APQM-707 Analyzer

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 4 pages · 164 KB)

APQM-707 Analyzer Electric power quality meter

Power quality analyzer for measurement, analysis, and registration of energy networks in accordance with the standard EN 50160 High measurement category (CAT IV 600V) All parameters are measured in the S class of the IEC 61000-4-30 STANDARD guaranteeing high accuracy of measurements.

Image: Sonel PQM-707 power quality analyser with touchscreen displaying a harmonics bar chart, voltage and current inputs on top and orange protective bumpers.

AMPERIS PRODUCTS S.Lagricultura, 34, 27003 c/ barbeito maría, 14 lugo [spain]27003, Lugo, España

Power Quality Analyzer Amperis APQM-707 is an autonomous meter allowing for versatile measurement, analysis, and registration of energy networks parameters DC and 50/60Hz, including the quality of electric energy in accordance with the European standard EN 50160. Analyzer with 7-inch colour touch screen enables intuitive and ergonomic operation. Thanks to the built-in lithium-ion battery.

The analyzer is directed to a very wide range of users, with particular reference to the maintenance staff and it can be used in virtually all kinds of networks with rated voltage from 54V to 760V directly, or indirectly via transformers.

The device is designed to work with networks:

  • With nominal frequency 50/60Hz,
  • With nominal voltage: 64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 400/690 V,
  • DC network

Supported networks:

  • Single-phase
  • Two-phase with common N conductor
  • Three-phase star connection with and without N conductor
  • Three-phase delta

Contactoo

AMPERIS PRODUCTS S.Lagricultura, 34, Contactoo 27003 c/ barbeito maría, 14 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, España info@amperis.com | www.amperis.com

Software data analysis:

  • General :Measurements, Events and Waveforms
  • Measurements: voltage, frequency, etc.
  • Events: dips, swells, interruptions, etc.
  • Configuration

The software enables different types of diagrams

  • Time diagram
  • Waveforms
  • Harmonics diagram
  • Value/Time diagram

Software data analysis:

Image: Technician with insulating gloves using a stylus on a power analyser touch screen, with leads connected inside an electrical cabinet.
  • PDF, HTML, CSV or TXT files
  • According to EN 50160 standard

AMPERIS PRODUCTS S.Lagricultura, 34, 27003 c/ barbeito maría, 14 lugo [spain]27003, Lugo, España

ParametrParameters of analyz Measurement rangezer: Max. resolutionAccuracy
ParametrMeasurement rangeMax. resolutionAccuracy
Alternating voltage (TRMS)-0,0...760,0V0,01 % Unom±0,5% U nom
Crest FactorVoltage1,00...10,00 ( 1.65 for 690 V voltage)0,01±5%
Crest FactorCurrent1,00...10,00 ( 3,6 Inom)0,01± 5%wm
Alternating current TRMS-depending on clamp*0,01 % Inom±2% m.v. for m.v. 10% Inom ±2% I for m.v. < nom 10% Inom (error does not account for clamps error)
Frequency-40,00...70,00 Hz0,01Hz±0,05 Hz
Active, reactive, apparent and distortion power-depending of configuration (trasformers, clamp)up to for decimal placesdepending on configuration (transformers, clamps)
Active, reactive apparent energy φ-depending of configuration (transformers, clamp)up to for decimal placesas power error
cosφ and power factor (PF) φ-0,00...1,000,01±0,03
Tgφ-0,00...10,000,01depends on active and reactive power error
HarmonicsVoltageas for alternating voltage True RMSas for alternating voltage True RMS±5% m.v. for m.v. 3% Unom ±0,15% U for nom m.v.. < 3% Unom
Currentas for alternating voltage True RMSas for alternating voltage True RMS±5% m.v. for m.v.. 10% Inom ±0,5% I for m.v. < nom 10% Inom
THDVoltage0.0..100.0% (in regards to the rms0,1%±5%
THDCurrentvalue)0,1%±5%
Flicker severity PST, PLT-0,40...10,000,01±10%
Voltage asymmetryVoltage and current0,0...10,0%0,1%±0,15% (absolute error)
Inrush current-depending on clamp*0,01% Inom±4% m.v. for m.v. 10% Inom ±4% I for m.v. < nom 10% Inom (RMS1/2)

*Clamp F-1A, F-2A, F-3A: 0..3000 A (10000 Ap-p) *Clamp C-4A: 0..1000 A (3600 Ap-p)*Clamp C-5A: 0..1000 A (3600 Ap-p)*Clamp C-6A: 0..10 A (36 Ap-p) *Clamp C-7A: 0...100 A (360 Ap-p) Available with other configurations

Contactoo

AMPERIS PRODUCTS S.Lagricultura, 34, Contactoo 27003 c/ barbeito maría, 14 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, España info@amperis.com | www.amperis.com

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote