Skip to content

Accessible version

DLD-TS — Dual-spectrum fixed camera: thermal and Full HD visible

Accessible HTML version of the document: the same text as the PDF, with headings, tables and a description of each image. Download the original PDF (PDF · 4 pages · 1225 KB) · Source page: IR-DLD-TS: dual-spectrum thermal camera

Thermal and visible fused on screen, with night vision up to 30 m

IR-DLD-TS

Image: Dual-spectrum bullet camera with a white housing: thermal lens, visible-light lens and illuminators on the front.

Thermal imaging cameras

DLD-TS

Dual-spectrum fixed camera: thermal and Full HD visible

Two sensors in one enclosure: radiometric thermal imaging plus Full HD visible video, day and night.

Product overview

Two spectra, one diagnosis

The IR-DLD-TS combines a thermal detector (640 × 512, 384 × 288 or 256 × 192) with a 1920 × 1080 visible camera. Picture-in-picture and dual-light fusion modes overlay both sources, which markedly improves temperature-measurement performance and simplifies target identification.

It also watches at night

A near-infrared fill light reaches 30 m, keeping the visible channel useful in complete darkness; alarm light and buzzer connections warn on site when a threshold is exceeded.

Main features

  • 10 real-time moving points, 10 areas and 3 measurement lines with irregular shapes.
  • Temperature output over Modbus RTU/TCP.
  • One hardware alarm input and one output, plus light and buzzer.
  • ONVIF Profile-S/G compatibility and POE power supply.
  • IP66 outdoor enclosure with lightning and surge protection.
Image: Dual-spectrum camera: thermal detector and visible optics with IR fill light. Dual-spectrum bullet camera with a white housing: thermal lens, visible-light lens and illuminators on the front.

Applications and integration

Applications

  • Continuous thermal monitoring of substation equipment and switchgear.
  • Perimeter and process surveillance requiring visual identification.
  • Fire prevention in warehouses and outdoor installations.

Integration

2

Temperature readings flow to PLC and SCADA systems over Modbus RTU/TCP, and both video channels join ONVIF-compatible management platforms; POE keeps the installation down to a single Ethernet cable.

Field documentation

Fused imaging pinpoints which component heats up: the visible channel confirms the exact equipment while the thermal channel quantifies the anomaly.

DLD-TS — TECHNICAL SPECIFICATIONS

Thermal detector640 × 512, 384 × 288 or 256 × 192
Visible camera1920 × 1080
Fill lightNear-infrared, 30 m range
Image modesPicture-in-picture, dual-light fusion and other display modes
Measurement modes10 real-time moving points, 10 areas and 3 lines (max/min/average); irregular-shape drawing
Temperature outputModbus RTU/TCP
Alarms1 hardware alarm input and 1 output; alarm light and buzzer connection
Video integrationONVIF Profile-S/G compatible
Power supplyPOE (Power over Ethernet)
ProtectionIP66 outdoor enclosure with lightning and surge protection

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote