Dielectric tester for gloves, blankets, hot sticks, tools and voltage indicators
A laboratory that tests gloves, boots, blankets, insulated tools, hot sticks and voltage indicators needs a 100 kV AC tester and a way to dry rubber goods after the test. The MSP-100S tests class 00 to 4 gloves, class 0 to 4 boots, blankets, mats and covers and insulated tools up to 100 kV AC, tests hot sticks at 100 kV every 300 mm up to 2.5 m and phase and voltage indicators up to 110 kV, comes with the SzS-20 drying cabinet for gloves, boots and sleeves and performs the tests per ASTM D120, F496 and IEC 60903.
Product Summary
Testing of personal protective equipment:
- Gloves - class 00, 0, 1, 2, 3 & 4;
- Boots - class 0, 1, 2, 3 & 4.
- Blankets, mats, covers - class 0, 1, 2, 3 & 4;
- Insulated tools and other electric equipment. Up to 100 kV AC;
- Hot sticks - 100kV every 300mm, up to 2.5m length;
- Phase and voltage indicator - up to 110kV.
Drying cabinet for gloves, boots, sleeves SzS-20.
Allows Testing under ASTM D120, F496 and IEC 60903 Standards.
Three-year warranty
Product Description
Dielectric Glove, Sleeve, Blanket, Hot Sticks and Tools Tester MSP-100S is designed for:
Testing of personal protective equipment:
- Gloves - class 00, 0, 1, 2, 3 & 4;
- Boots - class 0, 1, 2, 3 & 4.
Testing of insulating equipment:
- Blankets, mats, covers - class 0, 1, 2, 3 & 4;
- Insulated tools and other electric equipment. Up to 100 kV AC;
- Hot sticks - 100kV every 300mm, up to 2.5m length;
- Phase and voltage indicator - up to 110kV.
Drying cabinet for gloves, boots, sleeves SzS-20.
Allows Testing under ASTM D120, F496 and IEC 60903 Standards.
Three-year warranty
All adjustments are controlled via menu-operated microprocessor-controlled system. With selection of test voltage, current limit, and test time. Microprocessor control provides the user with menu-based system – to select the type (class, length, new or retest) of rubber items for testing. This eliminates any chance for operator error and provides an extremely fast changeover from one class to another. Current readings of all positions are conveniently displayed on control panel, and peak current during the test is saved on screen, for easy record keeping.
MSP-100S key data
- Personal protective equipment: the MSP-100S tests class 00, 0, 1, 2, 3 and 4 gloves and class 0, 1, 2, 3 and 4 boots.
- Blankets and tools: class 0 to 4 blankets, mats and covers, and insulated tools and other electrical equipment up to 100 kV AC.
- Hot sticks: the MSP-100S tests them at 100 kV every 300 mm, up to 2.5 m long.
- Indicators: the MSP-100S tests phase and voltage indicators up to 110 kV.
- Drying: SzS-20 drying cabinet for gloves, boots and sleeves.
- Standards: testing per ASTM D120, ASTM F496 and IEC 60903.
- Control: menu-driven microprocessor to select test voltage, current limit, test time and the type of rubber item (class, length, new or retest); current readings of all positions are displayed on the panel and the peak current is saved on screen.
- Warranty: the MSP-100S carries a three-year warranty.
Frequently asked questions
Up to what voltage does the MSP-100S test phase and voltage indicators?
Up to 110 kV. The same MSP-100S tests insulated tools and other electrical equipment up to 100 kV AC and hot sticks at 100 kV every 300 mm up to 2.5 m long.
What does the MSP-100S offer for drying gloves after the test?
The SzS-20 drying cabinet, for gloves, boots and sleeves. Gloves are tested in classes 00 to 4 and boots in classes 0 to 4, per ASTM D120, F496 and IEC 60903.