Insulation resistance testers compared

Technical data of the 12 units of this type offered by Amperis, row by row. Tick «Compare» on two or three to see them side by side, copy the link or print the comparison.

Insulation resistance testers compared
AMIC-10: insulation resistance meter AMIC-10K1: insulation tester up to 10 kV AMIC-15K1: insulation tester up to 15 kV AMIC-2505: insulation resistance tester AMIC-30: megohmmeter insulation tester AMIC-5005: insulation tester up to 5 kV AMIC-5010: insulation resistance tester AMIC-2501 No product page on this site AMIC-2511 No product page on this site AMIC-5 No product page on this site AMIC-5001 No product page on this site AMIC-5050 No product page on this site
Test voltage50, 100, 250, 500 or 1000 V50 – 1000 V in 25 V steps; 1 – 10 kV in 50 V stepsUp to 15 kV; step (SV) and ramp (RT) modes500 / 1000 / 2500 V50 – 1000 V, in 10 V steps or fixed values50 – 1000 V in 10 V steps; 1 – 5 kV in 25 V steps50 – 5000 V; 10 V steps to 1 kV, 25 V steps above100 – 2500 V in 100 V steps10 – 2500 V in 10 V steps or fixed: 10, 25, 100, 250, 500, 1000 and 2500 V250 or 500 V50 – 500 V in 50 V steps; 500 – 5000 V in 100 V steps50 – 1000 V in 10 V steps; 1 – 5 kV in 25 V steps
Measuring range50 kΩ to 250 MΩ (50 V) up to 1 MΩ to 10.0 GΩ (1000 V), according to EN 61557-210 MΩ to 40.0 TΩ per EN 61557-2 (UN = 10 kV)50 kΩ to 40.0 TΩ per IEC 61557-2 (UN = 15 kV)Up to 2 TΩ per IEC 61557-2 (UISO = 2500 V, IISO = 1 mA)Up to 100 GΩ (UN = 1000 V); ±(3% m.v. + 8 digits)50 kΩ to 15.0 TΩ per EN 61557-250 kΩ – 15 TΩ per IEC 61557-2 (UISO = 5 kV)Up to 1 TΩ acc. to IEC 61557-2 (IISO = 1 mA)Up to 2 TΩ acc. to EN IEC 61557-2 (IISO = 1.6 mA)250 kΩ – 1000 MΩ (250 V); 500 kΩ – 1999 MΩ (500 V), acc. to IEC 61557-2Up to 5 TΩ acc. to IEC 61557-2Up to 20 TΩ acc. to IEC 61557-2 (UISO = 5 kV)
DiagnosticsNot stated on the product pagePI, DAR, SV, DD; timer up to 99'59''Diagnostics: PDI, IR, DAR, PI, SV, RT, DD; breakdown voltage
Interference immunity: Up to 1550 V and 10 mA; filters of 10 – 200 s
T1, T2, T3 within 15 / 60 / 600 sNot stated on the product pageDiagnostics: PI, DAR, SV, DD; timer up to 99'59''
Step voltage (SV): Sequences up to 5 kV; steps of 30 s to 5 min
PI, DAR, Ab1, Ab2, SV, DD; timer up to 99'59''Ab, DAR, PI; T1, T2, T3 at 15 / 60 / 600 sAb1, Ab2, DAR, PI; T1, T2, T3 within 1 – 600 s
On-screen charts; correction to reference temperature
Not stated in the documentationDAR, PI; T1, T2, T3
RampTest (ramp up to ~1 kV/s) and breakdown voltage up to 5 kV
PI, DAR, Ab1, Ab2, SV, DD; timer up to 99'59''
Fault location by burn-through
Digital filters of 10 – 200 s; interference immunity up to 1550 V and 8 mA
Test currentNot stated on the product page1.2 mA, 3 mA or 5 mAUp to 10 mA; approx. 150 W HV inverterNot stated on the product pageNot stated on the product page1.2 mA or 3 mANot stated on the product pageNot stated in the documentation≤2 mAUp to 1.4 mAShort-circuit current up to 1.5 mA1.2 mA, 3 mA or 6 mA; HV inverter of approx. 30 W
AccuracyNot stated on the product page±(3 % m.v. + 10 digits); ±(12.5 %) at 40 TΩ±(3 % m.v. + 10 digits); ±(12.5 %) at 40 TΩ±(3% m.v. + 20 digits)Not stated on the product page±(3 % m.v. + 10 digits); ±(10 %) at 15 TΩ1.2 mA or 3 mA±(3% m.v. + 20 digits)±(3% m.v. + 20 digits)From ±(3% m.v. + 8 digits)±(3% m.v. + 20 digits); ±(4% m.v. + 50 digits) at 1 – 5 TΩ±(3% m.v. + 10 digits); ±(12.5% m.v. + 10 digits) at 10 – 20 TΩ
Other measurementsContinuity: 0.10 to 1999 Ω, according to EN 61557-4, current >200 mA
Low voltage and resistance: 0 to 1999 Ω, current <15 mA
Capacitance: 1 nF to 9.99 μF
DC and AC voltage: 0 to 600 V; 45 – 65 Hz
Voltage measurement: DC and AC, 0 to 750 V; 45 – 65 Hz
Capacitance measurement: 1 nF to 49.99 µF; ±(5 % m.v. + 5 digits)
Continuity: Protective connections per EN 61557-4, >200 mA
Not stated on the product pageVoltage measurement: AC/DC 0 – 600 V; 45 – 65 HzContinuity RCONT: >200 mA per EN 61557-4; 0.10 – 1999 Ω
Voltage measurement: AC/DC 0 – 600 V; 45 – 65 Hz
Capacitance: 1 nF – 9.99 µF, measured during RISO
Voltage measurement: DC and AC, 0 to 600 V; 45 – 65 Hz
Capacitance measurement: 1 nF to 49.99 µF; ±(5 % m.v. + 5 digits)
Digital filters: 10 / 30 / 60 s; immunity up to 500 VContinuity: >200 mA in both directions; 0.00 – 999 Ω
DC and AC voltage: 0 – 750 V; 45 – 65 Hz
Continuity: 200 mA; 0.10 – 999 Ω
DC and AC voltage: 0 – 1500 V; 45 – 65 Hz
Capacitance: 0 – 9.99 µF
Temperature: -40.0 – 99.9 °C (optional probe)
Surge protective device (SPD) testing and EPA area measurements
Low-voltage resistance: 0.0 – 1999 Ω, current <10 mA; beeper below 10 Ω
AC/DC voltage: 0 – 600 V, automatic detection
Built-in flashlight
DC and AC voltage: 0 – 750 V; 45 – 65 HzDC and AC voltage: 0 – 1500 V
Capacitance: 0 – 49.99 µF
Temperature: -40.0 – 99.9 °C (optional probe)
Memory and communicationsNot stated on the product pageUSB and Bluetooth; backlit 5.6-inch LCDAutomatic saving; USB and BluetoothNot stated on the product page990 cells; wireless USB receiver990 banks (11880 records); USB or wireless>200 mA per EN 61557-4; 0.12 – 999 Ω990 cells (nearly 12,000 results); USB9999 results; USB; 5" graphic LCDNot stated in the documentation990 cells (11,880 records); USB990 cells (10,000 records / 8 MB); USB and Bluetooth; 5.6" graphic LCD
Power supply4 AA alkaline batteries or Ni-MH battery set90 – 265 V, 50/60 Hz mains or battery packsPower supply: 14.8 V Li-Ion battery; mains 90 – 260 V, 50/60 Hz
Autonomy: At least 1000 RISO measurements per charge
9.6 V NiMH battery pack with mains chargerNot stated on the product page90 – 265 V, 50/60 Hz mains or battery packNot stated on the product page9.6 V 2 Ah NiMH battery; charging during measurement; 90 – 264 V, 50/60 Hz mains adapter; approx. 800 measurements10.8 V 3.5 Ah Li-Ion battery; min. 600 RISO measurements2 × AAA 1.5 V batteries or 1.2 V NiMH AAA rechargeables; 14 h (250 V) / 11 h (500 V)9.6 V 2 Ah NiMH battery; charging during measurement (90 – 264 V mains or 12 V car socket); approx. 800 measurements13.2 V 5.0 Ah Li-Ion battery or 90 – 260 V, 50/60 Hz mains; approx. 5 h; min. 1000 RISO measurements
Safety and protectionCAT IV 600 V; IP67CAT IV 600 V (CAT III 1000 V); IP40 (IP67 closed)Safety: CAT IV 1000 V (≤2000 m); IP67 (IP40 open)
Operating conditions: -20 to +50 °C; humidity 20 – 90 %; ≤3000 m
CAT IV 600 V (CAT III 1000 V); IP54CAT IV 600 V (CAT III 1000 V); IP67CAT IV 600 V (III 1000 V); IP54 (IP67 closed)990 cells (11 880 records); USB and BluetoothCAT IV 600 V (CAT III 1000 V); IP65; double insulationCAT IV 600 V (≤2000 m); IP65; double insulationCAT IV 600 V (CAT III 1000 V); IP65; double insulationCAT III 1000 V (CAT IV 600 V) up to 2500 V; CAT III 600 V (CAT IV 300 V) above; IP65CAT IV 600 V (CAT III 1000 V); IP67 (IP40 open); ≤3000 m
Dimensions and weight220 × 100 × 60 mm; 1 kg390 × 310 × 180 mm; approx. 7 kg390 × 308 × 172 mm; approx. 6.3 kg260 × 190 × 60 mm; 1.3 kg200 × 100 × 60 mm; approx. 0.6 kg390 × 310 × 170 mm; approx. 7 kgCAT IV 600 V (CAT III 1000 V); IP67 (case closed)200 × 150 × 75 mm; approx. 1.0 kg234 × 169 × 71 mm; approx. 1.3 kg275 × 82 × 36 mm; 338 g200 × 150 × 75 mm; approx. 1.0 kg390 × 308 × 172 mm; approx. 6.1 kg
View product →View product →View product →View product →View product →View product →View product →Request information →Request information →Request information →Request information →Request information →

Data from the specifications table of each product page and, for units without a product page, from their technical documentation. Missing data is flagged.

Request a quote for these units

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote