Continuous partial discharge monitoring compared

Technical data of the 3 units of this type offered by Amperis, row by row. Tick «Compare» on two or three to see them side by side, copy the link or print the comparison.

Continuous partial discharge monitoring compared
Dynamic Ratings RMM Rotating Machine Monitor Partial discharge detector APD-ANNUNCIATOR PD Profiler: partial discharge monitor
Designed forStator winding insulation of MV/HV motors and generators; also VFD-fedMV switchgear panels and cabinets in service; dry-type transformers and RMUsMV/HV transformers, switchgear and cables; secondary substations; cable accessories
Channels15 PD channels per module, simultaneous acquisition; coupling capacitors and RTD-PD
6 winding temperatures; 3 currents; 3 voltages; 6 × 4 – 20 mA inputs
3 acoustic and 3 high-frequency per module; TEV, acoustic (contact or airborne) and HFCT sensors (20 and 60 mm); cascaded modules8 – 20 PD channels per unit; acoustic/TEV and split-core HFCT sensors (20 or 60 mm); daisy chain
Connectivity and controlEthernet, USB, RS-485; Modbus as standard; DNP3 on requestModbus; USB; web interface; cascaded Ethernet (data and power); optional cellular modemModbus IP; MQTT; REST API; USB
Sensitivity70 dB dynamic range (3 mV – 10 V) without gain adjustment; 7.5° phase resolution40 dB dynamic range (acoustic and high frequency)Dynamic range: acoustic 60 dB; high frequency 80 dB
Bandwidth1 – 20 MHzAcoustic 30 – 88 kHz; HF 10 MHz – 1 GHzAcoustic 20 – 250 kHz; HF 3 – 80 MHz; UHF 100 – 500 MHz
Measured variablesMagnitude, pulse count, discharge intensity and phase distribution; 2D/3D patterns, polar view, pulse amplitude distribution, trends
Correlation with load, voltage and temperature; broken rotor bars (current signature); up to 2 years of data
Per-channel PD activity with noise validation; trends in web interfacePhase-resolved PrPD patterns; rating indicators; trends; geospatial view; per-channel filters and gating
Outputs and alarmsNot stated on the product pagePer-channel threshold; local LED and hardware output; remote alert via SCADA, web, SMS or e-mailLocal alarm LED; status to SCADA; internal memory for several months
Power supply90 – 264 V AC, 47 – 63 Hz or 100 – 300 V DC9 – 24 V DC; 1.2 W max.Not stated on the product page
Operating conditionsHazardous-area version in 316 stainless-steel explosion-proof enclosure-30 – 50 °C; IP65 with dust caps fittedNot stated on the product page
FormatStand-alone, panel or enclosure mountingDIN-rail or magnetic-mount module; 201 × 87 × 53 mm; 0.51 kgUnit with magnetic mounting or DIN rail; installation without outage
View product →View product →View product →

Data from the specifications table of each product page and, for units without a product page, from their technical documentation. Missing data is flagged.

Request a quote for these units

Got a test to solve? Talk to an engineer.

Tell us the asset, the voltage and the test you need, and we will propose the right instrument.

+34 982 20 99 20 Mon–Thu 09:00–14:00 · 15:30–19:00Fri 08:00–14:00 Request a quote