APQM-711 Analyzer

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 241 KB)

APQM-711 Analyzer Electric power quality meter

High technology equipment for universal measurement Analysis and recording of the parameters of the electric networks of 50/60 Hz The analyzer meets the requirements of EN 50160 and EN 61000-4-30: 2011 class A

Image: Orange Sonel power quality analyser with its leads, connected to a tablet running the analysis software.

The APQM-711 electric power quality analyzer is a high-tech equipment that allows the measurement of the quality of the electric power, the analysis and the registration of the parameters of the electric networks of 50/60 Hz and in accordance with European standard EN 50160 on the specific operating conditions of the electro-energy system. The analyzer fully complies with the requirements of EN 61000-4-30: 2011 class A.

The device is designed to work with networks:

  • With nominal frequency 50/60Hz,
  • With nominal voltage: 64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 400/690 V
  • DC network

Supported networks:

  • Single-phase
  • Two-phase with common N conductor
  • Three-phase star connection with and without N conductor
  • Three-phase delta

Possible measurements:

  • Measurements according to EN 50160
  • Voltage L1, L2, L3, N-PE : average, minimum, maximum and instantaneous values, range to 760V, ability to work with voltage transformers
  • Current L1, L2, L3, N (four inputs): average, minimum, maximum and instantaneous values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers
  • Crest factor for voltage and current
  • Frequency from 40Hz to 70Hz
  • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive)
  • Power recording: Budeanu method, IEEE 1459
  • Active, reactive, apparent energy
  • Power factor, cos φ tg φ
  • K factor (transformer overload caused by the harmonics)
  • Up to 50th harmonics for voltage and current
  • Total Harmonic Distortion (THD) for voltage and current
  • Short-term (PST) and long-term (PLT) flicker
  • Unbalance of voltage and current
  • Current events detection including waveforms recording
  • Current and voltage waveforms recording after each averaging period
  • Mains signalling up to 3000 Hz
  • Transients up to ±6000 V, max 10 MHz, minimal transient capturing time is 650 ns
  • All parameters meet Class A acc. IEC 61000-4-30 standard
Image: Black and blue test plugs and cable adapters, shown alone and inserted into terminal blocks of an electrical cabinet.
Image: Operator using an orange Sonel touch-screen instrument in front of an electrical cabinet with terminal wiring.
Image: Technician viewing test results on a tablet connected to an orange test unit wired into equipment inside a cabinet.
Image: Eight analysis software screens: waveforms, phasor diagram, data tables, harmonics bar chart and a 3D plot of power quality measurements.
SpecificationRangeResolutionAccuracy
AC voltage (TRMS)-0,0...760,0V0,01 % Unom±0,5% U nom
Crest FactorVoltage1,00...10,00 ( 1.65 for 690 V voltage)0,01±5%
Crest FactorCurrent1,00...10,00 ( 3,6 Inom)0,01± 5% m.v.
AC current TRMS-depending on clamp*0,01 % of nominal range±0,1% of nominal range (add clamps accuracy)
Frequency-40,00...70,00 Hz0,01Hz±0,01 Hz
Active, reactive, apparent and distortion power-depending of configuration (trasformers, clamp)up to 4 decimal placesdepends on configuration (transformers, clamp)
Active, reactive apparent energy-depending of configuration (transformers, clamp)up to 4 decimal placesthe same as above
cosφ and power factor (PF)-0,00...1,000,01±0,03
Tgφ-0,00...10,000,01depends on Active and Reactive power accuracy
Voltagesame as for AC voltage TRMSsame as for AC voltage TRMS±5%hU for Uh 1% Un ±0,05% nU for Uh < 1% Un
HarmonicsCurrentsame as for AC current TRMSsame as for AC current TRMS± 5% I h for Ih 3% In ± 0,15% I n for Ih < 3% In
Total Harmonics DistortionVoltage0,0..100,0%0,1%±5%
Total Harmonics DistortionCurrent0,0..100,0%0,1%±5%
Harmonics active and reactive power-depends on configuration (transformers, clamp)depends on current and voltage minimum value-
Angle between voltage and current harmonics--180,0...+180,0o0,1º±(hxo1)
K-Factor-1,0...50,00,1±10%
Flicker-0,20...10,000,01±5%

AMPERIS PRODUCTS S.Lagricultura, 34, Contacto 27003 c/ barbeito maría, 14 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, España info@amperis.com | www.amperis.com

SpecificationRangeResolutionAccuracy
UnbalanceVoltage and Current0,0...20,0%0,01 % Unom±0,15% (absolute error)
Mains signallingVoltagedepending on clamp*0,01 % of nominal range±0,15% hUfor 1...3% Uh ,5% Un for 3...15% Uh
Transients (max. 10 MHzVoltage±8000 V5V±(5% + 25 V)

*Clamp F-1/F-2/F-3:0..3000 A (10000 Ap-p) *Clamp C-4: 0..1000 A (3600 Ap-p)*Clamp C-5: 0..1000 A (3600 Ap-p)*Clamp C-6: 0..10 A (36 Ap-p) (without current transformers) *Clamp C-7: 0...100 A (360 Ap-p )

Available with other configurations