×400 V AC3×400 V AC3×400 V AC
AC input current32 A41 A48 A63 A
Power factor>0.99>0.99>0.99>0.99
Idle power<10 W<10 W<10 W<10 W
Cabinet typeTPTPTPTP

Safety, EMC and environmental: IEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS.

PORTABLE UNITS (EUROPE AND USA AC INPUT)

ModelXMV.M.50.EUXMV.M.80.EUXMV.M.50.USXMV-2M.160.EU
Maximum output power3 kW3 kW3 kW6 kW
DC output voltage range2-120 V DC2-70 V DC2-120 V DC2-70 V DC
Max DC current @ 24/48/80 V DC50/50/2580/50/X50/50/25160/100/X
ConnectorSingleSingleSingleSingle
AC input voltages1×230 V AC1×230 V AC1×208/240 V AC1×208/240 V AC
AC input current15 A15 A20 A32 A
Power factor>0.9>0.9>0.9>0.9
Idle power<10 W<10 W<10 W<10 W
Cabinet typeTDTDTDTL

Safety: EU models per IEC 60335-1:2010, EN IEC 61000-6-2:2019, EN 61000-6-4:2007, EN 61000-6-4:2007/A1:2011, 2011/65/EU RoHS; US model per UL 1564 4th Ed. 2015 and CSA C22.2 No. 107.2-01 R2016 (NRTL QPS, file LR1649).

DIMENSIONS — STANDARD CABINETS (IP21)

CabinetTDTLTP
Width335 mm538 mm717 mm
Depth690 mm487 mm559 mm
Height530 (756 with raised keyboard) mm926 mm1210 mm

DIMENSIONS — OUTDOOR CABINETS (IP54)

CabinetTNTM
Width659 mm887 mm
Depth612 mm716 mm
Height1019 mm1318 mm

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote