Thermal and visible fused on screen, with night vision up to 30 m
Thermal imaging cameras DLD-TS Dual-spectrum fixed camera: thermal and Full HD visible
DLD-TS
| C/ María Barbeito, 14 | Contact Contact T [+34] 982 20 99 20 |
|---|---|
| 27003, Lugo, Spain | T [+34] 982 20 99 20 info@amperis.com | www.amperis.com |
Two sensors in one enclosure: radiometric thermal imaging plus Full HD visible video, day and night.
Two spectra, one diagnosis
The IR-DLD-TS combines a thermal detector (640 × 512, 384 × 288 or 256 × 192) with a 1920 × 1080 visible camera. Picture-in-picture and dual-light fusion modes overlay both sources, which markedly improves temperature-measurement performance and simplifies target identification.
It also watches at night
A near-infrared fill light reaches 30 m, keeping the visible channel useful in complete darkness; alarm light and buzzer connections warn on site when a threshold is exceeded.
Main features
- 10 real-time moving points, 10 areas and 3 measurement lines with irregular shapes.
- Temperature output over Modbus RTU/TCP.
- One hardware alarm input and one output, plus light and buzzer.
- ONVIF Profile-S/G compatibility and POE power supply.
- IP66 outdoor enclosure with lightning and surge protection.
Applications and integration
Applications
- Continuous thermal monitoring of substation equipment and switchgear.
- Perimeter and process surveillance requiring visual identification.
- Fire prevention in warehouses and outdoor installations.
Integration
Temperature readings flow to PLC and SCADA systems over Modbus RTU/TCP, and both video channels join ONVIF-compatible management platforms; POE keeps the installation 2 down to a single Ethernet cable.
Field documentation
Fused imaging pinpoints which component heats up: the visible channel confirms the exact equipment while the thermal channel quantifies the anomaly.
DLD-TS — TECHNICAL SPECIFICATIONS
| Thermal detector | 640 × 512, 384 × 288 or 256 × 192 |
|---|---|
| Visible camera | 1920 × 1080 |
| Fill light | Near-infrared, 30 m range |
| Image modes | Picture-in-picture, dual-light fusion and other display modes |
| Measurement modes | 10 real-time moving points, 10 areas and 3 lines (max/min/average); irregular-shape drawing |
| Temperature output | Modbus RTU/TCP |
| Alarms | 1 hardware alarm input and 1 output; alarm light and buzzer connection |
| Video integration | ONVIF Profile-S/G compatible |
| Power supply | POE (Power over Ethernet) |
| Protection | IP66 outdoor enclosure with lightning and surge protection |