SF6 gas analysers compared
Technical data of the 2 units of this type offered by Amperis, row by row. Tick «Compare» on two or three to see them side by side, copy the link or print the comparison.
| Rapidox 6100 Pump Back: SF6 analyser | Rapidox 6100: portable gas analyser | |
|---|---|---|
| Measured gases | SF6, CF4, N2/air mixtures + SO2, HF, H2S, CO; H2O as dew point, µL/L or ppm | SF6, H2O, SO2, HF, CF4, H2S, CO, O2/N2 – up to 8 simultaneously |
| SF6 purity and moisture | 0 – 100 %, ±0.5 % | SF6 purity: 0 – 100 %, ±0.5 % Moisture: −60 °C to +20 °C dew point (10 – 24,000 ppmV) |
| Inlet pressure | 35 bar (gauge) | 10 bar (gauge) |
| Emissions and measuring time | Emissions: Zero: the internal 10 bar compressor returns the gas Measurement time: 2, 4, 6 or 8 min, selectable | Not stated on the product page |
| Battery life | Not stated on the product page | Over 8 h |
| Weight and protection | 20 kg, wheeled IP66 Peli case | 8.5 kg, IP66 case |
| View product → | View product → |
Data from the specifications table of each product page and, for units without a product page, from their technical documentation. Missing data is flagged.
Request a quote for these units