AMPERIS APQM-711 Power Quality Analyser (Class A)

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 6 pages · 232 KB) · Source page: APQM-711 wave quality analyzer

±8000 V transients at 10 MHz and remote operation over Wi-Fi or 4G

APQM-711

Power quality analysers

Image: Orange power quality analyser with colour display showing a phasor diagram, with voltage leads and current clamps connected.

APQM-711

Class A power quality analyser

Class A analysis for every network from 110 to 1000 V, operated entirely from a distance.

Image: The APQM-711 operated from a tablet next to the machine

Class A, with evidential value

The APQM-711 measures per class A of IEC 61000-4-30: voltage to ±0.1% Unom, frequency to ±0.01 Hz, flicker in class A per IEC 61000-4-15 and unbalance to ±0.15%. Five voltage inputs and four current inputs — up to 6 kA depending on the clamp — cover networks from 64/110 V to 480/830 V, in DC and from 40 to 70 Hz.

Transients and harmonics under the microscope

The transient recorder samples at 10 MHz and captures ±8000 V phenomena from 650 ns. Harmonics and interharmonics up to the 50th order, THD, the K factor of transformers, control signals up to 3000 Hz and powers after Budeanu and IEEE 1459 complete the analysis, with event waveforms up to 1 s and 30 s half-cycle RMS graphs.

Main features

  • Built-in GSM 4G LTE modem for remote reading.
  • Wi-Fi module for local operation without cables.
  • GPS receiver: synchronised clock and anti-theft SMS alert.
  • Four-quadrant analysis for producers and consumers.
  • Voltage and current events with oscillograms.
  • EN 50160, IEEE 519 and NEC 220.87 reports.

Applications and operation

Applications

  • Certifiable analyses and disputes with the distributor.
  • Unattended measurement campaigns at substations and networks.
  • Photovoltaic and wind farms in four quadrants.
  • Investigation of switching and lightning transients.

Operated from anywhere

With no display of its own, the APQM-711 is commanded from the PC analysis software (Windows) or the mobile application (Android): configuration, real-time viewing of waveforms, phasors and harmonics, and download of the records over Wi-Fi or the mobile network — the user supervises the measurement far from the disturbance zones.

The analysis software operates the instrument locally over Wi-Fi or remotely over the mobile network.

Software & applications

Image: Time plots of the recorded voltages and currents with zoom over any interval

Operated from the office

The PC analysis software configures the APQM-711, follows the measurement in real time and downloads the records over Wi-Fi or the integrated GSM 4G LTE modem; the Android mobile application does the same from a tablet next to the machine.

The event and its waveform

Time plots, harmonics and interharmonics up to the 50th order, flicker and unbalance are examined in interactive graphs; dips, swells, interruptions and ±8000 V transients appear in an event list, each linked to its oscillogram, and the EN 50160 report documents compliance.

What the software provides

  • Remote reading over Wi-Fi or the 4G LTE modem.
  • Mobile application for monitoring on Android.
  • Event list with the waveform of each disturbance.
Image: Event list with dips, swells and interruptions, each linked to its waveform
  • EN 50160, IEEE 519 and NEC 220.87 reports.

APQM-711 — MEASUREMENT DATA

Analyser parameters

ParameterMeasuring rangeMax. resolutionAccuracy
Alternating voltage (TRMS)0.0…1000.0 V (UL-N)4 significant digits±0.1% Unom
Crest factor (voltage)1.00…10.00 (≤1.65 / 690 V)0.01±5%
Crest factor (current)1.00…10.00 (≤3.6 / Inom)0.01±5%
Alternating current (TRMS)depending on clamp*4 significant digits±0.1% Inom
Frequency40.00…70.00 Hz0.01 Hz±0.01 Hz
P, Q, D, S powerdepending on configuration (transducers, clamps)4 significant digitsdepending on configuration (transducers, clamps)
Active/reactive/apparent energydepending on configuration (transducers, clamps)4 significant digitsas power error
cosφ and power factor (PF)-1.00…1.000.01±0.03
tanφ-10.00…10.000.01depends on P and Q error
Voltage harmonicsDC, 1…50as voltage TRMS±0.05% Unom (<1% Unom); ±5% m.v. (≥1%)
Current harmonicsDC, 1…50as current TRMS±0.15% Inom (<3% Inom); ±5% m.v. (≥3%)
THD (U and I)0.0…100.0%0.1%±5%
K factor1.0…50.00.1±10%
Flicker PST/PLT0.20…10.000.01±5%
Unbalance (U and I)0.0…20.0%0.1%±0.15%
Control signals (voltage)≤15% Unom; 5.00…3000.00 Hz4 significant digits±0.15…±5%
Transients (voltage)±8000 V4 significant digits±(5% + 25 V)

Measurements in class A per IEC 61000-4-30; flicker in class A per IEC 61000-4-15. Transients: PQM-711 only, 10 MHz sampling, minimum 650 ns.

* Depending on the clamp: F-xA1 0…1500 A, F-xA 0…3000 A, F-xA6 0…6000 A; C-4A/C-5A 0…1000 A (C-5A also 1400 A DC); C-6A 0…12 A; C-7A 0…100 A.

"m.v." = measured value

APQM-711 — TECHNICAL SPECIFICATIONS

Measurement classClass A per IEC 61000-4-30
Voltage inputs5; networks from 110 to 1000 V
Current inputs4; up to 6 kA depending on the clamp
Rated networks64/110…480/830 V; DC; 40…70 Hz; WYE, Delta and Aron systems
RecordingEvents with waveforms up to 1 s and RMS1/2 graphs of 30 s
CommunicationsGSM 4G LTE modem, Wi-Fi, GPS (anti-theft SMS alert)
OperationPC software (Windows) and mobile app (Android)
SoftwareAnalysis software with EN 50160, IEEE 519 and NEC 220.87 reports
Quality standardISO 9001