Skip to content

Accessible version

AHZJB-I — Three-phase relay protection test set

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 299 KB) · Source page: AHZJB-I: three-phase relay protection test set

Four voltages and three 40 A currents, up to 120 A in parallel, with stand-alone or PC operation

AHZJB-I

Image: AHZJB-I relay test set seen from the front: grey case with carrying handle, coloured voltage and current output terminals, blue binary input terminals and white binary output terminals, LCD display and rotary knob with two keys.

Relay test equipment

AHZJB-I

Three-phase relay protection test set

Compact three-phase set for stand-alone use or with a PC.

Product description

Full three-phase testing

The AHZJB-I generates four voltages—UA, UB, UC and the multifunction output UX—and three currents of up to 40 A, reaching 120 A in parallel. UX can be configured as 3U0, as a synchronism voltage or as any other voltage, so the unit covers everything from simple relays to distance, differential and synchronizing protection.

Two ways of working

Without a computer, it is operated from its backlit LCD display with a rotary knob and two step keys; the main menu offers ten tests. Connected to a PC via USB, the included software adds automatic tests, vector diagrams and reports.

Main features

  • Indicators on each current output warn of waveform distortion or open circuit.
  • 8 binary inputs (dry contact or voltage up to 250 V) and 4 binary outputs.
  • 110 V or 220 V auxiliary DC supply, adjustable from 80 to 110 %.
  • Portable: 400 × 300 × 180 mm and 22 kg.
  • Power supply 220 V AC ±10 %, 50/60 Hz.
Image: AHZJB-I front panel: at the top, the voltage and current output, binary input and binary output terminals; below, the LCD display and the rotary knob with two keys.

AHZJB-I: voltage and current outputs, binary inputs/outputs, LCD display and rotary knob

Image: Twelve numbered accessories on a grey background: test leads with coloured plugs, power cord, USB cable, crocodile clips in several colours, terminals, a disc and fuses.

Supplied accessories: test leads, clips, terminals, USB cable and fuses

Tests and software

Stand-alone tests

AC and DC test, high and low frequency, synchronization, power direction and impedance, differential, differential harmonics, complete-set test I and II and time measurement. Each value is set by turning the knob, and the two step keys raise or lower the value.

Tests from the PC

AC and DC test, state sequence, harmonic superposition, high and low frequency, power direction and impedance, synchronization, complete-set test I and II, distance and zero-sequence, impedance characteristic, differential, differential harmonics, 6-35 kV line protection and fault playback.

Time measurement

In the timing test the unit works as a seven-channel millisecond timer: it measures the closing and opening times of a circuit breaker and the difference between poles.

Image: Main menu on the display: AC Test, DC Test, Hi-LowFreq, Sync Test, Dire & Impe, Diff Test, DiffHarmonic, Group Test 1, Group Test 2, Time Test and PC Comm.

Main menu on the unit display: ten tests and communication with the PC

Image: AC Test screen: value, step and angle of Va, Vb, Vc, Ia, Ib and Ic, with Va at 100 V and Ia at 8 A, frequency 50 Hz, pick-up time 0.110 s and drop-off time 0.080 s.

AC test on the unit display, with pick-up and drop-off values

Applications and use

Relays and protection

Current, voltage, frequency, time, directional power, impedance and synchronism relays; line protection with auto-reclosing, distance and zero-sequence, transformer differential and 6-35 kV line protection.

Binary inputs and outputs

The 8 inputs accept dry or wet contacts at 0-250 V, with the positive pole on the +KM common, and are isolated from the analogue outputs. The 4 outputs are voltage-free contacts rated 220 V DC / 0.2 A and 220 V AC / 0.5 A.

Auxiliary supply

On the rear panel, a 110 V or 220 V DC source, adjustable from 80 to 110 % and rated 1.5 A maximum, powers the relay or the control circuit during the test.

Protection

10 A / 250 V main fuse and 2 A / 250 V fuses in the voltage circuits. Above 10 A per phase the output time is limited; with the three currents in parallel, 120 A for 10 s.

Scope of supply

Test set, power cable, USB cable, software disc, 10 A and 2 A fuses (5 of each), 2 four-wire cables, short and long test leads, crocodile clips in three sizes, plugs and pin terminals.

AHZJB-I — TECHNICAL SPECIFICATIONS (1/2)

Output channels4 voltage (UA, UB, UC and multifunction UX) and 3 current
AC current per phase3 × 0-40 A, class 0.2
Parallel AC current1 × 0-120 A with all 3 phases in parallel
Continuous current10 A per phase
Current output power450 VA per phase; 900 VA with 3 phases in parallel (10 s)
DC current0-±10 A per phase; 0-±30 A with 3 phases in parallel; class 0.5
AC voltage0-120 V phase-neutral, class 0.2; 0-240 V phase-phase
AC voltage output power80 VA per phase; 100 VA phase-phase
DC voltage0-±160 V per phase, class 0.5; 0-±320 V phase-phase
DC voltage output power70 VA per phase; 140 VA phase-phase
Frequency and harmonics20-1000 Hz (fundamental); harmonics up to 20th order

AHZJB-I — TECHNICAL SPECIFICATIONS (2/2)

Binary inputs8; dry contact or wet contact at 0-250 V
Binary outputs4 dry contacts; 220 V DC / 0.2 A; 220 V AC / 0.5 A
Time measurement0.1 ms-9999 ms; accuracy < 0.1 ms
Auxiliary DC supply110 V or 220 V, adjustable from 80 to 110 %; 1.5 A max.
ControlStand-alone with backlit LCD display, rotary knob and step keys; or from a PC via USB
FusesMain 10 A / 250 V; voltage circuits 2 A / 250 V
Power supply220 V AC ±10 %, 50/60 Hz
Operating temperature−10 °C to +50 °C
Dimensions400 × 300 × 180 mm
Weight22 kg
Scope of supplyTest set, power cable, USB cable, software, fuses, test leads, clips, plugs and pin terminals

Specifications subject to change without notice.

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote