RAPIDOX 5100 MULTIGAS ANALYZER
The Rapidox 5100 Multigas Analyser is a high specification portable instrument designed for the analysis, control and monitoring of gas in a wide range of applications including; biogas, syngas, anaerobic digestion and fermentation processes.
Amperis Products, S.L. C/Barbeito María, 14 27003, Lugo, Galicia, España
Contact: Phone : +34 982 209 920
Up to six gases are simultaneously measured using a range of high precision gas sensors; each sensor is specially designed and calibrated to avoid cross interference effects with background process gas, Safety is ensured by the inclusion of flashback arrestors in the gas measuring circuit where required.
Measurable gases include oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), moisture (H2O), hydrogen (H2), hydrogen sulphide (H2S), nitric oxide (NO), nitrogen dioxide (NO2), nitrous oxide (N2O), sulphur dioxide (SO2), chlorine (Cl2), methane (CH4) and ethylene (C2H4).
When configured for applications where the gases contain energy (e.g. Biogas, Syngas) the calorific value of the gas sample is determined using thermodynamic calculations and simultaneously logged and displayed on-screen.
An optional pump enables two modes of operation. For samples that are taken from a gas source at atmospheric pressure or below, the pump is activated to draw a sample through the analyser. Alternatively, the pump can be deactivated when sampling from a source at a greater atmospheric pressure, allowing the gas to flow through the analyser. Gas flow is regulated manually via a rotary knob on the fascia and displayed electronically on the screen.
Please contact Cambridge Sensotec for further information or to discuss your requirements.
| Though highly configurable | • Bespoke sensor combination | • Continuous data logging downloaded |
|---|---|---|
| to suit individual customer | • 7" full-colour touchscreen | via USB. |
| requirements, the Rapidox 5100 | • Lithium battery provides 8 | • Multi-language |
| range possesses a number of | hours of operation | • Charges on worldwide |
| standard features to enhance | • Heavy duty IP66 case | mains voltage |
| functionality. | • Password protection | • Integrated thermal printer |
Applications
Biogas
Combustion
Emissions
Gas
Research & Development
Syngas
Accesories
- 1)Calibration Kit
- 2)Calibration Service
- 3)Gas Recovery Bag
- 4)Sample Probe
- 5)Sample Probe Filters
- 6)Collapsible Sample Probe
| SPECIFICATION | |
|---|---|
| Ambient Operating Temperature | -10°C to 40°C |
| Warm-up Time | 3-4 minutes at 20o C |
| Measurement Time | Approximately 2-4 minutes (dependant on sensor configuration) |
| Battery Life | In excess of 8 hours (up to 500 cycles). 4-6 hour charge |
| Voltage (Charging) | 90-260VAC, 50/60Hz |
| Sample Connections | 4mm ID/6mm OD Rectus style, closed coupled fittings |
| Data Output | Excel compatible data via USB memory stick |
| Data Storage | 4GB internal data storage allowing for approximately 1 year of continuous monitoring |
| Optional Pump | 0-1 litres per minute |
| Calibration | Zero and span calibration with two user selectable gas compositions |
| Display | 7" (180mm) full-colour LCD with touchscreen operation |
| Printer | Thermal printer allows output of results on demand |
| Analyser Dimensions | 180mm(H) x 480mm(W) x 360mm(D) |
| Weight | 7kg |
Rapidox 5100 Sensor Matrix
| Gas | O2 | CO2 | CH4 CH4 | H2O | CO | CO | CO (H2 resist) | Cl2 | NO | NO2 | C2H4 | O3 | H2S | He/H2 | NH3 | SO2 SO2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sensor Type | EC-E | IR | IR LTD | CAP | IR | EC | EC | ECE | EC | EC | IR | EC | EC | TCD | EC | EC IR |
| ife span (mth) | 60 | >60 | >60 >60 | >36 | >60 | 24 | 24 | 12 | 12 | 12 | >60 | 12 | 24 | >60 | 24 | 24 >60 |
| Cal. (mth) | 12 | 12 | 12 12 | 12 | 12 | 12 | 12 | 6 | 6 | 6 | 12 | 6 | 12 | 12 | 12 | 12 12 |
| 0-100% | ||||||||||||||||
| 0-80% | ||||||||||||||||
| 0-60% | ||||||||||||||||
| 0-50% | ||||||||||||||||
| 0-30% | ||||||||||||||||
| 0-20% | ||||||||||||||||
| 0-10% | ||||||||||||||||
| 0-5% | ||||||||||||||||
| 0-3% | ||||||||||||||||
| 0-2% | ||||||||||||||||
| 0-1% | ||||||||||||||||
| 0-5,000ppm | ||||||||||||||||
| 0-3,000ppm | ||||||||||||||||
| 0-2,000ppm | ||||||||||||||||
| 0-1,000ppm | ||||||||||||||||
| 0-500ppm | ||||||||||||||||
| 0-250ppm | ||||||||||||||||
| 0-200ppm | ||||||||||||||||
| 0-100ppm | ||||||||||||||||
| 0-60ppm | ||||||||||||||||
| 0-20ppm | ||||||||||||||||
| 0-10ppm | ||||||||||||||||
| -65oC to+20oC | ||||||||||||||||
| -100oC | ||||||||||||||||
| 0 to 5 bar | ||||||||||||||||
| 0 to 10 bar | ||||||||||||||||
| -1 to 0 bar |