Desulphation, testing and formation from single cells to 96 V packs
Battery charging and maintenance equipment
Universal battery charger and conditioner
Programmable multi-voltage charging for the whole life cycle of lead-acid and lithium batteries.
Product overview
One charger for the whole workshop
The XMV is a programmable multi-voltage charger and conditioner for service centres, laboratories and battery regeneration workshops. It manages the entire battery life cycle — first formation charge, validation tests and desulphation of degraded units — on any chemistry: vented, AGM and gel lead-acid or LFP, NMC and LTO lithium, from single 2 V cells to packs of 96/120 V nominal.
Recovery with laboratory precision
Field-tested desulphation algorithms break down internal resistance and restore lost capacity in sulphated batteries, while a regulated, filtered output with minimal ripple suits lithium cell balancing and BMS recalibration. Full digital control adapts the curve to the battery response, and integrated diagnostics detect short-circuited cells before treatment.
Main features
- Output of 0-150 V DC with 3 to 36 kW and up to 600 A.
- Single-phase (110-230 V) or three-phase (400-600 V) supply.
- Automatic cycling of charge-rest or charge-discharge with an XD unit.
- Portable versions on wheels or stationary for charging rooms.
- Power factor above 0.98 and standby consumption below 10 W.
- Protection against overload, overtemperature and reverse polarity.
Applications and configurations
Applications
- Recovery and desulphation of lead-acid batteries.
- Balancing and testing of lithium packs during test cycles.
- Formation charges and validation tests in laboratories.
- Battery Cycler configuration paired with the XD discharger (XD-Combo).
Built for the workshop
The cabinet withstands acid vapours and workshop temperatures, with the control panel oriented towards the operator in the portable versions; stationary units up to 36 kW handle large-capacity packs in charging rooms and intensive test laboratories.
USA AND CANADA
| Model | XMV.12.US | XMV.12.NA | XMV.15.NA | XMV.20.NA | XMV.24.NA | XMV.36.NA |
|---|---|---|---|---|---|---|
| Maximum output power | 12 kW | 12 kW | 15 kW | 20 kW | 24 kW | 36 kW |
| DC output voltage range | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC |
| Max DC current @ 70/130/150 V DC | 200/120/100 A | 200/120/100 A | 250/150/120 A | 320/190/150 A | 400/230/200 A | 600/360/280 A |
| Connector | Single | Single | Single | Single or dual | Single or dual | Single or dual |
| AC input voltages | 3×208/240/480 V AC | 3×480/600 V AC | 3×480/600 V AC | 3×480/600 V AC | 3×480/600 V AC | 3×480/600 V AC |
| AC input current | 39 A @ 208 V AC / 17 A @ 480 V AC | 17 A @ 480 V AC / 14 A @ 600 V AC | 20 A @ 480 V AC / 17 A @ 600 V AC | 27 A @ 480 V AC / 22 A @ 600 V AC | 34 A @ 480 V AC / 27 A @ 600 V AC | 50 A @ 480 V AC / 40 A @ 600 V AC |
| Power factor | >0.98 | >0.98 | >0.98 | >0.99 | >0.99 | >0.99 |
| Idle power | <10 W | <10 W | <10 W | <10 W | <10 W | <10 W |
| Cabinet type | TL | TL | TL | TP | TP | TP |
Safety: UL 1564 4th Edition 2015 “Industrial Battery Chargers”; CSA C22.2 No. 107.2-01 R2016 “Battery Chargers”. Standards: NRTL certification QPS, file LR1649.
EUROPE, ASIA, OCEANIA AND SOUTH AMERICA
| Model | XMV.12.EU | XMV.15.EU | XMV.20.EU | XMV.24.EU | XMV.30.EU | XMV.36.EU |
|---|---|---|---|---|---|---|
| Maximum output power | 12 kW | 15 kW | 20 kW | 20 kW | 30 kW | 40 kW |
| DC output voltage range | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC | 2-150 V DC |
| Max DC current @ 70/130/150 V DC | 200/120/100 A | 250/150/120 A | 320/190/150 A | 400/230/200 A | 500/300/240 A | 600/360/280 A |
| Connector | Single | Single | Single | Single | Single or dual | Single or dual |
| AC input voltages | 3×400 V AC | 3×400 V AC | 3×400 V AC | 3×400 V AC | 3×400 V AC | 3×400 V AC |
| AC input current | 20 A | 25 A | 32 A | 41 A | 48 A | 63 A |
| Power factor | >0.98 | >0.98 | >0.99 | >0.99 | >0.99 | >0.99 |
| Idle power | <10 W | <10 W | <10 W | <10 W | <10 W | <10 W |
| Cabinet type | TL | TL | TP | TP | TP | TP |
Safety, EMC and environmental: IEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS.
EUROPE, ASIA, OCEANIA AND SOUTH AMERICA (EXTENDED DC RANGE)
| Model | XMV.E.20.EU | XMV.E.24.EU | XMV.E.30.EU | XMV.E.36.EU |
|---|---|---|---|---|
| Maximum output power | 20 kW | 20 kW | 30 kW | 40 kW |
| DC output voltage range | 2-180 V DC | 2-180 V DC | 2-180 V DC | 2-180 V DC |
| Max DC current @ 70/130/150/180 V DC | 220/190/150/80 | 220/220/200/100 | 220/220/220/125 | 220/220/220/150 |
| Connector | Single | Single | Single or dual | Single or dual |
| AC input voltages | 3×400 V AC | 3×400 V AC | 3×400 V AC | 3×400 V AC |
| AC input current | 32 A | 41 A | 48 A | 63 A |
| Power factor | >0.99 | >0.99 | >0.99 | >0.99 |
| Idle power | <10 W | <10 W | <10 W | <10 W |
| Cabinet type | TP | TP | TP | TP |
Safety, EMC and environmental: IEC 60335-1:2010; EN IEC 61000-6-2:2019; EN 61000-6-4:2007; EN 61000-6-4:2007/A1:2011; 2011/65/EU RoHS.
PORTABLE UNITS (EUROPE AND USA AC INPUT)
| Model | XMV.M.50.EU | XMV.M.80.EU | XMV.M.50.US | XMV-2M.160.EU |
|---|---|---|---|---|
| Maximum output power | 3 kW | 3 kW | 3 kW | 6 kW |
| DC output voltage range | 2-120 V DC | 2-70 V DC | 2-120 V DC | 2-70 V DC |
| Max DC current @ 24/48/80 V DC | 50/50/25 | 80/50/X | 50/50/25 | 160/100/X |
| Connector | Single | Single | Single | Single |
| AC input voltages | 1×230 V AC | 1×230 V AC | 1×208/240 V AC | 1×208/240 V AC |
| AC input current | 15 A | 15 A | 20 A | 32 A |
| Power factor | >0.9 | >0.9 | >0.9 | >0.9 |
| Idle power | <10 W | <10 W | <10 W | <10 W |
| Cabinet type | TD | TD | TD | TL |
Safety: EU models per IEC 60335-1:2010, EN IEC 61000-6-2:2019, EN 61000-6-4:2007, EN 61000-6-4:2007/A1:2011, 2011/65/EU RoHS; US model per UL 1564 4th Ed. 2015 and CSA C22.2 No. 107.2-01 R2016 (NRTL QPS, file LR1649).
DIMENSIONS — STANDARD CABINETS (IP21)
| Cabinet | TD | TL | TP |
|---|---|---|---|
| Width | 335 mm | 538 mm | 717 mm |
| Depth | 690 mm | 487 mm | 559 mm |
| Height | 530 (756 with raised keyboard) mm | 926 mm | 1210 mm |
DIMENSIONS — OUTDOOR CABINETS (IP54)
| Cabinet | TN | TM |
|---|---|---|
| Width | 659 mm | 887 mm |
| Depth | 612 mm | 716 mm |
| Height | 1019 mm | 1318 mm |