Skip to content
Battery charger Amperis MMF

Battery chargers and rectifiersSee the comparison

Battery charger Amperis MMF

Models
_
TYPE
Battery Charger MMF
EFFIENCY
90% (*)
POWER FACTOR
0,90 (*)
CURRENT RATINGS
From 50A to 500A.
CHARGING CURVE
User configurable.

Which model do you need? Talk to an engineer

+34 982 20 99 20

ISO 9001 · ISO 14001 · ISO 45001

Programmable universal battery charger with high-frequency IGBT hybrid technology, from a single cell to 600 V DC packs

Forming, conditioning, testing and desulphating batteries of any technology and voltage with a single unit calls for a programmable universal charger with a filtered output current and configurable charging curves. The MMF charges from a single cell up to 600 V DC at 50 to 500 A, runs on single-phase 220-240 V AC or three-phase 220 to 600 V AC, with efficiency above 90 % and power factor above 0.90 averaged over the charge cycle, and lets the user add custom curves to the factory-programmed ones.

MMF key data

  • DC output: from a single cell up to 600 V DC and 50 to 500 A; ultra-filtered, perfectly constant current with virtually zero ripple, keeping battery temperature rise to a minimum during charging.
  • Standard models: from 2-48 V / 0-50 A (A-50) to 2-48 V / 0-300 A (A-300), 2-80 V up to 150 A, 2-96 V up to 200 A, 2-120 V (F-50 and F-100), 50-200 V / 0-80 A (D-80) and 50-400 V / 0-50 A (E-50); formation versions A-00 to E-00 from 0-48 V to 0-400 V.
  • Supply: single-phase 220-230-240 V AC or three-phase 220-240, 400, 440, 480 and 600 V AC, ±10 %, 50/60 Hz ±5 Hz; efficiency >90 % and power factor >0.90, average values over the full charge cycle.
  • Applications: formation, conditioning, recovery, desulphation, regeneration and testing of lead-acid and lithium batteries, with factory charging curves and user-programmable custom curves.
  • Protection: wrong battery and reverse polarity (stays in stand-by with an error message), overload and short circuit, power-on self-test in under 10 s, shutdown within 3 s if the battery is disconnected while charging, independent safety timer and full anti-arcing protection with auxiliary wires.
  • Logging and communication: alphanumeric LCD display, LEDs, keyboard and audible alarm; internal storage of 200 cycles, expandable to 600 via USB, RS-485 port and optional wireless connection.
  • Construction: cabinet A 500 × 900 × 440 mm or B 620 × 1050 × 550 mm, IP21 as standard or IP54 optional, forced ventilation with less than 65 dBA at 1 m, operation from −10 to +50 °C up to 2000 m.
  • Standards: CE; EMC IEC EN 61000-6-2 and IEC EN 61000-6-4; safety IEC EN 50178 and IEC EN 62040-1; UL 1564, CSA 22.2 107.2-01 and cCSAus; quality ISO 9001:2015.

The most advanced technology for battery formation, conditioning, test and desulphation.

The MMF is a universal battery charger, digitally controlled and programmable.

It can operate with batteries of any type, from individual cells to complete packs, and it can be programmed to support applications of any type (Formation, Conditioning, Recovery, Desulphation and Regeneration).

It is based on a new hybrid power conversion technology, featuring an unprecedented combination of very high efficiency, unity power factor (PFC), universal capabilities and precise charge control.

The new generation of Universal Chargers

  • IGBT-HF Hybrid Converter
  • From 50 to 500 Amps
  • DC output from 12 to 700 VDC

The two parts that are combined together to compose this "Hybrid" system are:

  • Special isolation transformer, with line frequency multiplication system;
  • High frequency switchmode converter, based on IGBT technology.

The MMF features a very complete set of charging curves, and the user can complete it by programming new ones, following a very simple procedure.

Thanks to the ultra-filtered output current, this charger ensures a minimal temperature rise in the battery during the recharge process. Moreover, the MMF is suitable to charge battery types that require perfectly constant current and virtually zero ripple.

The MMF is equipped with alphanumeric display & keyboard, Charge History Logger, Programmable Real-Time Clock and Calendar, Audible Alarm and Connectivity package, compatible with wireless Battery Identification Modules and the WEB based Fleet Management System DoctorFleet.com.

Typical applications

  • Battery Formation
  • Battery Service Shops
  • Battery Testing Laboratories

Main features

  • The Most Energy Efficient technology available
  • Very Reliable design, easy maintenance
  • True Universal Charging capability: Multi-Voltage,
  • Multi-Capacity, Multi-Chemistry, from single cell to
  • Full set of standard charging curves factory
  • Possibility to Create and Save Customized Charging curves of any type
  • Intelligent electronic protection system (includes soft-start, battery polarity reversal, output short circuit and over-temperature)
  • Very quiet operation
  • Battery voltage/temperature compensation (battery temperature probe required)
  • Anti-Arcing protection (auxiliary wires required)

Optional

  • Wireless connection to DoctorFleet.com
  • Extended data-logger with USB port
  • Enclosure type IP54 or NEMA 3R (outdoor rated)
  • Submersible probe for battery temperature

Product specifications

Models

_

AC INPUT

TYPE

Battery Charger MMF

STANDARD VOLTAGES

Single-phase 220-230-240 VAC ± 10%
Three-phase 220-240, 400, 440, 480, 600 VAC ± 10%
Frequency 50/60 Hz ± 5 Hz

EFFIENCY

90% (*)

POWER FACTOR

0,90 (*)

DC OUTPUT

STANDARD VOLTAGES

From single battery cell to 600 VDC.

CURRENT RATINGS

From 50A to 500A.

CHARGING CURVE

User configurable.

PROTECTION

WRONG BATTERY AND REVERSE POLARITY

If the battery voltage is outside the acceptable limits, or the polarity is reversed, the charger remains in stand-by mode and gives error/warning message.

ELECTRONIC OVERLOAD PROTECTION

Complete protection in case of output short circuit or overload.

ANTI-ARCING

WITHOUT AUXILIARY WIRES: When the battery is connected, no arcing is generated at the connectors. If the battery is disconnected while it's being charged, arcing is possible, so it's necessary to turn off the charger before to disconnect the battery.

WITH AUXILIARY WIRES (RECOMMENDED): Full Anti-arcing protection in case of battery disconnection, even while the charge is in progress.

POWER-ON SELF-TEST

Every time the unit is powered, an automatic self-test of the power electronics and the control boards is executed in less than 10 seconds. In case of fault, the unit remains in safe stand-by mode and gives fault messages.

AUTOMATIC SHUTDOWN ON BATTERY DISCONNECTION

If the battery is disconnected while the charge is in progress, the charger turns-off automatically within 3 seconds and a specific message is saved in the Charge History Log.

SAFETY TIMER

An independent safety timer turns the charger off in case of malfunction of the main control unit.

MECHANICAL AND ENVIROMENTAL

DIMENSIONS

(W x H x D mm)

Cabinet A:
Cabinet B: 620 x 1050 x 550 (mm)

ENCLOSURE

Steel

COOLING

FORCED VENTILATION with active fan control

AUDIBLE NOISE

<65 dBA at 1 meter

ENVIROMENTAL PROTECTION

IP21 (Standard)
IP54 (Optional)

AMBIENT TEMPERATURE

OPERATION: -10 / +50 °C
STORAGE: -10 / +70 °C

ALTITUDE

<2000m
Derating according to EN62040-3

USER INTERFACE AND CONNECTIVITY

USER INTERFACE

Alphanumeric LCD Display, 5x LEDs, membrane keyboard and Audible Alarm

CONNECTIVITY

  • Dual RS-485 port for daisy chain interconnection, compatible with WEB based Fleet Management System (DoctorFleet.com)
  • Compatible with wireless Battery Identification Modules (BMOD)
  • Integrated Data-logger (200 cycles)
  • Extended Data-logger (600 cycles) with USB port (Optional)
  • Wireless card (Optional)

STANDARDS

MARKING

CE

EMC

IEC EN 61000-6-2, IEC EN 61000-6-4

SAFETY

IEC EN 50178, IEC EN 62040-1

IEC EN 62040-3

NORTH AMERICAN STANDARDS

UL 1564 ``Industrial battery chargers´´
cCSAus Listed
CSA 22.2 107.2-01 “Battery Chargers”

QUALITY

ISO 9001:2015

FORMATION MODELS

A-00: 0-48 V, 0-50 A
B-00: 0-80 V, 0-50 A
C-00: 0-96 V, 0-50 A
D-00: 0-200 V, 0-80 A
E-00: 0-400 V, 0-50 A

NOTES
(*) = Reported Efficiency and Power Factor values are AVERAGE values, measured over the entire charging cycle. Peak Efficiency and Power Factor are higher.

MMF-EUR
3x380V
MODELSVOLTAGE RANGECURRENT RANGE
MMF
A-502-48V0-50A
A-1002-48V0-100A
A-1502-48V0-150A
A-2002-48V0-200A
A-3002-48V0-300A
B-502-80V0-50A
B-1002-80V0-100A
B-1502-80V0-150A
C-502-96V0-50A
C-1002-96V0-100A
C-1502-96V0-150A
C-2002-96V0-200A
D-8050-200V0-80A
E-5050-400V0-50A

Frequently asked questions

Which charger can form and desulphate batteries of different voltages and technologies?

A programmable universal one. The MMF charges from a single cell up to 600 V DC at 50 to 500 A, comes with factory charging curves and accepts custom ones, so a single unit covers formation, conditioning, recovery, desulphation and testing of lead-acid and lithium batteries.

How does it protect against connection errors?

If the battery voltage is outside the limits or the polarity is reversed, the MMF stays in stand-by and shows an error message; if the battery is disconnected during charging, it switches off within 3 s and records the event in the charge history log, and with auxiliary wires the anti-arcing protection is complete.

Downloads

PDFDownload the catalogue · Battery charger Amperis MMF157 KB · EN Accessible version (HTML)
Battery charger and discharger selector Enter your battery's chemistry, voltage and capacity and get the charger, discharger or regeneration set that covers your specification. You can send us the selection with the technical report attached. Open the selector and find my equipment Close the selector

Undecided between several models? Compare them side by side: Battery discharge testers compared · Battery chargers and rectifiers compared · Battery testers compared