Up to 60 kW and 800 V DC per parallelable unit
Battery charging and maintenance equipment
High-voltage DC fast charging stations
DC fast charging for lithium-ion and any other battery chemistry, indoors or outdoors.
Product overview
Fast charging without borders
The HPS-HV family of DC fast charging stations is optimised for lithium-ion batteries and supports batteries of any type, chemistry, voltage and size. Third-generation IGBT-Hybrid power conversion combines performance, energy efficiency and robustness, with standard powers from 10 to 60 kW, outputs of 12-650 V DC (250-800 V DC in the H models) and a parallelable design that grows with the fleet.
Efficiency that pays for itself
Maximum efficiency exceeds 97 % with a power factor above 0.99, input current distortion below 15 % and output ripple under 8 % peak-to-peak; standby consumption stays below 10 W. The smart LCD interface manages charging priorities, timing, energy limiting and peak shaving.
Main features
- Multi-vehicle operation with automatic battery/EV recognition.
- Preprogrammed standard charging curves for quick set-up.
- Integrated datalogger for troubleshooting and optimisation.
- Automatic compensation of the DC cable voltage drop.
- CANBUS interface for BMS with multiple protocols and data rates.
- Indoor and outdoor versions; worldwide supply voltages and certifications.
Applications and options
Applications
- Fleets of industrial, commercial and passenger electric vehicles.
- Forklifts and airport ground support equipment (optional GSE version).
- Cold rooms and mining equipment (optional CME version).
- Fast and opportunity charging in 24/7 operations.
Options
The stations accept a stacklight for charger and battery status, an auto-watering system, an air pump for electrolyte recirculation, a charging stand with cable management and integration with wireless battery identification modules.
HPS-HV — TECHNICAL SPECIFICATIONS
COMMON SPECIFICATIONS
| AC input voltage | 3×400/415/440 V AC (others on request) |
|---|---|
| Output voltage range (standard) | 12-650 V DC |
| Output voltage range (extended) | 250-800 V DC |
| Safety, EMC and environmental standards | IEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS |
STANDARD MODELS (12-650 V DC)
| Model | HPS.M12 | HPS.M20 | HPS.M24 | HPS.M30 | HPS.M36 | HPS.M50 | HPS.M60H |
|---|---|---|---|---|---|---|---|
| Output power | 12 kW | 20 kW | 24 kW | 30 kW | 36 kW | 50 kW | 60 kW |
| Max DC current | 150 A | 150 A | 150 A | 150 A | 150 A | 150 A | 150 A |
| AC input current @ 400 V AC | 20 A | 32 A | 40 A | 50 A | 60 A | 83 A | 100 A |
EUROPE, ASIA, OCEANIA AND SOUTH AMERICA (EXTENDED DC RANGE)
| Model | HPS.H50 | HPS.H60 |
|---|---|---|
| Output power | 50 kW | 60 kW |
| Max DC current | 100 A | 100 A |
| AC input current @ 400 V AC | 83 A | 100 A |
Models for Europe, Asia, Oceania and South America (3×400/415/440 V AC). Other AC input voltages, including North American versions, available on request. Parallelable design.
HPS-HV — TECHNICAL SPECIFICATIONS
DIMENSIONS — INDOOR VERSION (UP TO 36 kW)
| Width 717 mm |
|---|
| Depth 559 mm |
| Height 1210 mm |
DIMENSIONS — OUTDOOR VERSION (UP TO 60 kW)
| Dimension | TM | TQ |
|---|---|---|
| Width | 887 mm | 870 mm |
| Depth | 716 mm | 689 mm |
| Height | 1318 mm | 1611 mm |