AMPERIS MPI-530-IT Multifunction Meter for IT Networks

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 7 pages · 239 KB) · Source page: AMPI-530-IT: multifunction IT tester

Full installation verification, also in isolated IT networks

MPI-530-IT

Multifunction electrical installation meters

Image: Sonel MPI-530-IT installation tester with display showing a waveform and readings, keypad and rotary selector.

MPI-530-IT

Multifunction meter for IT networks

C/ María Barbeito, 14Contact Contact T [+34] 982 20 99 20
27003, Lugo, SpainT [+34] 982 20 99 20 info@amperis.com | www.amperis.com

Loop, RCD, insulation, earth and continuity measurements, with RCD testing in IT systems.

Image: The MPI-530-IT ready for field work

A multifunction meter prepared for IT systems

The MPI-530-IT performs every verification measurement of an electrical installation and adds a distinctive capability: it tests general and selective RCDs from 10 to 1000 mA also in isolated IT networks, the earthing systems used where supply continuity is critical, such as hospital operating theatres, mines and certain industrial plants.

All the measurements of the family

Fault loop impedance is measured with 23 A (44 A phase-to-phase) in the 95…440 V range with 0.01 Ω resolution, or with 15 mA in RCD circuits without tripping. Insulation reaches 10 GΩ with test voltages of 50 to 1000 V and the AutoISO-1000C adapter, earth is measured by four methods plus Wenner soil resistivity, PE continuity uses ±200 mA in both directions and a probe measures light intensity; the recorder logs harmonics up to the 40th and THD.

Main features

  • RCD testing of 10 to 1000 mA also in isolated IT systems.
  • Fault loop with 23 A (44 A phase-to-phase) and 0.01 Ω resolution.
  • Insulation up to 10 GΩ at 50 to 1000 V; AutoISO-1000C adapter.
  • Earth by four methods and Wenner soil resistivity.
  • Bidirectional PE continuity with ±200 mA and quick PE check.
  • Tree memory with USB 2.0 and Bluetooth communication.

Applications and design

Applications

  • Verification of installations with IT earthing systems: hospitals, mining, industry.
  • Electric shock protection measurements to IEC 61557 in LV installations.
  • RCD testing, PE continuity and earth resistance surveys.
  • Basic mains diagnostics with harmonics, THD and phase sequence.

Robust and autonomous design

With its IP54 housing, CAT IV 300 V category, 288 × 223 × 75 mm case and roughly 2.5 kg, the MPI-530-IT works from 0 to +50 °C powered by five LR14 cells or a 4.8 V 4.2 Ah NiMH battery, charged from the mains or a 12 V car socket.

The measurements downloaded from the meter become complete verification protocols of the installation.

Software & applications

Reading the tree memory

Image: The documentation software manages reports, inspectors, test points and downloaded data

The free PC reading software empties the tree memory of the MPI-530-IT — clients, objects and measuring points — through the USB 2.0 port or the Bluetooth link, shows every result on screen and prints it or exports it to popular formats on any Windows computer.

Documentation software

A documentation package turns the downloaded data into complete verification reports: it manages inspectors, owners of the installation, test points and fuses, attaches the measurements to each circuit and produces the protocol of the acceptance or periodic test, ready to print or to save as a PDF file.

What the software provides

  • Free reading software plus a report generation package.

Preview of a verification report of the installation, ready to print or export

  • Database of clients, objects, inspectors and test points.
  • Verification protocols ready to print or export to PDF.
  • Works with the results of all the meter functions.
MPI-530-IT — TECHNICAL SPECIFICATIONS
StandardsIEC 61557; RCD testing also in IT systems
IT networksLoop and RCD measurements in isolated systems
Fault loopZ L-PE, L-N, L-L: 0.13…1999.9 Ω; 23 A (44 A ph-ph)
Loop with RCDWithout tripping: 0.50…1999 Ω with 15 mA
RCD testingGeneral and selective; 10…1000 mA; tA and IA
Insulation50/100/250/500/1000 V; up to 10 GΩ; AutoISO-1000C
ContinuityPE and bondings with ±200 mA; 0.12…400 Ω
Earth3p, 4p, 3p+clamp and 2 clamps; Wenner resistivity
Light intensityWith external probe; reading in lx or fc
RecorderU up to 500 V; harmonics to 40th; THD
Memory6000 cells and 10 000 records; tree structure
CommunicationUSB 2.0 and Bluetooth
Power supply5 × LR14 cells or NiMH 4.8 V 4.2 Ah; charger
Measuring categoryCAT IV 300 V / CAT III 600 V; IP54
Operating temperature0…+50 °C
Dimensions and weight288 × 223 × 75 mm; approx. 2.5 kg

MPI-530-IT — MEASUREMENT DATA (1/2)

