Skip to content

Accessible version

AHZJB-1200 — 6-phase relay protection test set

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 334 KB) · Source page: AHZJB-1200: 6-phase relay protection test set

Six voltages and six 30 A currents, up to 180 A in parallel, with built-in computer and display

AHZJB-1200

Image: AHZJB-1200 relay test set in three-quarter view: grey case with carrying handle, coloured terminals across the top of the panel, built-in display, trackball and numeric keypad.

Relay test equipment

AHZJB-1200

6-phase relay protection test set

Six voltage and six current channels, combinable for any protection test.

Product description

Twelve outputs in a single unit

The AHZJB-1200 generates six voltages and six currents that can be freely combined: four currents plus three, six voltages, six currents or all twelve outputs at once. It thus performs conventional three-phase tests and tests three-phase transformer differential protection with the currents of both windings.

High-fidelity signal

The outputs use modular linear amplifiers, not switch-mode ones: the waveform is clean from the smallest current up to the maximum, with no high-frequency noise to disturb the test. A digital signal processor with 32-bit computation and high-resolution D/A conversion generates each phase with low distortion and good linearity.

Main features

  • Built-in Windows computer, display, trackball and keyboard: no external PC needed.
  • USB port for connecting a PC or exchanging data.
  • 8 binary inputs (dry contact or voltage up to 250 V) and 4 binary outputs.
  • 110 V or 220 V auxiliary DC supply, adjustable from 80 to 110 %.
  • Soft start, self-diagnostics and protection against overtemperature, overcurrent, overvoltage and short circuit.
Image: AHZJB-1200 front panel: yellow, green, red and black voltage and current output terminals, blue binary input terminals and white binary output terminals, display, trackball and keypad.

AHZJB-1200: voltage and current outputs, binary inputs/outputs, display, trackball and keyboard

Image: Accessories laid out on a table: test leads with yellow, green, red and black plugs, four-wire cables, power cord, USB cable, crocodile clips in several colours and pin terminals.

Supplied accessories: test leads, clips, terminals and fuses

Test software

Test modules

AC and DC test, state sequence I and II, harmonic superposition, high and low frequency, power direction and impedance, synchronization, complete-set test I and II, distance and zero-sequence protection, impedance characteristic, differential protection, differential harmonics, integrated 6-35 kV line protection test and fault playback.

Tools

Short-circuit calculation, online vector diagram, symmetrical-component output, six-voltage interface, real-time logging of test data and reports that can be printed immediately.

Fault triggering

The transition from pre-fault to fault is triggered by time, by a key, by binary input c or by the pulse of an external GPS clock, so two test sets can test both ends of a line simultaneously.

Image: Software screen during a three-phase AC test: table with the amplitude and phase of each voltage and current and, on the right, the vector diagram with the phasors.

Three-phase AC voltage and current test with vector diagram

Image: Impedance characteristic search screen: test parameters on the left and, on the right, the R-X plane with the radial search lines.

Impedance characteristic search in the R-X plane

Applications and use

Relays

Signalling, time, auxiliary, current, overvoltage and undervoltage, sequence, synchronism-check, inverse-time, differential, directional power, impedance, synchronizing and frequency relays.

Protection

Line protection and auto-reclosing, distance and zero-sequence, voltage-blocked overcurrent, under-frequency and under-voltage load shedding, generator and transformer differential, loss of excitation, automatic synchronizer, busbar differential and fibre-optic line differential.

Binary inputs and outputs

The 8 inputs accept dry or wet contacts: 0-6 V is read as a closed contact and 11-250 V as an open contact. They are isolated from the analogue outputs and, with wet contacts, the positive pole goes to the +KM common. The 4 outputs are voltage-free relay contacts rated 220 V DC / 0.2 A and 220 V AC / 0.5 A.

Continuous current and thermal protection

Up to 10 A per phase the output can be held indefinitely; above that, the software limits its duration, the more so the higher the current, and cuts it off with an alarm. With all six currents in parallel, 180 A is held for up to 10 s.

Scope of supply

Test set, power cable, 10 A and 2 A fuses (5 of each), 4 four-wire cables, short and long test leads, crocodile clips in three sizes, plugs and pin terminals.

AHZJB-1200 — TECHNICAL SPECIFICATIONS (1/2)

Output channels6 voltage and 6 current; combinable as 4 + 3 currents, 6 voltages, 6 currents or 12 outputs
AC current per phase6 × 0-30 A, class 0.2
Grouped AC current3 × 0-60 A; 1 × 0-180 A with all 6 phases in parallel
Continuous current10 A per phase
Current output power450 VA per phase; 1000 VA with 6 phases in parallel (10 s at max. output)
DC current0-±10 A per phase, class 0.2; max. load voltage 20 V
AC voltage6 × 0-120 V phase-neutral, class 0.2; 0-240 V phase-phase
AC voltage output power80 VA per phase; 100 VA phase-phase
DC voltage0-±160 V per phase, class 0.2; 0-±320 V phase-phase
DC voltage output power70 VA per phase; 140 VA phase-phase
Frequency and harmonics0-1000 Hz (fundamental); harmonics up to 20th order

AHZJB-1200 — TECHNICAL SPECIFICATIONS (2/2)

Binary inputs8; dry contact (1-20 mA, 24 V) or wet contact (“0”: 0-6 V; “1”: 11-250 V)
Binary outputs4 dry contacts; 220 V DC / 0.2 A; 220 V AC / 0.5 A
Time measurement0.1 ms-9999 s; accuracy < 0.1 ms
Auxiliary DC supply110 V or 220 V, adjustable from 80 to 110 %; 1.5 A; 2 A / 250 V fuse
Signal generationDigital signal processor, 32-bit computation, high-resolution D/A conversion and linear amplifiers
ControlBuilt-in Windows computer, display, trackball and keyboard; USB for PC
Fault triggeringBy time, key, binary input or external GPS pulse
ProtectionSoft start, self-diagnostics and output blocking; overtemperature, overcurrent, overvoltage and short circuit
Power supply220 V AC
Scope of supplyTest set, power cable, fuses, test leads, clips, plugs and pin terminals