Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 8 pages · 210 KB) · Source page: AHZAQ: dielectric PPE insulation test system

Withstand testing of dielectric gloves, boots, blankets, rods and voltage detectors up to class 4

10 kVA / 100 kV, 8-position test bath

Image: Test rack with four water tanks holding insulating boots for dielectric testing, with electrodes lowered into them.

AHZAQ

Dielectric PPE insulation test system

A 10 kVA / 100 kV system that withstand-tests every class of dielectric PPE and insulated tooling in one bath.

Image: Control unit with printer, display and output and measurement terminals
Image: Item families covered: gloves, boots, blankets/mats, rods, insulated tools and voltage detectors

A complete insulation test system

The system withstand-tests dielectric rubber goods and insulated tooling up to class 4. The test bath holds eight pairs of boots or gloves at once and reads the leakage current of every position separately, while an infrared link keeps the control console fully isolated from the high-voltage side. The whole set can be trailer-mounted for on-site work at remote locations.

Items tested, by class

  • Dielectric gloves: classes 00 to 4.
  • Dielectric boots: classes 0 to 4.
  • Dielectric sleeves: classes 0 to 4.
  • Blankets, mats and covers: classes 0 to 4.
  • Insulated tools and other electrical equipment.
  • Hot sticks (insulating rods) up to 4 m, tested at 100 kV every 300 mm.
  • Capacitive voltage detectors of 35 kV and below.

The withstand test runs unattended, with an independent HV disconnect per channel and on-site report printing.

Control, automation and reports

Fully automatic withstand test

  • Ramp-up, hold, ramp-down and power-off run unattended once the test is started.
  • Independent high-voltage disconnect per channel, so a single fault does not stop the other seven tests.
  • Over-voltage and over-current protection, with a high-voltage hazard warning light.
  • A patented infrared link keeps the operating console fully isolated from the high-voltage circuit.

Console and display

A large LCD on the control console shows the eight leakage currents together with the test voltage, the test current and the timer, all at the same time, so the operator follows every position of the bath during the test without switching screens.

Records and reports

The system stores 60 test records and prints on-site reports on the built-in high-speed printer, so acceptance and periodic tests can be documented immediately after the withstand test finishes.

Safety

The test bath and its accessories carry a dedicated grounding container and the interlocks and disconnects described above; the equipment is designed for use by trained personnel following the applicable electrical-safety procedures.

Test voltage and power ratings
Rated capacity10 kVA
Rated output voltageUp to 100 kV, according to the test transformer fitted (50 kV or 100 kV version)
Output voltage rangeUp to 50.0 kV (50 kV transformer)
Voltage measurement error< 1% of U + 0.5% of full scale
Input current rangeUp to 50.0 A
Current measurement error< 0.5% of I + 0.5% of full scale

Two interchangeable test transformers are available: a 50 kV / 200 mA version and a 100 kV / 100 mA version, both rated 10 kVA at 220 V input.

8-position test bath
Test positions8, tested and read out simultaneously and independently
Leakage-current rangeUp to 25.0 mA
Leakage-current error< 1% ± 1 digit
Leakage-current resolution0.1 mA
Max. working voltage50 kV (class 4 test)
Steel test ball weight (Ø 4 mm)20 kg
System components: control and HV generation
Control deskHouses the display, the test controls and the infrared link that isolates it from the high-voltage side
Voltage-raising transformer (50 kV version)10 kVA, 50 kV rated output, 200 mA rated current, 220 V input
Voltage-raising transformer (100 kV version)10 kVA, 100 kV rated output, 100 mA rated current, 220 V input
High-voltage divider100 kV rated voltage, 1.5% accuracy
Protection resistor5 kΩ, 100 mA maximum current, 100 kV maximum voltage
Optional test accessories
Insulating-rod test bracket100 kV rated test voltage; whole-length test for 35 kV rods and segment testing for rods up to 110 kV; 8 test stations with a universal adjustment range
Insulating-pad test benchFor insulating clothing, blankets and pads; 100 kV rated, 1800 × 1000 mm working area; embedded central grounding electrode and stainless-steel test electrodes; casters for easy movement
Insulating-clothing electrode setsSleeve electrodes (one per size), chest electrode (one set), trouser electrodes (one per size) and insulating-blanket electrodes in matching sizes
Voltage-detector test stand35 kV rated, for capacitive voltage detectors of 35 kV and below; fixed ground electrode and motorised HV electrode with left/right travel, push-button and wireless remote control, and a graduated distance scale

These accessories are optional and are added to the base control desk / test bath / transformer set described on the previous page.

Standards and scope of supply
StandardsASTM D120, ASTM F496, IEC 60903
Base setControl desk, test bath (8 positions), voltage-raising transformer, high-voltage divider and protection resistor
Optional accessoriesInsulating-rod test bracket, insulating-pad test bench, insulating-clothing electrode sets and voltage-detector test stand

Insulated tools and other electrical equipment are tested with the base set; no additional accessory is required for them.