Trailer-mounted mobile laboratory for on-site testing of dielectric PPE
Testing gloves, boots, blankets, hot sticks and voltage indicators at remote sites, without taking them to a fixed laboratory, calls for a complete high-voltage laboratory mounted on a trailer. The MSP-100SFT brings together, in a 7600 × 2270 × 2660 mm trailer, a 100/40 kV, 100 mA AC source, a 4-electrode bath for gloves and boots at 40 kV, the SD-3 stand for hot sticks up to 4 m at 100 kV every 300 mm, the SW-1 stand for voltage and phase indicators up to 52 kV and the IMT-40 stand for mats up to 1200 × 1200 mm, and tests under ASTM D120, ASTM F496 and IEC 60903.
Product Summary
Mobile laboratory MSP-100SFT is designed for testing of electrical safety PPE (Dielectric Gloves; Boots; Blankets; Mats; Hot Sticks; Dielectric Tools; Voltage and Phase indicators). All standard rubber items can be tested, even class 4.
All equipment is mounted on a trailer, which allows testing in field conditions at remote sites.
Product Description
Mobile laboratory MSP-100SF is designed to test the electric safety of PPE (Dielectric Gloves; Boots; Blankets; Mats; Hot Sticks; Dielectric Tools; Voltage and Phase indicators). All standard rubber items can be tested, even class 4. All equipment is mounted on trailer, which allows testing in field conditions, at remote sites.
Allows Testing under ASTM D120, F496 and IEC 60903 Standards.
Testing of personal protective equipment:
- Gloves - class 00, 0, 1, 2, 3 and 4;
- Botas - clase 0, 1, 2, 3 y 4;
- Sleeves -class 0, 1, 2, 3 and 4.
Testing of insulating equipment:
- Blankets, mats, covers - class 0, 1, 2, 3 and 4;
- Insulated tools and other electric equipment;
- Hot sticks - 100 kV, every 300mm. Up to 4 m length.
- Phase and voltage indicator - up to 52 kV.
Drying cabinet for 20 gloves:
All adjustments are controlled via menu - operated microprocessor control led system. With selection of test voltage, current limit and test time. Microprocessor control unit provides the user with menu based system - to select the type (class, length, new or retest) of rubber items for testing. This eliminates any chance for operator error and provides an extremely fast changeover from one class to another. Current readings of all positions are conveniently displayed on control panel, and peak current during the test is saved on screen, for easy record keeping.

MSP-100SFT key data
- Trailer: the MSP-100SFT is mounted on a trailer with a 5000 × 2200 × 2000 mm interior, overall dimensions of 7600 × 2270 × 2660 mm and a weight of about 2500 kg with the equipment.
- High-voltage source: 100/40 kV and 100 mA RMS maximum, single-phase 230 V supply (120 V 60 Hz to order), 4 kVA maximum power consumption, output voltage and current measurement error up to 3% and built-in timer.
- Gloves and boots: 4 electrodes for simultaneous testing of 4 gloves or 2 boots at up to 40 kV, with leakage current measurement on each glove, manual water filling, water storage tank and pump for filling and draining; gloves of class 00 to 4 and boots and sleeves of class 0 to 4.
- Hot sticks: SD-3 stand for three sticks at once up to 4 m long, tested at 100 kV every 300 mm.
- Indicators: SW-1 stand for phase comparators to EN 61481 and voltage indicators to EN 61243 up to 52 kV.
- Mats and blankets: IMT-40 stand for mats up to 1200 × 1200 mm at 40 kV, with replacement electrodes of various sizes for blankets, mats and covers of class 0 to 4.
- Control: menu-operated microprocessor to select the test voltage, current limit, test time and type of rubber item (class, length, new or retest); the peak current is held on screen. Includes a drying cabinet for 20 gloves.
- Standards: the MSP-100SFT allows testing under ASTM D120, ASTM F496 and IEC 60903 and can be equipped to customer specifications.
Frequently asked questions
What power supply does the MSP-100SFT need on site?
A single-phase 230 V outlet (or 120 V 60 Hz in the version to order), with 4 kVA maximum power consumption. The MSP-100SFT carries all the equipment on the trailer, about 2500 kg in total, plus a water storage tank and a pump to fill and drain the glove and boot test bath.
How many items does the MSP-100SFT test at once?
In the bath, 4 gloves or 2 boots at once at up to 40 kV, with leakage current measured on each glove; on the SD-3 stand, three hot sticks up to 4 m tested at 100 kV every 300 mm; and on the IMT-40 stand, mats up to 1200 × 1200 mm at 40 kV.