Skip to content

Accessible version

RAPIDOX 7100

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 5 pages · 233 KB)

RAPIDOX 7100 MULTIGAS ANALYZER

Image: Rapidox 7100 rack-mounted gas analyser with a colour display listing CH4, CO2, CO, H2 and energy, and a red power switch.

The Rapidox 7100 Multigas Analyser is a high specification instrument designed for the analysis, control and monitoring of process gas in a wide range of industries.

Amperis Products, S.L. C/Barbeito María, 14 27003, Lugo, Galicia, España

Contact: Phone : +34 982 209 920

Up to six gases are simultaneously measured using a range of high precision gas sensors; each sensor is specifically designed and calibrated to avoid any cross-interference effects with the background process gas. Measurable gases include oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), moisture (H2O), hydrogen (H2), hydrogen sulphide (H2S), nitric oxide (NO), nitrogen dioxide (NO2), nitrous oxide (N2O), sulphur dioxide (SO2), chlorine (Cl2), methane (CH4), ethylene (C2H4) and many more. View the sensor matrix for more information.

When configured for applications where the gases contain energy (e.g. Biogas, Syngas) the calorific value of the gas sample is determined using thermodynamic calculations and simultaneously logged and displayed onscreen. Data is downloadable via USB memory stick, and 4GB of internal data storage allowance allows for approximately one year of continuous monitoring.

An optional pump enables two modes of operation. For samples that are taken from a gas source at atmospheric pressure or below, the pump is activated to draw a sample through the analyser. Alternatively, the pump can be deactivated when sampling from a source at a greater atmospheric pressure, allowing the gas to flow through the analyser. Gas flow is regulated manually via a rotary knob on the fascia and displayed electronically on the screen.

Available in both a 19" rack mountable case or a benchtop version.

Though highly configurable • Bespoke sensor combination • Multi-language to suit individual customer • 7" full-colour touchscreen • Six programmable alarms requirements, the Rapidox 7100 • 19" rack mountable enclosure or • Operates on worldwide mains voltage range possesses a number of benchtop • Password protection standard features to enhance • Continuous data logging functionality.

Applications

Image: Biogas plant with a domed storage tank in a green meadow surrounded by trees.
Image: Application icons: biogas, chemicals, combustion, food, gas, glove boxes, gas blanketing and manufacturing.

Medical Metal Heat Treatment Research & Development Syngas

Accesories

Image: Six numbered accessories: 1 calibration gas cylinders in a carrying case, 2 rack-mounted unit, 3 orange portable unit, 4 portable printer, 5 gas sampling panel with valves, 6 filter and fitting.
  • 1)Calibration Kit
  • 2)Multiplex Sampling System
  • 3)Gas Recovery Bag
  • 4)Thermal Printer
  • 5)Calibration Service
  • 6)Gas Filters
SPECIFICATION
Voltage90-260 VAC, 50/60Hz
Analyzer DimensionsRack Mount: 132mm(H) x 482mm(W) x 365mm(D) Benchtop: 180mm (H) x 570mm (W) x 345mm (D)
WeightRack Mount: 6.5kg Benchtop: 6.5kg
Warm-up time3-4 minutes at 20°C
Normal Operating ConditionsTemperature 0°C to 40°C Humidity 10 - 90% RH Pressure 900 to 1100 mbar absolute
Display7" (180mm) full-colour LCD with touchscreen operation; resolution 0.01ppm or 0.01%
Sample Connections6mm OD or 1/4" Swagelok fittings. Rear positioning
Voltage Outputs0-10V, user programmable
Current Outputs4-20mA linear, user programmable
Digital OutputsRS232 (RS485 option available) Data streamed on demand. Modbus RTU/Ethernet
Data OutputExcel compatible data via USB memory stick
AlarmsRelay circuits, user programmable
SamplingFixed or continuous sampling modes
CalibrationCalibration by the user using zero and span gases
Image: rapidox 7100 rack-mounted gas analyser: front with screen showing CH4, CO2, CO, H2 and energy readings, and rear panel with terminals, communication ports and mains inlet.
Image: Rapidox 7100 gas analyser, front and rear views: the front screen lists CH4, CO2, CO, H2 and energy readings, and the rear panel shows the mains inlet, fan, terminal blocks and communication ports.

Rapidox 7100 Sensor Matrix

GasO2 O2O2CO2CH4CH4H2OCOCOCO (H2 resist)Cl2NONO2C2H4N2OO3H2SHe/H2NH3 SO2SO2TCSF6
Sensor TypeZr EC-EEC-LIRIRTLDCAPIRECECECECECIRIRECECTCDEC ECIRType KIR
Life span (mth)24 6018>60>60>60>36>602424121212>60>601224>6024 24>60>36>60
Cal. (mth)12 1261212121212121266612126121212 1212N/A12
0-100%
0-80%
0-60%
0-50%
0-30%
0-20%
0-10%
0-5%
0-3%
0-2%
0-1%
0-5,000ppm
0-3,000ppm
0-2,500ppm
0-2,000ppm
0-1,000ppm
0-500ppm
0-250ppm
0-200ppm
0-100ppm
0-60ppm
0-50ppm
0-20ppm
0-10ppm
-65oC to +20 oC
-100oC to +20 oC
0 to 1250 oC

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote