RAPIDOX 2100

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 4 pages · 204 KB)

Image: Rapidox 2100 gas analyser: display reading 20.96 % oxygen and pressure, O2 sensor and auxiliary connectors, navigation keypad and red power switch.

Rapidox 2100 Oxygen Analyzer

The Rapidox 2100 is a high-performance oxygen (O2) analyser fitted with a rugged long-life zirconia sensor on a remote cable, together with a type K thermocouple sensor; allowing direct in-process measurement of oxygen and temperature in the sample gas. The sensors provide fast and accurate analysis over the low ppm oxygen range in harsh environments up to 650°C.

Image: For customers requiring seamless integration into their product or process, the Rapidox 2100 can be supplied as an OEM solution. Please contact Amperis for further information.

Zirconia oxygen sensors are particularly suitable for monitoring inert atmospheres in aggressive industrial applications within manufacturing processes; this includes high temperature locations and vacuum atmospheres.

In rare instances where a zirconia sensors are unsuitable, an electrochemical sensor will be used instead. Electrochemical oxygen sensors are ideal for monitoring high oxygen applications, or where VOC’s, flammable gases, CO, H2 or He are present in the gas sample. Users have a choice between a sensor for low ppm measurements of 1ppm to 1%, or for high percent measurements in the 1ppm to 30% oxygen range.

Depending on the specification of the analyser, the sensor is normally housed in a remote metal manifold that allows gas to flow through and over the sensor surface, or provide a vacuum tight coupling to the sample point in a vacuum application. The exact design of the manifold housing depends on the application and can be situated up to 25 meters from the analyser using optional sensor extension cables. As well as a type K thermocouple sensor which is fitted as standard, a range of optional auxiliary pressure, vacuum and dewpoint sensors are available allowing multiple measurements in one instrument.

Configuration of the analyser allows for the instrument to be panel mounted or supplied within a wall mountable, IP65 weatherproof housing. The oxygen sensor can then be positioned remotely, up to 25 metres away in either a separate cabinet or as a standalone sensor. A printer can be attached to the instrument using the serial port for permanent record keeping of results. All Rapidox analysers come with full Windows software that allows for remote configuration and monitoring of readings, as well as a full data-logging package that includes live-time graphing of each sensor channel.

  • Data logging
  • Choice of O2 sensor technology
  • Type K Thermocouple
  • Fully configurable software
  • Two programmable alarms
  • Fast and accurate response
  • Operates on worldwide mains voltage
  • Simple calibration procedure
  • Password protection
  • Fully programmable outputs

AMPERIS PRODUCTS, S.L.

Applications

Image: Cube-shaped metal lattice structure resting on the palm of a hand.

Additive Manufacturing Gas Chemicals Glove Boxes Combustion Manufacturing

Metal Heat Treatment Research & Development

Accesories

Image: Numbered accessories: 1 gas cylinders in a case, 2 rack-mounted unit, 3 orange pump unit, 4 white wall-mounted enclosure, 5 valve and gauge panel, 6 sensor and flange adapter.
  • 1.Calibration Kit
  • 2.Multiplex Sampling System
  • 3.Gas Recovery Bag
  • 4.Wall Mount Cabinet
  • 5.Calibration Service
  • 6.Fittings and Filters

AMPERIS PRODUCTS, S.L. CONTACT

Sensor Specification
O2 Sensor Range10E-20ppm to 30% (zirconia) or 0-100% (electrochemical)
Oxygen Sensor Cable2m high temperature sheathed cable as standard. Fully shielded with a quick release plug. Extension cables available up to 25m total length
Sample Gas Flow Rate0.1 to 4 Litres per min (1 Litre per min recommended) Static gas and vacuum conditions also allowed
Thermocouple (Included)Type K, range 0-1250°C, ±1°C
Optional Pressure Sensor-1 to 0 bar vacuum, 0-5 and 0-10 bar gauge pressure as standard. Supplied on 2m cable with sample chamber. High precision versions available.
Optional H2O Sensor-100°C to +20°Cdp. Supplied on 2m cable with sample chamber
Analyser Specification
Supply Voltage90-260VAC, 50/60Hz
Power Consumption30W (max)
Analyzer Dimensions250mm X 263mm X 150mm (without optional handle kit fitted) Panel Mount 300mm wide X 4U high
Weigth3.5kg (Including sensor)
Display20 x 4 character OLED
Warm-up Time60 seconds at 20°C –
Operating Temperature & Operating5°C to 35°C, 900–1100 mbar absolute
Pressure–configurable) into minimum 5kΩ
Voltage Outputs0–5V (user-configurable) into minimum 5kΩ –configurable) into maximum 500Ω
Current Outputs4–20mA current loop (user-configurable) into maximum 500Ω
Digital Outputs–configurable) into maximum 500Ω RS232 (RS485 option available): data streamed on demand/Modbus RTU / Ethernet
Alarms High and LowRelay circuits. Fully user programmable
Sample Connections4mm ID / 6mm OD nipple type connected to metal manifold. Rectus or Swagelok options. Front or rear positioning
CalibrationUp to five user-selectable gas compositions (air is default)
FuseT2A H250V 5 x 20mm glass