AMPERIS AMPI-525 Multifunction Electrical Installation Meter

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 234 KB) · Source page: AMPI-525: multifunction installation tester

Loop, RCDs, earth, continuity and insulation up to 2500 V in one instrument

AMPI-525

Multifunction installation meters

Image: Sonel MPI-525 installation tester, front view, with orange housing, display showing a loop impedance of 1.21 Ω, keys and rotary selector.

AMPI-525

Multifunction installation meter

C/ María Barbeito, 14Contact Contact T [+34] 982 20 99 20
27003, Lugo, SpainT [+34] 982 20 99 20 info@amperis.com | www.amperis.com

Every commissioning measurement of an electrical installation, with insulation testing up to 2.5 kV.

Image: Earth resistance measurement with the AMPI-525 in the field

One case for the whole verification

The AMPI-525 measures short-circuit loop impedance with 0.01 Ω resolution — also in RCD-protected circuits without tripping —, tests AC, A and B type RCDs, measures earth resistance by the 3-pole method, continuity of protective conductors with ±200 mA and the phase sequence: everything required to commission an installation per the EN 61557 series.

Insulation up to 2500 V

Few multifunction meters test insulation at 2500 V: ranges follow IEC 61557-2 up to 9.99 GΩ, a built-in timer sets three periods from 1 to 600 s and two absorption coefficients are calculated automatically. With the optional AutoISO-2500 adapter, 3-, 4and 5-core cables are tested automatically without switching connections, and the object is always discharged after the test.

Main features

  • Automatic RCD mode: tA and IA from a single trip.
  • Contact electrode for instant PE connection checking.
  • Voltage (0…500 V) and mains frequency measurement.
  • Memory of 990 cells (57 500 records); USB 2.0 and radio.
  • Measurement with swapped L and N conductors.
  • IP54 housing with screen-protecting cover.

Applications and safety

Applications

  • Commissioning of installations in housing and industry.
  • Periodic electric-shock protection inspections.
  • Automatic insulation testing of multicore cables.
  • RCD verification in distribution boards.

Powered for the whole day

The 4.8 V 4.2 Ah NiMH battery with its Z-7 charger powers full working days; safety is rated CAT IV 300 V (CAT III 600 V) with double insulation. At 288 × 223 × 75 mm and about 2.2 kg, with reel leads of 15 and 30 m for earth testing and the WS-03 UNI-Schuko adapter in the standard set, the AMPI-525 is a complete site companion.

Reader software for the data, reporting software for the electric-shock protection documentation.

Software & applications

Two programs, one workflow

The documentation software manages reports, inspectors, test points and downloaded data

The 57 500 records of the AMPI-525 travel to the computer over USB 2.0 or the radio link. The free reader software downloads them, saves them in the simplest formats and prints them; the reporting software turns them into the full verification report of the installation.

Reports that write themselves

Loop, RCD, insulation, earth and continuity results are assigned to the points of the installation, and the reporting software composes the electric-shock protection document with inspectors, dates and conclusions — ready to deliver to the client.

What the software provides

  • Download over USB 2.0 or the wireless link.

Preview of a verification report of the installation, ready to print or export

  • Archive by clients, sites and measuring points.
  • Full verification reports of the installation.
  • Export to popular formats and printing.

AMPI-525 — MEASUREMENT DATA

Fault loop impedance ZL-PE, ZL-N, ZL-L

FunctionMeasurement rangeDisplay rangeResolutionAccuracy
Fault loop ZL-PE, ZL-N, ZL-L0.13…1999.9 Ω per IEC 615570.00…1999 Ω0.01 Ω±(5% m.v. + 3 digits)
Fault loop ZL-PE in RCD mode0.50…1999 Ω per IEC 615570.00…1999 Ω0.01 Ωfrom ±(6% m.v. + 5 digits)
RCD parameters — tA measurement (0.5 Function5, 1, 2, 5 IΔn) Measurement rangeDisplay rangeResolutionAccuracy
General/short-time delay RCD0…300 ms0…300 ms1 ms±(2% m.v. + 2 digits)
Selective RCD0…500 ms0…500 ms1 ms±(2% m.v. + 2 digits)
IA sinusoidal (AC type), 0.2…2.0 IΔn3.0…1000 mA3.0…1000 mA0.1 mA±5% IΔn
IA unidirectional (A type)3.5…700 mA3.5…700 mA0.1 mA±10% IΔn
IA direct (B type)2.0…1000 mA2.0…1000 mA0.1 mA±10% IΔn

RCD parameters — tA measurement (0.5, 1, 2, 5 IΔn)

Insulation resistance (per measuring voltage)

FunctionMeasurement rangeDisplay rangeResolutionAccuracy
Measuring voltage 50 V50 kΩ…250 MΩ per IEC 61557-20 kΩ…250 MΩ1 kΩ±(3% m.v. + 8 digits)
Measuring voltage 100 V100 kΩ…500 MΩ per IEC 61557-20 kΩ…500 MΩ1 kΩ±(3% m.v. + 8 digits)
Measuring voltage 250 V250 kΩ…999 MΩ per IEC 61557-20 kΩ…999 MΩ1 kΩ±(3% m.v. + 8 digits)
Measuring voltage 500 V500 kΩ…2.00 GΩ per IEC 61557-20 kΩ…2.00 GΩ1 kΩfrom ±(3% m.v. + 8 digits)
Measuring voltage 1000 V1000 kΩ…3.00 GΩ per IEC 61557-20 kΩ…3.00 GΩ1 kΩfrom ±(3% m.v. + 8 digits)
Measuring voltage 2500 V2.50 MΩ…9.99 GΩ per IEC 61557-20 kΩ…9.99 GΩ1 kΩfrom ±(3% m.v. + 8 digits)
Earth resistance and continuity FunctionMeasurement rangeDisplay rangeResolutionAccuracy
3-pole method0.5 Ω…1.99 kΩ per IEC 61557-50.00 Ω…1.99 kΩ0.01 Ωfrom ±(2% m.v. + 3 digits)
Continuity with ±200 mA0.12…400 Ω per IEC 61557-40.00…400 Ω0.01 Ω±(2% m.v. + 3 digits)
Low-current resistance0.0…1999 Ω0.0…1999 Ω0.1 Ω±(3% m.v. + 3 digits)

Earth resistance and continuity

Phase sequence indication: same/opposite direction; UL-L 95…500 V (45…65 Hz). Voltage measurement 0…500 V and mains frequency.

"m.v." = measured value

C/ María Barbeito, 14Contact Contact +T [+34] 982 20 99 20
27003, Lugo, Spain+T [+34] 982 20 99 20 info@amperis.com | www.amperis.com

AMPI-525 — TECHNICAL SPECIFICATIONS

Type of insulationDouble, per EN 61010-1 and IEC 61557
Measurement categoryCAT IV 300 V (CAT III 600 V)
Ingress protectionIP54
Power supplyNiMH 4.8 V 4.2 Ah battery; Z-7 charger
Memory of results990 cells, 57 500 records
Data transmissionUSB 2.0 and radio link
Operating temperature0…+50 °C
Storage temperature-20…+70 °C
Humidity20…90 %
Dimensions288 × 223 × 75 mm
Weightapprox. 2.2 kg
EMC requirementsEN 61326-1, EN 61326-2-2
Quality standardISO 9001