BAC SERIES Battery Charger

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 217 KB)

Image: DV Power battery charger unit with handle, LCD display, keypad, temperature input, interface and output terminals with voltage sense.
  •  Lightweight – only 10 kg / 22 Ibs
  •  Instrument max power – up to 2,7 kW
  •  Voltage range up to 300 V DC
  •  Current range up to 50 A DC
  •  Measurement resolution – current 0,1 A, voltage 0,1 V
  •  Two charging modes available:

IU - constant current + constant voltage,

UU - constant voltage + constant voltage, with current limit

  •  Adjustable alarm and shutdown parameters for preventing excessive charge

Powerful and Portable Battery Charger Description

Following a power outage, various power engineering objects such as power plants should be kept operating on batteries. It is necessary batteries to be charged in order to compensate its energy loss and keep their voltage within the predefined limits. BAC series devices are a portable battery charger used for charging LeadAcid, Ni-Cd and Li-ion batteries. BAC series devices are intended to support the main charger in order to charge battery much faster or to quickly recharge a battery following a discharge test. Using two charging modes it provides the possibility of maintaining and recharging the batteries either with a constant current or a constant voltage.

BAC Series contains two models, depending of maximum charging current by different voltage levels:

  • BAC25A model can generate currents up to 25 A, with a maximum output voltage of 300 V (the maximal current is 10 A at 300V)
  • BAC50L model can generate currents up to 50 A (for voltages up to 50 V), with a maximum output voltage of 60 V (the maximal current is 30 A at 60 V)

In addition, BAC Series devices are equipped with thermal, overcurrent, and over-voltage or under voltage protection.

Provided display enables users to read all relevant information during a charging process and to adjust the charging current, charging time, etc.

MainsMaximum C DCCurrent (A C)Boost vo DColtage (V C)Float vo DColtage (V C)
Mains Voltage Vo (Voltage V DC)DCC)DC Lead-C)DC Lead-C)
(V AC) (VV DC)BAC25ABAC50LLead- AcidNi-CdLead- AcidNi-Cd
1,2-50-1,5-1,4
2-502,45-2,25-
6-5077,56,757
12255014151314
230/11524255029302728
482530 (230V) 20 (115V)57605456
6025-72756870
1110/12020 (230 V) 10 (115 V)-133/145140/150125/135130/140
2220/24010 (230 V) 5 (115 V)-263/290275/300148/270250/280

Table 1. Maximum Charging Currents for charging Lead-Acid and Ni-CD batteries

Mains Voltage (V AC) Vo (Voltage V DC)Maximum C DC BAC25ACurrent (A C) BAC50LBoost voltage (V DC)Float voltage (V DC)
3,6-504,24
7,2-508,48
230/115 114,4255016,816
230/115 225,2255029,428
39,62550 (230V) 25 (115V)46.244
550,42530 (230V) 20 (115V)58,856

Table 2. Maximum Charging Currents for charging Li-ion batteries

Benefits and Features

  • 1. Display - Values of output voltage, current and other working status information are displayed on the LCD screen.
  • 2. Keyboard - used for controlling and operating the instrument.
  • 3. Status indicating LED diodes
  • 4. PT100 probe connector for ambient temperature measurement.
  • 5. USB PC Interface.
  • 6. Overvoltage alarm terminal - used for triggering external alarm.
  • 7. Undervoltage alarm terminal - used for triggering external alarm.
  • 8. Current and voltage sense terminals - connecting the current and voltage sense cables.
Image: Front panel of the DV Power battery charger unit with numbered callouts: display, indicators, keys, temperature input, interface, over- and under-voltage indicators, voltage sense and output terminals.

Application example

Typical application is charging batteries that serve as a backup power supply in:

  • Power plants
  • Generator excitation systems
  • Substations
  • Protection and control systems
  • UPS battery strings

The BAC series devices is connected to a test battery using the current cables. The voltage sense cables may be used optionally. Next step is to set the current and the voltage alarm levels. After starting the charging process BAC series devices keeps the current or voltage level constant depending on the selected charging mode. When applying the IU charging mode, the battery is charged with a constant current. The voltage increases to a level close to the final voltage (boost voltage), the device switches to a constant voltage (float voltage) mode and the current begins to decrease. Cut off occurs when a predetermined minimum current value, which indicates a full charge, has been reached. When opting for the UU charging mode the battery will be charged under a constant voltage. If the battery current becomes larger than the defined current limit, the charger will switch into a constant current mode and continue charging with constant current that is equal to specified current limit.

Image: Connection diagram of a string of eight batteries linked to a DV Power battery test unit through current cables and voltage sense leads.

Otherwise, the charger keeps charging under the selected constant voltage, the current will decrease over time until it reaches a predetermined minimum value. At this point of time the charger will switch to a float charge stage and decrease to a selected float voltag

BAC Series - models

BAC25A

Image: Compact battery charger unit with LCD display, keys, output terminals and carrying handle.
  • Applicable to 10 – 300 V DC battery voltages
  • Weight – 10 kg (22 lbs)
  • Instrument max power – up to 2,7 kW
  • Current range – up to 25 A

BAC50L

Image: Compact battery charger unit with LCD display, keys, output terminals and carrying handle.
  • Applicable to 1 V – 60 V DC battery voltages
  • Weight – 10 kg (22 lbs)
  • Instrument max power – up to 2,5 kW
  • Current range – up to 50 A

Technical Data

Mains Power Supply

  • Connection according to IEC/EN60320-1; C320

Electromagnetic Compatibility (EMC)

  • Directive 2014/30/EU (CE conform) Applicable standard : EN 61326-1
  • Voltage 90 V – 264 V AC, 50 / 60 Hz,
  • single-phase
  • Power consumption: up to 3 300 VA

Dimensions and Weight

  • Dimensions:

(D x W x H) without handle:

Output data

  • Max. Output current: 25 A DC (BAC25A) 50 A DC (BAC50L)
  • Voltage: 10-300 V DC (BAC25A) 1-60 V DC (BAC50L)
  • Typical voltage accuracy: ± (0,25 % rdg + 0,25 % FS)

407 mm x 198 mm x 275 mm

  • 16 in x 7.8 in x 10.8 in
  • Weight:

10 kg / 22 lbs.

Warranty

  • Three years

Environment conditions

  • Temperature -10 °C to +45 °C / 14 °F to +113 °F
  • Maximum relative humidity 95 % for temperatures up to 31 °C, decreasing linearly to 40 % relative humidity at 45 °C

Safety Standards

  • Safety
  • Low Voltage Directive: Directive 2014/35/EU (CE conform) Applicable standards, for a class I instrument, pollution degree 2, Installation category II: IEC EN 61010-1
  • CAN/CSA-C22.2 No. 61010-1
  • Pollution degree 2

All specifications herein are valid at ambient temperature of + 25 °C/77° F and recommended accessories. Specifications are subject to change without notice.

Image: Red and black test leads with red crocodile clips.
Image: Pair of black test leads with red and black crocodile clips and angled plugs.
Image: Test instrument housed in an open aluminium flight case with cables stored in the lid.

Voltage sense cables

Current cables

Transport case

Order Info

InstrumentArticle No
Battery charger BAC25ABAC25A-NN-01
Battery charger BAC50LBAC50L-NN-01
Included AccessoriesArticle No
Mains power cableMPCxxA-xx-00
Transport caseHARD-CASE-ME
Ground (PE) cableCABLE-GND-00
RecommendedArticle No
Current cables 2 x 3 m 6 mm2 (9.8 ft., 9 AWG) with alligator clamps (A2) isolated (for BAC25A)C2-03-06BMA2
Current cables 2 x 3 m 10 mm2 (9.8 ft., 8 AWG) with alligator clamps (A3) isolated (for BAC50L)C2-03-10BMA3
OptionalArticle No
Current cables 2 x 5 m 6 mm2 (16.4 ft., 9 AWG) with alligator clamps (A2) isolated (for BAC25A)C2-05-06BMA2
Current cables 2 x 10 m 6 mm2 (32.8 ft., 9 AWG) with alligator clamps (A2) isolated (for BAC25A)C2-10-06BMA2
Current cables 2 x 15 m 6 mm2 (49.2 ft., 9 AWG) with alligator clamps (A2) isolated (for BAC25A)C2-15-06BMA2
Current cables 2 x 20 m 6 mm2 (65.6 ft., 9 AWG) with alligator clamps (A2) isolated (for BAC25A)C2-20-06BMA2
Current cables 2 x 5 m 10 mm2 (16.4 ft., 8 AWG) with alligator clamps (A3) isolated (for BAC50L)C2-05-10BMA3
Current cables 2 x 10 m 10 mm2 (32.8 ft., 8 AWG) with alligator clamps (A3) isolated (for BAC50L)C2-10-10BMA3
Current cables 2 x 15 m 10 mm2 (49.2 ft., 8 AWG) with alligator clamps (A3) isolated (for BAC50L)C2-15-10BMA3
Current cables 2 x 20 m 10 mm2 (65.6 ft., 8 AWG) with alligator clamps (A3) isolated (for BAC50L)C2-20-10BMA3
Sense cables 2 x 3 m 1,5 mm2 (9.8 ft., 13 AWG) with banana plugs + dolphin clipS2-03-15BPDC
Sense cables 2 x 5 m 1,5 mm2 (16.4 ft., 13 AWG) with banana plugs + dolphin clipS2-05-15BPDC
Sense cables 2 x 10 m 1,5 mm2 (32.8 ft., 13 AWG) with banana plugs + dolphin clipS2-10-15BPDC
Sense cables 2 x 15 m 1,5 mm2 (49.2 ft., 13 AWG) with banana plugs + dolphin clipS2-15-15BPDC
Sense cables 2 x 20 m 1,5 mm2 (65.6 ft., 13 AWG) with banana plugs + dolphin clipS2-20-15BPDC
Cable for external alarm 2 x 5 m (16.4 ft.)CA-EXABAC-05
Extension cable for external alarm 2 x 5 m (16.4 ft.,)E1-EXABAC-05
PT100 temperature indicatorTI-000-PT100
Device bagDEVIC-BAG-00
Cable bagCABLE-BAG-00

IBEKO Power AB Stockholmsvägen 18 181 50 Lidingö, Sweden

Contact Phone: +46 70 0925 000 E-mail: sales@dv-power.com

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote