Partial Discharge Monitoring

CONTINUOUS PD MONITORING ∙15+ CHANNELS

DYNAMIC RATINGS

Image: Dynamic Ratings monitoring unit with blue front panel, power supply, main monitor and PD monitor modules, green terminal blocks, Ethernet ports and status LEDs.

RMM

ROTATING MACHINE MONITOR

C/ María Barbeito, 14Contact Contact T [+34] 982 20 99 20
27003, Lugo, SpainT [+34] 982 20 99 20 info@amperis.com | www.amperis.com

Continuous partial‐discharge monitoring that protects the reliability and uptime of your rotating machines.

Your system's uptime matters

Image: Turbo‐generators and large motors: critical monitored assets

The Rotating Machine Monitor (RMM) raises plant reliability, lifting uptime and trimming maintenance costs. It watches partial discharge continuously while also logging and correlating the machine's operating dynamics, capturing every industry‐standard PD graphical result together with the quantities defined by IEC. Motors are critical assets: IEEE and EPRI studies attribute up to 40% of electrical‐origin failures on high‐voltage motors to stator‐insulation problems, most of them triggered by partial discharge in windings and cables. The RMM reports on that insulation's health in medium‐ and high‐voltage motors, generators and VFD‐driven machines.

Features & functions

Built around innovative sensors, monitoring hardware and controls for acquisition, analysis and diagnostics, the RMM works alongside asset‐management tools so operators draw the full value from online and partial‐discharge monitoring. It brings a complete range of advanced noise‐cancellation techniques — including the removal of cross‐coupled signals — and tracks the operating context that matters: ambient and winding temperature, humidity and load.

Optimal design

At least fifteen independent, simultaneously monitored and user‐configurable channels deliver an industry‐leading signal‐to‐noise ratio and accept PD sensors of any brand. Beyond PD, the unit reads six RTD winding temperatures, three load currents, three voltages and six user‐defined 4‐20 mA inputs, and can run motor‐current‐signature analysis to reveal broken rotor bars in induction machines. Up to two years of data are held on a first‐in, first‐out (FIFO) basis.

Independent operation, open communications and reuse of existing sensors — for fast, low‐disruption deployment.

Communication & implementation

Image: Open stainless steel enclosure housing a blue monitoring module with wiring, terminal blocks and an earth conductor.

Effective communication

The RMM keeps asset‐management and maintenance teams informed in good time. It can work on its own, with no PC connected, yet still provides a broad set of built‐in interfaces — Ethernet, USB and RS‐485 — using ModBus as the standard protocol, with DNP‐3 available on request.

Easy implementation

Designed to run with PD sensors that are already installed, the RMM avoids the purchase, engineering and installation costs of fitting new ones. Placed inside an approved enclosure, it can also be deployed in a wide variety of locations.

Optional hazardous‐location enclosure

For demanding sites, a hazardous‐location enclosure is offered in 316 stainless steel — the best choice for aggressive environments — with a gasketed flange whose O‐ring seats inside the cover bolts to seal the unit. It is certified to Class I, Division 1 (Groups B, C, D); Class II, Division 1 (Groups E, F, G); and Class I, Zone 1, IIB T4.

Optional hazardous‐location enclosure (316 stainless steel)

Reaching partial discharge deep in the windings — and driving a full analysis toolset.

Applications & software

Image: Detection zone: coupling capacitors + RTD‐PD module

Applications

Coupling capacitors sense partial discharge only near the machine terminals; the RTD‐PD module reaches the discharge that occurs deep inside the windings, where the RTDs already respond to its high‐frequency content. Used together, the two techniques widen the detection zone. Whatever the machine, four parameters are recommended for correlation with PD: winding temperature, ambient temperature, relative humidity and load current. A typical arrangement for turbos, small hydro sets and motors uses two sets of coupling capacitors — one at the line terminals and one in the isolated‐phase bus duct, at least two metres apart for a time‐of‐arrival measurement; large hydro generators often need two to four sets, one per parallel‐phase group, with coaxial‐cable lengths trimmed for correct time‐of‐arrival calibration.

Software package

The bundled Windows software drives portable and continuous insulation‐monitoring systems across generators, motors, switchgear, cables, bus duct and transformers, letting users configure the instrumentation, download and store data, and analyse it with a full toolset.

Test results are presented in every industry‐standard format; all standard quantities can be trended and several channels compared on one screen.

Graphic results

Image: Phase-resolved partial discharge pattern: clusters of dots on the positive and negative half-cycles over the reference sine wave.
Image: Three-dimensional graph showing two clusters of peaks, the highest in red and yellow over a blue base.
Image: Software polar diagram with a cloud of measurement points grouped symmetrically around the centre.

2D phase resolved

3D phase resolved

Polar phase resolved

Magnitude vs. phase angle across the AC cycle

Phase‐resolved view with pulse count as third axis

The distribution mapped around the phase circle

Image: Trend graph with several coloured data series fluctuating over time.
Image: Pulse height distribution Pulse count at each discharge magnitude

Trend

Evolution of the quantities over time, by channel

Product specifications — Rotating Machine Monitor (Dynamic Ratings RMM)

Detector characteristicsArray size/format PD channels15 per module, concurrent data acquisition
Field of view/min focus distance Spatial resolutions(IFOV) Dynamic range0,79mrad or 1,13mrad 70 dB, 3 mV to 10 V, no gain adjustment
Image manage AcquisitionNETD Frame rate Measurement bandwidth@30 60Hz 1 MHz to 20 MHz
Image manageFrame rate Focus Zoom Phase resolution60Hz Auto / Manual / Motorize 1-4x electronic zoom 7.5° (power frequency)
Zoom Spectral range CCD Magnitude windows1-4x electronic zoom 1,3 million CMOS 32
Image displayCCD LCD RTD winding temperatures1,3 million CMOS 6
Image display Auxiliary inputsLCD Temperature ranges Load currents / voltages-40 3 / 3
Accuracy Measurement correction User‐defined inputs±2 or ±2% of reading, whichever is greater Auto/Manual 6 × 4‐20 mA
Mode Internal memory8 MB
Measurement Data, interface & commsImage control Color pallete Image adjustment Data storage11 pallettes changeable (Iron, Rainbow, Grey and Grey inverted, etc) t Auto/Manual adjustment of contrast and brightness ≈2 years, first‐in first‐out (FIFO)
Data, interface & commsSetup Emissivity correction User interfaceVariable from 0.01 to 1.0 PC (Windows software)
Emissivity correction Background temp adjustment Atmospheric transmission correction CommunicationsVariable from 0.01 to 1.0 Auto, according to the background temp n Automatic correction according to user input object distance, humidity and temperature Ethernet, USB, RS‐485; ModBus (DNP‐3 optional)
Power & environmentAtmospheric transmission correction Storage Card Storage Mode Power requirementn Automatic correction according to user input object distance, humidity and temperature 8G SD card, storage > 6000 Manual/automatic single-frame image storage, continuous visible, infrared video recording 90‐264 V AC (47‐63 Hz); 100‐300 V DC
Power & environmentStorage Mode IR image Single frame Operating temperatureManual/automatic single-frame image storage, continuous visible, infrared video recording JPEG, 14 bit thermal image with measurement data ‐40 °C to 70 °C (hazardous enclosure: ‐20 °C to 40 °C)
Image SaveIR image Video Visual image Single frame Mounting optionsMPEG-4 or 14 bit thermal image with measurement data JPEG Standalone, panel‐mounted, enclosure‐mounted, hazardous‐location
Enclosure & certificationsVisual image Video Voice annotation Hazardous enclosureMPEG-4 40s., saved together with the image 316 stainless steel with gasketed flange
Laser pointerImage improvement Power supply CertificationsClass I Div 1 B/C/D; Class II Div 1 E/F/G; Class I Zone 1 IIB T4
Contact Contact

Mounting options and mechanical dimensions for every configuration.

Dimensions & mounting

Standalone (S)

Panel mounted (P)

Enclosure mounted (E)

Hazardous‐location (H)

Image: Dimension drawing of a metal enclosure with door, showing dimensions A, B and C, and A + 1.5" and B + 1.5" across the mounting tabs.
Image: 1 module: 20.64 cm (8.125 in) 2: 25.72 cm (10.125 in) 3: 30.80 cm (12.125 in) 4: 35.88 cm (14.125 in)

Mounting hole A

Image: 1: 31.12 × 36.20 cm (12.25 × 14.25 in) 2: 43.50 × 43.50 cm (17.125 × 17.125 in) 3‐4: consult factory

Mounting hole A × B

Mounting hole A × B × C

1: 31.75 × 35.56 × 22.86 cm (12.5 × 14 × 9 in) 2: 46.99 × 54.61 × 27.94 cm (18.5 × 21.5 × 11 in) 3‐4: consult factory

Image: 1: 48 × 48 × 36 cm (18.89 × 18.89 × 14.17 in) 316 stainless steel; gasketed flange

Mounting hole A × B × C