Electrical installation measurements

Measurement functionMeasuring rangeDisplay rangeResolutionAccuracy
Fault loop impedance Z, Z, Z
ZL-PE, ZL-N, ZL-L Z RCD (without tripping the RCD)0.13 Ω…1999.9 Ω (IEC 61557)0.000 Ω…1999.9 Ωfrom 0.001 Ωfrom ±(5% m.v. + 0.03 Ω)
ZL-PE RCD (without tripping the RCD)from 0.50 Ω…1999 Ω (IEC 61557)0.00 Ω…1999 Ωfrom 0.01 Ωfrom ±(6% m.v. + 5 digits)
RCD parameters — tA at 0.5 / 1 / 2 / 5 IΔn; IA at 0.2…2.0 t — general and short-time delay RCDs (TN/TT)0 IΔn
tA — general and short-time delay RCDs (TN/TT)0 ms…300 ms0 ms…300 ms1 ms±(2% m.v. + 2 digits)
tA — general and short-time delay RCDs (IT mains)0 ms…400 ms0 ms…400 ms1 ms±(2% m.v. + 2 digits)
tA — selective RCDs0 ms…500 ms0 ms…500 ms1 ms±(2% m.v. + 2 digits)
IA — sinusoidal residual current (type AC)3.3 mA…1000 mA3.3 mA…1000 mAfrom 0.1 mA±5% IΔn
IA — unidirectional current, also with 6 mA DC bias (type A)3.5 mA…700 mA3.5 mA…700 mAfrom 0.1 mA±10% IΔn
IA — direct residual current (type B)2.0 mA…1000 mA2.0 mA…1000 mAfrom 0.1 mA±10% IΔn
Earth resistance and soil resistivity
3- and 4-pole methodfrom 0.50 Ω…1.99 kΩ (IEC 61557-5)0.00 Ω…1.99 kΩfrom 0.01 Ωfrom ±(2% m.v. + 3 digits)
3-pole + clamp method0.00 Ω…1.99 kΩ0.00 Ω…1.99 kΩfrom 0.01 Ω±(8% m.v. + 4 digits)
2-clamp method0.00 Ω…99.9 kΩ0.00 Ω…99.9 kΩfrom 0.01 Ωfrom ±(10% m.v. + 4 digits)
Soil resistivity0.0 Ωm…99.9 kΩm0.0 Ωm…99.9 kΩmfrom 0.1 Ωmdepends on the accuracy of the RE measurement
Insulation resistance
UISO = 50 V50 kΩ…250 MΩ (IEC 61557-2)0 kΩ…250 MΩfrom 1 kΩfrom ±(3% m.v. + 8 digits)
UISO = 100 V100 kΩ…500 MΩ (IEC 61557-2)0 kΩ…500 MΩfrom 1 kΩfrom ±(3% m.v. + 8 digits)
UISO = 250 V250 kΩ…999 MΩ (IEC 61557-2)0 kΩ…999 MΩfrom 1 kΩfrom ±(3% m.v. + 8 digits)
UISO = 500 V500 kΩ…2.00 GΩ (IEC 61557-2)0 kΩ…2.00 GΩfrom 1 kΩfrom ±(3% m.v. + 8 digits)
UISO = 1000 V1000 kΩ…9.99 GΩ (IEC 61557-2)0 kΩ…9.99 GΩfrom 1 kΩfrom ±(3% m.v. + 8 digits)

"m.v." – measured value.

MPI-530-IT — MEASUREMENT DATA (2/2)

Electrical installation measurements (continued)

Measurement functionMeasuring rangeDisplay rangeResolutionAccuracy
Continuity of protective conductors and eequipotential bondings
With ±200 mA test current0.12 Ω…400 Ω (IEC 61557-4)0.00 Ω…400 Ωfrom 0.01 Ω±(2% m.v. + 3 digits)
Low-current measurement0.0 Ω…1999 Ω0.0 Ω…1999 Ω0.1 Ω±(3% m.v. + 3 digits)
Light intensity
In lux (lx)0 lx…399.9 klx0 lx…399.9 klxfrom 0.001 lxfrom ±(2% m.v. + 5 digits)
In foot-candles (fc)0 fc…39.99 kfc0 fc…39.99 kfcfrom 0.001 fcfrom ±(2% m.v. + 5 digits)

Phase sequence indication: same direction (correct) / opposite direction (incorrect); UL-L 95…500 V, 45…65 Hz.

Single-phase power quality recorder

ParameterMeasuring rangeMax. resolutionAccuracy
Alternating voltage (TRMS)0.0…500 V0.1 Vfrom ±(2% m.v. + 2 digits)
Alternating current (TRMS)depending on the clamp*0.1 mAfrom ±(5% m.v. + 3 digits)
Frequency45.0…65.0 Hz0.1 Hz±(0.1% m.v. + 1 digit)
Active, reactive, apparent and distortion power0…1.5 MW / Mvar / MVA1 W / var / VAfrom ±(7% m.v. + 3 digits)
cosφ and power factor (PF)0.00…1.000.01unspecified
Voltage harmonics0.0…500 V0.1 Vfrom ±(5% m.v. + 3 digits)
Current harmonicsdepending on the clamp*as for current (TRMS)from ±(5% m.v. + 3 digits)
THD of voltage and current0.0…999.9% (relative to the fundamental)0.1%±5%

* F-1A, F-2A, F-3A clamps: 0…3000 A AC (10 000 Ap-p); C-3: 0…1000 A AC (3600 Ap-p); C-6A: 0…12 A AC (36 Ap-p). The current accuracy does not include the clamp error. Recorder for 110/190 V…240/415 V single-phase mains, 50/60 Hz.

"m.v." – measured value.