AMZC-304: loop impedance meter

Micro-ohmmeters & loop impedance metersSee the comparison

AMZC-304: loop impedance meter

Compact short-circuit loop impedance meter with IP67 housing

Loop impedance
0.13…1999 Ω per EN 61557
Measuring current
Max. 13.3 A at 400 V
Short-circuit current
Calculated: 0.110 A…40.0 kA
Continuity
±200 mA per EN 61557-4
Voltage and frequency
0…500 V; 45.0…65.0 Hz
Memory and interface
990 results; Bluetooth

Which model do you need? Talk to an engineer

+34 982 20 99 20

ISO 9001 · ISO 14001 · ISO 45001

Checking that the protective devices of a low-voltage installation clear a short circuit in time means measuring the fault loop impedance and knowing the prospective short-circuit current, ideally without taking the installation out of service. The AMZC-304 measures ZL-PE, ZL-N and ZL-L from 0.13 to 1999 Ω per EN 61557 with 0.01 Ω resolution and ±(5% m.v. + 3 digits), calculates the prospective short-circuit current up to 40.0 kA, measures without tripping RCDs of 30 mA or more from 0.5 Ω and verifies protective conductor continuity with ±200 mA, in an IP67 housing that stores 990 results and sends them over Bluetooth.

AMZC-304 key data

  • Loop impedance: ZL-PE, ZL-N and ZL-L from 0.13 to 1999 Ω per EN 61557 (1.2 m leads), 0.01 Ω resolution and ±(5% m.v. + 3 digits), with the RS and XS components.
  • Measuring current: the AMZC-304 drives a maximum of 7.6 A at 230 V and 13.3 A at 400 V, in three 10 ms pulses.
  • No RCD tripping: ZL-PE from 0.5 Ω in circuits with RCDs of IΔn ≥ 30 mA, in the 180 to 270 V range, with accuracy from ±(6% m.v. + 5 digits).
  • Short-circuit current: calculated from the impedance and the rated voltage and displayed from 0.110 A to 40.0 kA (up to 24.0 kA in no-trip mode).
  • Continuity: protective and equipotential conductors with ±200 mA per EN 61557-4, from 0.12 to 400 Ω with ±(2% m.v. + 3 digits); low-current resistance up to 1999 Ω.
  • Networks: 220/380, 230/400 and 240/415 V, with an operating range of 180 to 270 V (ZL-PE, ZL-N) and 180 to 460 V (ZL-L), 45 to 65 Hz; voltmeter from 0 to 500 V.
  • Memory and communication: the AMZC-304 stores 990 results and transfers them to the PC over Bluetooth.
  • Ruggedness: IP67 housing, CAT IV 300 V (CAT III 600 V) with double insulation, four AA batteries or NiMH accumulators and operation from 0 to +50 °C.

Advantages

Loop with 0.01 Ω resolution

The standard-current 2p measurement covers 0.13 to 1999 Ω per EN 61557 with ±(5% m.v. + 3 digits), using up to 13.3 A at 400 V (7.6 A at 230 V) in three 10 ms periods.

Without tripping RCDs

The low-current mode measures ZL-PE from 0.5 Ω in circuits protected by RCDs of 30 mA or more, with the installation in service and no outages.

Fault current at a glance

From the impedance and the rated voltage, the meter calculates the prospective short-circuit current from 0.110 A to 40.0 kA and separates the resistance RS and reactance XS components.

Continuity per EN 61557-4

Protective and equipotential connections are verified with a ±200 mA current from 0.12 to 400 Ω, and resistance with low current up to 1999 Ω.

Applications

  • Verification of short-circuit protection in residential and office buildings.
  • Industrial plants with fault currents up to 4.4 kA.
  • Circuits protected by RCDs, measured without causing trips.
  • Continuity checks of protective and equipotential conductors.

About the product

The AMZC-304 is one of the most compact loop meters in its class: 220 × 102 × 61 mm and about 0.8 kg, powered by four AA batteries or NiMH accumulators. It works in 220/380 V, 230/400 V and 240/415 V networks (180…460 V range) at 45…65 Hz, measures voltage from 0 to 500 V and frequency, and supports measurement with the L and N conductors swapped.

It complies with the EN 61557 series and the CAT IV 300 V (CAT III 600 V) category with double insulation. The 990-result memory downloads to the computer over Bluetooth, where the reader software archives and documents the verifications; the WS-05 UNI-Schuko adapter speeds up measurements at socket outlets.

Available accessories: WS-05 adapter with angular UNI-Schuko plug, 1.2 m test leads (red, blue and yellow), pin probes, crocodile clip, carrying case, straps, batteries and a factory calibration certificate; optionally the WS-03, WS-04 and WS-07 adapters, AGT three-phase adapters from 16 to 63 A and 5, 10 and 20 m leads.

Technical specifications

Loop impedance0.13…1999 Ω per EN 61557; resolution from 0.01 Ω
No-trip mode (RCD)From 0.5 Ω in circuits with RCDs ≥30 mA
Measuring currentMax. 13.3 A at 400 V; 7.6 A at 230 V (3 × 10 ms)
Short-circuit currentCalculated: 0.110 A…40.0 kA; RS and XS components
Continuity±200 mA per EN 61557-4; 0.12…400 Ω
Voltage and frequency0…500 V; 45.0…65.0 Hz
Memory and interface990 results; Bluetooth
SafetyCAT IV 300 V (CAT III 600 V); IP67
Loop accuracy±(5% m.v. + 3 digits); no-trip mode from ±(6% m.v. + 5 digits)
Operating range180…270 V (ZL-PE, ZL-N); 180…460 V (ZL-L)
Power supply and environment4 AA batteries or NiMH accumulators; 0…+50 °C

Frequently asked questions

How accurate is the AMZC-304 and what current does it use to measure the loop?

With standard current the AMZC-304 measures from 0.13 to 1999 Ω per EN 61557 with 0.01 Ω resolution and ±(5% m.v. + 3 digits), driving a maximum of 7.6 A at 230 V or 13.3 A at 400 V in three 10 ms pulses. In no-trip RCD mode it measures from 0.5 Ω with accuracy from ±(6% m.v. + 5 digits).

Can it measure with long leads or with a socket adapter?

Yes. The AMZC-304 range per EN 61557 starts at 0.13 Ω with the 1.2 m leads, 0.17 Ω with 5 m, 0.21 Ω with 10 m, 0.29 Ω with 20 m and 0.19 Ω with the WS-01, WS-05 and WS-07 adapters, always up to 1999 Ω.

Which networks can it measure in?

In 220/380 V, 230/400 V and 240/415 V networks with working voltages from 180 to 460 V and a frequency of 45 to 65 Hz.

Does it trip RCDs while measuring?

Not in RCD mode: the low-current measurement avoids tripping RCDs of 30 mA or more, keeping the installation in service.

Does it calculate the prospective short-circuit current?

Yes. From the measured impedance and the rated voltage it indicates 0.110 A to 40.0 kA, with the resistance and reactance components.

Does it withstand site conditions?

Yes. The sealed IP67 housing, backlit keyboard and AA battery power make it fit for outdoor and harsh environments.

Videos

AMZC-304 (5:18)
AMZC-304: compact fault loop impedance meter for 230/400 V installations, from 0.13 to 1999 Ω, with a mode that does not trip RCDs of 30 mA and above, and continuity at 200 mA. How it is connected for each fault loop and for continuity, and why a meter this small is sealed to IP67. Watch the video with its transcript

AI-generated video. The information must be validated by an Amperis engineer.

Downloads

PDFDownload the catalogue · AMZC-304: loop impedance meter214 KB · EN
Electrical test instrument selector Tell us what you need to measure and on which installation —insulation, earth, loop, RCDs, micro-ohmmeter and other measurements— and get the instrument that covers your specification, with its standard accessories and the ones worth adding. You can send us the selection with the technical report attached. Open the selector and find my equipment Close the selector

Undecided between several models? Compare them side by side: Insulation resistance testers compared · Multifunction installation testers compared · Earth resistance testers compared · Loop impedance testers compared

More in Micro-ohmmeters & loop impedance meters

See all →

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote