Amperis MMF universal battery charger Amperis universal battery charger with IGBT Technology
- The Most Energy Efficient technology available. •Universal charger for all types of batteries (multivoltage, multi-capacity and multichemistry) from single cells to complete batteries. •Full set of standard charging curves factory programmed and possibility to create and save customized charging curves of any type.
- From 200 to 600 VCA and from 0 to 700 VCC.
- The Amperis MMF is a universal charger, programmable and digitally controlled. It can work with batteries of any type and supports applications of any type (Formation, Conditioning, Recovery, Desulphation and Regeneration). It has a very complete set of charging curves. In addition the user can program new curves in a simple way.
- It is based on a new power conversion technology, which combines very high efficiency, unit power factor (PFC), universal capabilities and precise load control. The MMF charger ensures a minimal temperature rise in the battery during the recharge process, thanks to the ultra-filtered output current (perfectly constant charge current and zero ripple).
- The MMF is equipped with alphanumeric display and keypad, charge history logger, programable real-time clock and calendar, audible alarm and connectivity package.
Applications:
- Battery formation. • Battery test.
- Conditioning and desulfation.
Optional equipment:
- Submersible probe for battery temperature.
- Enclosure type IP54 or NEMA 3R.
- Extended data-logger with miniUSB port or Bluetooth.
Technical specifications
| AC INPUT | SAFETY TIMER | An independent safety timer turns the charger off in case of malfunction of the control panel. | |
|---|---|---|---|
| TYPE | MMF Universal Battery Charger Single-phase 220-230-240 VAC ± 10% | MECHANICAL AND E DIMENSIONS | in case of malfunction of the control panel. ENVIRONMENTAL CHARACTERISTICS CABINET A: 500 x 900 x 440 (mm) |
| STANDARD VOLTAGES | Three-phase 220-240, 400, 440, 480, 600 VAC ± 10% Frequency 50/60 Hz ± 5 Hz | DIMENSIONS (W x H x D mm) | CABINET A: 500 x 900 x 440 (mm) CABINET B: 620x 1050 x 550 (mm) |
| EFFICIENCY | >90% | ENCLOSURE TYPE | Steel enclosure. |
| POWER FACTOR | >90% | COOLING AUDIBLE NOISE | FORCED VENTILATION with active fan control. < 65 dBA at 1 meter. |
| POWER FACTOR | >90% DC OUTPUT | AUDIBLE NOISE | < 65 dBA at 1 meter. |
| DC OUTPUT | IP21 (Standard) | ||
| STANDARD VOLTAGES | From single battery cell to 600 VDC. | ENCLOSURE PROTECTION | IP21 (Standard) IP54 (Optional) |
| CURRENT RATINGS | From 50A to 500A | AMBIENT TEMPERATURE | Operation: -10/+50 ºC Storage: -10/+70 ºC |
| CHARGING CURVE | Completely configurable by the user. | AMBIENT TEMPERATURE ALTITUDE | Storage: -10/+70 ºC < 2000 m (According to EN62040-3) |
| CHARGING CURVE | Completely configurable by the user. PROTECCIÓN | ALTITUDE USER INTE | < 2000 m (According to EN62040-3) ERFACE AND CONNECTIVITY |
| WRONG BATTERY | The charger remains in stand-by mode and gives an | USER INTE USER INTERFACE | ERFACE AND CONNECTIVITY LCD Display + LEDs, keyboard and audible alarm. |
| AND REVERSE POLARITY | error message | USER INTERFACE | LCD Display + LEDs, keyboard and audible alarm. |
| ELECTRONIC OVERLOAD PROTECTION | Complete protection in case of output short circuit or overload. | CONNECTIVITY | Internal storage of 200 cycles (expandable to 600 with miniUSB, optional). BLUETOOTH Wireless extension. |
| WITHOUT AUXILIARY WIRES: When the battery is | BLUETOOTH Wireless extension. STANDARS | ||
| WITHOUT AUXILIARY WIRES: When the battery is connected, no arcing is generated at the connectors. If the battery is disconnected while it’s being charged, | STANDARS | ||
| If the battery is disconnected while it’s being charged, arcing is possible, (it’s necessary to turn off the charger | QUALITY | ISO 9001:2015 | |
| ANTI-ARCING | arcing is possible, (it’s necessary to turn off the charger before to disconnect the battery). | MARKING | CE |
| before to disconnect the battery). WITH AUXILIARY WIRES (RECOMMENDED): Full Anti-arcing protection in case of battery | EMC | IEC EN 61000-6-2, IEC EN 61000-6-4 | |
| Anti-arcing protection in case of battery disconnection, even while the charge is in progress. | SAFETY | IEC EN 50178, IEC EN 62040-1 | |
| disconnection, even while the charge is in progress. Self-test at each power-up (<10s). In the event of an | TEST RUN | IEC EN 62040-3 | |
| POWER-ON SELF-TEST | Self-test at each power-up (<10s). In the event of an error, an error message is displayed. | NORTH AMERICAN STANDARDS | UL 1564 “Industrial Battery Chargers” CSA 22.2 107.2-01 “Battery Chargers” |
| AUTOMATIC SHUTDOWN ON BATTERY | The charger is switched off (<3s) in case of disconnection of the battery during the charging | STANDARDS | CSA 22.2 107.2-01 “Battery Chargers” cCSAus Listed |
| ON BATTERY DISCONNECTION | disconnection of the battery during the charging process. | cCSAus Listed |
AMPERIS PRODUCTS S.Lagricultura, 34, Contacto 27003 Agricultura,34 +T [+34] 982 20 99 20 | F [+34] 982 20 99 11 lugo [spain]27003, Lugo, España info@amperis.com | www.amperis.com
The following table shows all available models of the MMF battery charger:
NOTE: Reported Efficiency and Power Factor values are AVERAGE values, measured over the entire charging cycle. Peak Efficiency and Power Factor are higher.
| MODEL | STANDARD VOLTAGE | CURRENT |
|---|---|---|
| MODEL | VOLTAGE | CURRENT |
| A-50 | 2-48V | 0-50A |
| A-100 | 2-48V | 0-1OOA |
| A-150 | 2-48V | 0-150A |
| A-200 | 2-48V | 0-200A |
| A-300 | 2-48V | 0-300A |
| B-50 | 2-80V | 0-50A |
| B-100 | 2-80V | 0-1OOA |
| B-150 | 2-80V | 0-150A |
| C-50 | 2-96V | 0-50A |
| C-100 | 2-96V | 0-1OOA |
| C-150 | 2-96V | 0-150A |
| C-200 | 2-96V | 0-200A |
| D-80 | 50-200V | 0-80A |
| E-50 | 50-400V | 0-50A |
| F-50 | 2-120V | 50A |
| F-100 | 2-120V | 100A |
Para otras configuraciones póngase en contacto con nosotros, indíquenos sus requerimientos y nos encargaremos de ofrecerle la solución que mejor se adapta a sus necesidades.