Fixed power analysers and energy meters compared

Technical data of the 7 units of this type offered by Amperis, row by row. Tick «Compare» on two or three to see them side by side, copy the link or print the comparison.

Fixed power analysers and energy meters compared
Analizador de redes eléctricas SHARK 200 NEXUS 1252 Powerline Analyzer Nexus 1450 Power Quality Meter Nexus 1500 wave quality analyzer Powerline analyser SHARK 100-S Powerline Analyzer NEXUS 1272 Powerline Analyzer SHARK 100
Measurement classClass 0.2 ANSI C12.20; 0.2S IEC 62053-220.06 % energy accuracy (% of reading); self-calibrating0.06 % energy (ANSI C12.20, IEC 62053-22); power quality IEC 61000-4-30 class A ed. 30.06 % energy (exceeds ANSI C12.20 class 0.1 and IEC 62053-22 0.2S); IEC 61000-4-30 class A ed. 3; PQI-A (IEC 62586-2)Class 0.2 ANSI C12.20; 0.2 % IEC 6870.06 % Wh; self-calibrating with temperature compensationClass 0.2 ANSI C12.20; 0.2S IEC 62053-22
Harmonics, flicker and transientsHarmonics to the 40th order; waveform up to 512 samples/cycle; CBEMA and SEMI F47Harmonics to the 255th order; waveform up to 512 samples/cycle, 16-bit; sub-cycle transients; CBEMA/ITIC; flicker and EN 50160 / IEC 61000-4-30 (V2 key)Harmonics and interharmonics to the 511th order (IEC 61000-4-7); flicker IEC 61000-4-15; waveform up to 1024 samples/cycle, 16-bit; EN 50160 reports; ITIC/CBEMA and SEMI F47Harmonics and interharmonics to the 511th order (IEC 61000-4-7); flicker IEC 61000-4-15; waveform up to 1024 samples/cycle, 16-bit; EN 50160 reports; ITIC/CBEMA and SEMI F47; transients up to 50 MHzTHD (V4 key)Harmonics to the 255th order; interharmonics; flicker Pst/Plt (EN 50160); sags and swells; transients; CBEMA/ITIC logTHD (V4 key)
Connectivity and controlRS485 (Modbus, DNP3) and IrDA standard; optional Ethernet (Modbus TCP/IP, DNP3, IEC 61850)4 isolated RS485 ports (one RS232) up to 115 kbaud; Modbus RTU/ASCII; DNP 3.0 level 2 plus; optional 10/100BaseT Ethernet (Modbus TCP, DNP over TCP); modem6 ports: 2 Ethernet, RS485, ANSI optical and USB; Modbus, DNP3; IRIG-B, SNTP, DNP3 time sync; 128-bit AES encryption6 ports: dual Ethernet, RS485, ANSI optical and USB; Modbus TCP/IP, DNP3 level 2 plus, IEC 61850 with GOOSE, SNMP; IEEE 1588 PTPv2; IEEE C37.118 synchrophasorsRS485 Modbus RTU; RJ45 10BaseT Ethernet or IEEE 802.11 WiFi (Modbus TCP); IrDAOptical port; 2 × RS485 up to 115 kbps; Modbus RTU/ASCII; DNP 3.0 level 2 plus; optional: 56k dial-out modem, 10/100BaseT Ethernet with web serverIrDA standard; optional RS485 (Modbus, DNP3) or 10/100BaseT Ethernet (Modbus TCP/IP)
Voltage and current inputsVoltage: 20 – 576 V L-N; 0 – 721 V L-L; current: class 10 up to 10 A; class 2 up to 2 AVoltage: 150 V L-N / 300 V L-L or 300 V L-N / 600 V L-L; current: 5 A nominal (1 A or 0.25 A on request); 5th auxiliary voltage channelVoltage: 20 – 720 V AC between inputs; current: class 2 and class 20 on the same input, dual sensing stage, pick-up at 1 mA; auxiliary voltage inputVoltage: 5 – 347 V L-N; 10 – 600 V L-L; current: 1 A (class 2) or 5 A (class 20) nominalVoltage: 20 – 416 V L-N; up to 721 V L-L; current: 1 or 5 A secondary CTs (max. 10 A)Voltage: up to 480 V phase-to-reference / 600 V L-L; current: 1 A (class 2) or 5 A (class 10/20) nominalVoltage: 20 – 416 V L-N; 0 – 721 V L-L; current: class 10: 0.005 – 10 A; class 2: 0.001 – 2 A
Memory and communications3 historical logs of over 64 parameters each; up to 4 MB (V6 key); event, alarm and I/O logs2 historical logs of up to 64 variables; out-of-limit (1 ms), CBEMA/ITIC, relay and status input logs; system event logUp to 4 GB (1.2 GB for logging); 172 parameters logged automatically; 8 configurable historical logs512 MB, 1 GB or 4 GB; virtually unlimited historical logging; COMTRADE and PQDIF exportNot stated on the product page2 historical logs of up to 64 variables; 1024 events; CBEMA/ITIC 512 events; out-of-limit, system and I/O logsNot stated on the product page
Outputs and alarmsKYZ pulse standard; 2 I/O slots: analogue outputs, pulses, relays or fibre optic; limit alarms8 high-speed digital inputs (up to 300 V DC); external modules: 4 or 8 analogue outputs 0 – 1 mA or 4 – 20 mA, 4 relays 5 A 125 V AC/DC, 4 solid-state outputs8 digital inputs; 2 pulse outputs; external modules: analogue outputs and inputs, relays, digital inputs and pulse outputs8 high-speed digital inputs; optional relay, status input and pulse output cards; setpoint controlKYZ pulse output; Wh test pulse; limit alarms (V4 key)8 digital inputs; 4 KYZ outputs; IRIG-B time sync; external analogue I/O, relay and status input modules; programmable control logicLimit alarms (V4 key)
Display and operation3-line red LED; % load barExternal LED displays or graphic touchscreenSeparate display: LED or 4.3" colour touchscreenColour touchscreen; pre-configured screens for readings, alarms and power quality3-line 0.56" red LED; % load barProgrammable backlit graphic LCD; harmonic spectrum to the 63rd order; infrared test pulse3-line red LED; % load bar; phasor diagram; front-panel or PC programming
FormatPanel: 92 mm DIN or 4" ANSI round cut-out; 12.32 × 12.32 × 10.79 cm; 0.91 kg; DIN-rail transducer versionTransducer base with separate displayTransducer base with separate display; direct retrofit of the 125x series; IP30Panel mount; 273 × 177 × 171 mm; 2.9 kg; IP30Surface wall-mount enclosure; 201 × 191 × 79 mm; 1.8 kgSocket meter (forms 9S, 36S, 45S, 9A) or switchboard casePanel: 4" ANSI round or 92 mm DIN cut-out; front 12.32 × 12.32 cm; depth 9.04 cm; DIN-rail transducer version
Power supply90 – 265 V AC / 100 – 370 V DC or 18 – 60 V DC24 – 48 V DC or 120 – 230 V AC/DC (±20 %); 20 VA max.96 – 276 V AC/DC or 18 – 60 V DC90 – 264 V AC / 100 – 240 V DC or 18 – 60 V DC90 – 400 V AC or 100 – 370 V DC; 16 VA max.Blade-powered or external: 102 – 276 V AC or 18 – 60 V DC90 – 265 V AC / 100 – 370 V DC or 18 – 60 V DC
View product →View product →View product →View product →View product →View product →View product →

Data from the specifications table of each product page and, for units without a product page, from their technical documentation. Missing data is flagged.